Operation
EN
14 / 28
06/2020
Tightening status and LED reporting
Torque control with angle monitoring
1
Max. torque
2
Target torque
3
Min. torque
4
Downshift torque
5
Pset start torque
6
Angle start
7
Min. angle
8
Max. angle
Examples:
- Both torque and angle within tolerances will lead to a green LED reporting.
- Torque within tolerances and angle below tolerances will lead to red + yellow status (red LED).
For tools running in severe applications, it may happen that reports are null when the battery is low.