2
1
101275 Page 6
(Call factory at (800) 729-3839 for assistance)
(Cut-Off procedure if required)
CHECKING FOR DEVICE CLEARANCE
onto extrusion
Slide endcap assembly
Secure
Protect wires
during cutting
Place battery in endcap.
Battery should not contact
circuit board.
Battery
4"
10"
Max. Cut-Off
Length (L) inches
beyond edge of cut fillerplate.
Reassemble electronics
Electronics may extend
36" Unit
after cutting.
48" Unit
longer than the standard
REMOVE battery clip
for CUT-OFF lengths
Procedures for Maximum Cut Down Lengths
REMOVE electronics
prior to cut down
3
4
Caution Required-Special Handling
1
with
tape
Align fillerplate
FLUSH to extrusion
prior to cutting
CAUTION:
Check for device & door
frame clearance. If no
cut-off needed, proceed to
MORTISE CYLINDER INSTALLATION
Cut fillerplate & extrusion to
desired length*
Install battery
(where required)
3
EX
Electrified
model
Cut fillerplate & extrusion to
desired length*
Protect wires
during cutting
6 in
2 in
12 in
8 in
Secure
with
tape
2
36" Unit
Type
48" Unit
Length
Align fillerplate
prior to cutting
FLUSH to extrusion
5
cut-off length