MANUAL MODE OF OPERATION

The Automatic Mode is very easy and operative mode. But the MANUAL MODE of 
operation will give you much more sensitivity and stability of operation. While in 
Automatic Mode press the AUTO button. On the Operative Screen the symbol A for 
Automatic Mode will change to the symbol M - Manual Mode of operation.

Then you should press the TUNER button, so that you could tune the detector in the 
Manual Mode. Lets remind you again that the coil should be on operational height over 
the ground’s surface - 3-6 inches.

On the screen will appear the inscription for Automatic Tuning of the detector. For 
some seconds the detector will finish the process of AUTO TUNING. The ticking rate is 
1-3 ticks per second - it is chosen by the manufacturer as universal, and appropriate 
for the most conditions of searching. 

Summary of Contents for SSP-5100 G

Page 1: ...SSP 5100 G...

Page 2: ...dle sector A magnetometer is built in there making possible the unique discrimination of your detector Now join all the tubing elements as shown on Figure 1 After the assembly position the coil on ope...

Page 3: ...the loudspeaker of the detector Your detector is now ready for searching ATTENTION If you are close to metal object the cursor will continue to move from max to min positions unable to stop at a cert...

Page 4: ...while resetting as explained above the graphics will reach a lower level and the value on the screen will be as in the described example 48 Note If you are moving the coil correctly at a constant oper...

Page 5: ...ton On the Operative Screen the symbol A for Automatic Mode will change to the symbol M Manual Mode of operation Then you should press the TUNER button so that you could tune the detector in the Manua...

Page 6: ...f the detector No matter whether you have increased or decreased the ticking rate you ll have to press the DETECT button Immediately upon this the processor will save the setting of the ticking rate y...

Page 7: ...ding the unnecessary digging of the unwanted shallow ferrous targets The detector is set in a way to discriminate only in the surface arable layer of the ground As it happens often the hoards of coins...

Page 8: ...work with headphones then he could be forced to decrease the sound s volume this could be made by pressing the VOLUME button in front of this button on the operative screen is inscribed the current le...

Page 9: ...r operation in heavily mineralized grounds Mind that with the MAX setting of the DELAY the detector loses a little bid of its sensitivity With every change of the DELAY settings on the display will ap...

Page 10: ...o the wall socket The detector starts charging But to be able to see the process press ON OFF button If the battery is not charged on the screen will appear a text BATTERY CHARGING BATTERY HAS BEEN CH...

Page 11: ...stant operational height of the searchcoil and you do not pass over a metal object Note that the intensity of the signal is 0 When you operate the detector in areas with electromagnetic interferences...

Page 12: ...rous target Small shallow low magnetic ferrous target Small shallow strongly magnetized ferrous target With the graphics above we have shown only some more typical cases In the practice the graphical...

Page 13: ...ng Frequency 100 Hz Sound Range 0 2Hz 2 0KHz Battery Rechargeable 1800mA 12V Charger Input 110V AC 60Hz Charger Output 17V DC Battery Charging Time empty max 10 hours Depth Control for Maximized Detec...

Page 14: ......

Reviews: