Detex VALUE SERIES EH Installation Instructions Manual Download Page 13

ALARM OPERATIONS

Refer to SWITCH OPTIONS pages

Device features

For LBM models only:

push and hold deadlatch while
performing unit arming test.

Deadlatch detail

Deadlatch

Figure 2

Figure 1

Mortise

Cylinder

Green LED

= On

= Off

PushPad

(LHR shown)

Siren

Red LED

101275 Page 13

SPECIAL NOTES and DEFINITIONS

1. The door needs to be closed to test the unit.

2. When operating the ON/OFF switch, there is a slight delay.
3. The key is inserted and removed only in the horizontal position (home position).
4. Key function: counter clockwise (CCW) = Armed; clockwise (CW) = Disarmed.
5. Arming delay mode and auto rearm timers vary by order.
6. The power needs to be removed to register changes in the slide switches.

a. Status Indicator (This will affect battery life)
b. Disable Auto Rearm
c. Dis Lo Bat INDicator (EH units only)

UNIT ARMING TEST:

1. Turn key counterclockwise (CCW) (key is removable after rotating back to horizontal position).

2. Red LED will flash twice, then green LED will illuminate for the 15 second delay time, then turn off.

The siren will sound three short beeps indicating the unit is armed.

3. Depress Pushpad (Siren will sound and red LED will illuminate)
4. Turn key clockwise (CW). Turns alarm off.

LOW BATTERY ALERT:

1. Siren will beep and red LED will blink at approximately 45 second intervals when battery is low.

DOGGING FEATURE: (non-fire rated units only)

1. Depress Pushpad.

2. While holding Pushpad depressed, turn key clockwise (CW). Pushpad should remain depressed.

(Key is removable after rotating back to horizontal position)

3. Unit is now disarmed.

STATUS INDICATOR

1. Slide the switch to ON and apply power.

2. If the unit is armed, the red LED will blink every 3 seconds.
3. If the unit is disarmed, the green LED will blink every 3 seconds.

Disable AUTO REARM

1. When the unit is in full alarm and the door closes, the alarm will shut off after 2 minutes.

Care and Maintenance:

The Detex Value Series® devices are designed to provide many years of maintenance free service

under normal usage. Periodically inspect and lubricate the unit to extend its life.

Summary of Contents for VALUE SERIES EH

Page 1: ...04357 1 3 0 P N 104355 1 3 0 P N 100783 P N PP 5567 Hex Nut 9V Battery Hex Key P N 100450 Endcap Bracket U S PATENT NUMBERS 6009732 6205825B1 6532777B2 INTERNATIONAL PATENT NUMBER PCT6009732 P N 101844 P N 101822 Endcap P N 101821 INSTALLATION INSTRUCTIONS FOR DETEX VALUE SERIES V40 RIM PANIC HARDWARE FV40 RIM FIRE EXIT HARDWARE AND H MODELS HURRICANE Detex Corporation 302 Detex Drive New Braunfel...

Page 2: ...or Must Not be Warped Surface strike possible Mortise strike recommended least 3 screw threads Door Must Not Sag X Door Skin X Blind Rivet Nut X Doors and frames with walls having a structural thickness metal skin plus reinforcement or solid wood to engage less than 3 full screw threads are considered unreinforced for hardware CHECK BEFORE STARTING Unreinforced Doors Use Sex Nuts and Bolts Fastene...

Page 3: ...e 3 8 Exterior Door Face Pencil Tools Required Used on Strike Hook Mounting Holes Unreinforced Hollow Metal Doors Unreinforced Hollow Metal Doors Recommended on Fire Rated Wood and Used on Mounting plate and Endcap Mounting Holes 7 or 13 64 9 64 25 or 9 64 10 24 Tap 1 4 20 Tap Metal Applications Used on 99 Strike Center Mounting Hole Used to Mount Centercase Cover and Endcap Used to Fasten Centerc...

Page 4: ...crews Fasten loosely with 6 label temporarily if necessary see outside trim instructions Trim input hole 5 Slide 99 strike locator into mounting plate if using a 98 strike see 98 STRIKE INSTALLATION page 1 holes Mounting plate holes 2 For 1 4 20 machine screws drill 7 holes For 14 self drilling screws no pilot holes necessary For sex nuts drill 3 8 holes see fastener table and strike holes Mark mo...

Page 5: ...eel off backing to expose tape IMPORTANT Install Pushpad Wrap by snapping in place Verify wrap is secured 3 Position cam as shown Insert centercase into slots of centercase mounting plate depress pushpad rotate toward door 1 MUST BE INSTALLED to mounting plate Fasten rim device with 1 4 20 x 1 4 PPH 2 DOOR ...

Page 6: ...MOVE battery clip for CUT OFF lengths Procedures for Maximum Cut Down Lengths REMOVE electronics prior to cut down 3 4 Caution Required Special Handling 1 with tape Align fillerplate FLUSH to extrusion prior to cutting CAUTION Check for device door frame clearance If no cut off needed proceed to MORTISE CYLINDER INSTALLATION Cut fillerplate extrusion to desired length Install battery where require...

Page 7: ...ed a 7 pin mortise cylinder and cylinder collar not included length with spacers provided Adjust for LONGER cylinder Be careful when installing fillerplate assembly not to damage cable MORTISE CYLINDER INSTALLATION PRECAUTIONARY NOTE See View A 1 Longer cylinder Cylinder collar optional see note 3 Detex p n ECL 1595 2 CAUTION Tighten with hand tools only Do not overtighten View A Install cable ass...

Page 8: ... assembly Note Endcap Bracket must bottom out on extrusion DO NOT REMOVE NYLON SPACER ON BACK OF BRACKET see HARDWIRE TRANSFER OPTIONS page For 1 4 20 machine screws drill 7 holes For 14 self drilling screws no pilot holes necessary For sex nuts drill 3 8 holes Install 2 6 32 FH Screws IMPORTANT 4 With pushpad assembly level secure the endcap bracket to door by tightening the factory installed sel...

Page 9: ...device to mounting plate and door with 1 4 20x1 machine screws drill 7 holes or 14 self drilling screws center screw strike engagement BEFORE Align the 99 strike with Firmly tighten screws the latchbolt marking and drilling for Check device function and use shim if necessary 3 Note 2 Mark and drill center hole 9 64 for 10 24 machine screws No pilot hole necessary for 10 self drilling screws see fa...

Page 10: ...ned off with key Unit sounds alarm as long as door is open Extended bypass is enabled Alarm turns off 2 minutes after door is closed Auto Rearming Feature Setting Status Description Note AC power must be applied Table 3 EH models only Disable Auto rearm On factory set Off Disable Low Battery Table 2 Status Description The Device gives no indication of armed or disarmed status Status Indicator On O...

Page 11: ...r green LED every 3 seconds Disable Auto Alarm Switch selections must be made before applying power EH wiring detail Figure 2 101275 Page 11 Disable Low Battery Disable Auto rearm Status Indicator No battery or leads on device Jumper On L9SI factory presets On J1 Protect wires P1 Figure 1 STATU S INDICA TOR Status ON AUTO REAR M ON Disabl e Dis Lo Bat Dis Lo Bat ...

Page 12: ...sfer is recommended VALUE SERIES FLEX CONDUIT INSTALLATION hand tight Fasten until 3 Drill 7 8 hole through center guide 1 1 2 Hole through the inside door face Adjust for handing 4 2 LHR shown 1 2 Hole through the inside door face HARDWIRE TRANSFER OPTIONS EH and EHxR models Power Transfer Wire chase through door Electric Hinge Endcap Prep p n PT 5 Power Transfer Endcap Prep Wire chase through do...

Page 13: ... will flash twice then green LED will illuminate for the 15 second delay time then turn off The siren will sound three short beeps indicating the unit is armed 3 Depress Pushpad Siren will sound and red LED will illuminate 4 Turn key clockwise CW Turns alarm off LOW BATTERY ALERT 1 Siren will beep and red LED will blink at approximately 45 second intervals when battery is low DOGGING FEATURE non f...

Page 14: ...ng to microswitch Status indication switch is in off position Dead or weak battery Dead latch not in proper position 1 4 20 screws not installed L9 option ordered Install new battery LED s should flash and the siren beep once Secure battery correctly Set switch to defalut and reconnect power Check outside trim if applicable See trim instructions Lubricate spring Remove battery power from unit Slid...

Page 15: ...es as necessary 7 for 1 4 20 machine screws For 14 self drilling screws no pilot hole necessary 7 64 for 6 32 machine screws 9 64 for 6 sheetemtal screws see fastener table 99 strike For mounting hole locations use Strike Locator Template provided DRILL CHART Strike hook Mullion post STRIKE HOOK INSTALLATION Door Door Shield if necessary Shim if necessary 98 Strike 98 STRIKE INSTALLATION Align the...

Page 16: ...617 X Catalog No SSK3 Tamper Kit Security Kit Sex Nut Catalog No 94 Security screws p n 102212 1 Catalog No 95 Standard screws p n 102212 2 Double Door Strike Kit Narrow Stile Door Kit Optional Accessories Catalog No GB2 Glass Bead Kit 40 series p n 101644 Glass Bead Kit 1 4 20 X 1 1 2 Screw bits provided Splice Kit may be used with either 3 0 or 4 0 units Catalog No NSK1 p n 101879 1 628 Finish C...

Reviews: