104884 Page 13
Level device before installing endcap bracket
Ensure that device does not require cutting (see Step 10g on next page).
Test device fuction after installation of endcap is complete by depressing & releasing pushpad.
Action should be smooth with full return of pushpad and latch travel.
STEP 10:
HANG DOOR / ASSEMBLE DEVICE TO DOOR
Mark & drill holes for endcap bracket scews
10a
Install screws & lockwashers
2 places
COMPLETE BACKPLATE MOUNTING
10d
INSTALL ENDCAP BRACKET
10f
INSTALL DOOR ONTO FRAME PER MANUFACTURER'S SPECIFICATIONS
*
If using sexnuts, install
here.
or
or
If using sexnuts, install
here.
*
10c
REFER TO TRIM INSTRUCTIONS AT THIS TIME, IF APPLICABLE.
10b
10e
INSTALL DEVICE TO BACKPLATE
Right Hand Reverse
(RHR)
If link is not in uppermost position on the centerlift,
carefully remove "E" clips and reposition link on
top pin of the centerlift and replace "E" clips.
Verify carriage moves up and down smoothly when
pushpad is depressed and released.
Rehanding procedure
if required
HANDING INDICATOR
ON CENTERLIFT
Left Hand Reverse
(LHR)
MOVE LIFT PIN & SETSCREW TO
BOTTOM POSITION ON CARRIAGE.
LIFT PIN
MUST
BE ON
BOTTOM
Remove setscrew then liftpin which
screws out of the back.
NOTE: LINK MUST ALWAYS
BE IN TOP POSITION
setscrew
liftpin
Liftpin protruding from back of centercase
MUST
be inserted
BETWEEN
these two tabs.
Door OPEN position,
latches RETRACTED
Install device to backplate & fasten with 2 screws.
Depress pushpad appropriate
amount to line up liftpin with tabs.