1 - 12
Description varix 200/varix 14 (DECT)
1 Description
Environmental
conditions
The following classes have been specified:
- Climatic environmental conditions : 3K3
- Biological environmental conditions : 3B1
- Chemically active agents : 3C2
- Mechanically active agents : 3S2
Operating location
The system is designed for operation in fixed, weather-protected locations in accordance
with IEC 721, 3-3, Edition of April 1990.
Power supply
Each main module has its own power supply unit which provides the power for all hardware
modules in the respective rack.
- Mains input voltage: 230 Vac, +10 % … -15 %
- Mains frequency: 50 … 60 Hz
- Protection class: 1 in accordance with EN 60950
- Cooling: natural convection
- Operating protective earth: protective earth contact of 230 V mains outlet
Designation
Climatic conditions
Operation
Transportation
Long-term storage
Ambient temperature
+5 °C ... +40 °C
-25 °C ... +55 °C
-25 °C ... +55 °C
Relative humidity
20 % ... 70 %
5 % ... 85 %
5 % ... 85 %