MANUAL MODE OF OPERATION

If you like the preset level of the ticking rate and find it appropriate for your needs, press 
the DETECT button to enter the operational screen and start searching. 
If you want to change the ticking rate you could make it by pressing DEPTH or TUNER 
buttons. Note that the DEPTH and TUNER buttons have an ARROW like form and 
function. You could increase or decrease the ticking rate by pressing the right arrow 
(TUNER) button or left arrow (DEPTH) button. 
For a higher sensitivity increase the ticking rate. But have in mind that the increasing of 
the ticking rate too much won’t give you any more sensitivity, it could even worsen the 
quality of detector’s operation. 
There are cases when the detector becomes unstable, due to high mineralization or 
electromagnetic interferences nearby. In such cases you could decrease the ticking rate, 
pressing the left arrow (DEPTH) button. This will increase the stability of operation, but will 
decrease significantly the sensitivity of the detector.
No matter whether you have increased or decreased the ticking rate you’ll have to press 
the DETECT button. Immediately upon this the processor will save the setting of the 
ticking rate you have chosen and will keep it, no matter the changes in the ground 
conditions or the changes of the operational height of the detector’s  coil.
Have in mind, that if you sharply change the operational height of the coil, the ticking rate 
will change sharply, and the processor will need about ten seconds to return to the ticking 
rate you have chosen. If you do not want to wait for this, press one of the RESET buttons.
NOTE: If you are over a metal target while pressing a RESET button this could eliminate 
the target!
You could check at every time the level of tuning,
looking at the right bottom end of the display - the
current level of tuning is inscribed in %. May be it is
good to know that when you are on the field and you
tune the detector and the processor choose a lower
value in percentage, this will mean  that the soil’s 
mineralization is higher. If you tune the detector in the
town, the lower percentage value will mean that you
are near to metal objects. In this case you’ll have to find a clear from metal objects place.

Immediately after that on the display appears an inscription for manual tunning. 

Summary of Contents for SSP-5100 G

Page 1: ...SSP 5100 G...

Page 2: ...dle sector A magnetometer is built in there making possible the unique discrimination of your detector Now join all the tubing elements as shown on Figure 1 After the assembly position the coil on ope...

Page 3: ...the loudspeaker of the detector Your detector is now ready for searching ATTENTION If you are close to metal object the cursor will continue to move from max to min positions unable to stop at a cert...

Page 4: ...while resetting as explained above the graphics will reach a lower level and the value on the screen will be as in the described example 48 Note If you are moving the coil correctly at a constant oper...

Page 5: ...ton On the Operative Screen the symbol A for Automatic Mode will change to the symbol M Manual Mode of operation Then you should press the TUNER button so that you could tune the detector in the Manua...

Page 6: ...f the detector No matter whether you have increased or decreased the ticking rate you ll have to press the DETECT button Immediately upon this the processor will save the setting of the ticking rate y...

Page 7: ...ding the unnecessary digging of the unwanted shallow ferrous targets The detector is set in a way to discriminate only in the surface arable layer of the ground As it happens often the hoards of coins...

Page 8: ...work with headphones then he could be forced to decrease the sound s volume this could be made by pressing the VOLUME button in front of this button on the operative screen is inscribed the current le...

Page 9: ...r operation in heavily mineralized grounds Mind that with the MAX setting of the DELAY the detector loses a little bid of its sensitivity With every change of the DELAY settings on the display will ap...

Page 10: ...o the wall socket The detector starts charging But to be able to see the process press ON OFF button If the battery is not charged on the screen will appear a text BATTERY CHARGING BATTERY HAS BEEN CH...

Page 11: ...stant operational height of the searchcoil and you do not pass over a metal object Note that the intensity of the signal is 0 When you operate the detector in areas with electromagnetic interferences...

Page 12: ...rous target Small shallow low magnetic ferrous target Small shallow strongly magnetized ferrous target With the graphics above we have shown only some more typical cases In the practice the graphical...

Page 13: ...ng Frequency 100 Hz Sound Range 0 2Hz 2 0KHz Battery Rechargeable 1800mA 12V Charger Input 110V AC 60Hz Charger Output 17V DC Battery Charging Time empty max 10 hours Depth Control for Maximized Detec...

Page 14: ......

Reviews: