Model

Min. / Nominal / Max.

EPBx 14-900-4Q

4 / 12 / 14

EPBx 17-700-10S

7 / 15 / 17

EPBx 17-700-4Q

7 / 15 / 17

EPBx stands for EPB/EPBA.

Torque range (ft.lb)

Model

Min. / Nominal / Max.

EPBx 8-1800-10S

0.34 / 1.57 / 1.80

EPBx 8-1800-4Q

0.34 / 1.57 / 1.80

EPBx 14-900-10S

0.90 / 2.70 / 3.15

EPBx 14-900-4Q

0.90 / 2.70 / 3.15

EPBx 17-700-10S

1.57 / 3.37 / 3.82

EPBx 17-700-4Q

1.57 / 3.37 / 3.82

EPBx stands for EPB/EPBA.

Rated speed (rpm)

Model

with
36 V

with
18 V

EPBx 8-1800-10S

1800

900

EPBx 8-1800-4Q

1800

900

EPBx 14-900-10S

900

540

EPBx 14-900-4Q

900

540

EPBx 17-700-10S

700

400

EPBx 17-700-4Q

700

400

EPBx stands for EPB/EPBA.

Weight

Model

(kg)

(lb)

EPBx 8-1800-10S

1

2.20

EPBx 8-1800-4Q

1

2.20

EPBx 14-900-10S

1

2.20

EPBx 14-900-4Q

1

2.20

EPBx 17-700-10S

1

2.20

EPBx 17-700-4Q

1

2.20

EPBx stands for EPB/EPBA/EPBC.

The weight is given without the battery pack.

Storage and use conditions

Storage temperature

-20 to +70 °C (-4 to +158 F)

Operating temperature

0 to 45 °C (32 to 113 F)

Storage humidity

0-95 % RH (non-condensing)

Operating humidity

0-90 % RH (non-condensing)

Altitude up to

2000 m (6562 feet)

Summary of Contents for 6151569760

Page 1: ... 6151659730 EPBA 14 900 4Q 6151659740 EPBA 17 700 10S 6151659750 EPBA 17 700 4Q 6151569760 Download the latest version of this document at http www desouttertools com info 6159929410_EN WARNING Read all safety warnings and instructions Failure to follow the safety warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future referen...

Page 2: ...structions 13 How to use the tool 13 Results monitoring 16 Results collection and analysis 17 Service 18 Firmware version on tool display 18 Tool information from tool display 18 Tool test with CVIMONITOR 18 Tool identification with CVIMONITOR 18 Maintenance Instructions 18 Read before maintenance 18 Instructions for transducerized tools 19 Preventive Maintenance 19 Service alarm on tool display 1...

Page 3: ...ard tools maintenance typical for that period expressed in time operation hours or otherwise The product warranty relies on the correct use maintenance and repair of the tool and its component parts Damage to parts that occurs as a result of inadequate maintenance or performed by parties other than Desoutter or their Certified Service Partners during the warranty period is not covered by the warra...

Page 4: ...eneral overview EPBA tools are cordless pistol nutrunners They are hand held by the operator and powered by a Desoutter battery pack On delivery the tool display is protected by a password Tools are delivered with 6 Psets which are configurable from the tool display or from CVI CONFIG The last 100 results can be displayed on the computer for analysis with CVIMONITOR The last 1000 results can be di...

Page 5: ... buttons Technical data Voltage V 18 V or 36 V Output drive Model Type EPBx 8 1800 10S Sq 3 8 EPBx 8 1800 4Q Hex 1 4 F EPBx 14 900 10S Sq 3 8 EPBx 14 900 4Q Hex 1 4 F EPBx 17 700 10S Sq 3 8 EPBx 17 700 4Q Hex 1 4 F EPBx stands for EPB EPBA EPBC Torque range Nm Model Min Nominal Max EPBx 8 1800 10S 1 5 7 8 EPBx 8 1800 4Q 1 5 7 8 EPBx 14 900 10S 4 12 14 ...

Page 6: ... with 18 V EPBx 8 1800 10S 1800 900 EPBx 8 1800 4Q 1800 900 EPBx 14 900 10S 900 540 EPBx 14 900 4Q 900 540 EPBx 17 700 10S 700 400 EPBx 17 700 4Q 700 400 EPBx stands for EPB EPBA Weight Model kg lb EPBx 8 1800 10S 1 2 20 EPBx 8 1800 4Q 1 2 20 EPBx 14 900 10S 1 2 20 EPBx 14 900 4Q 1 2 20 EPBx 17 700 10S 1 2 20 EPBx 17 700 4Q 1 2 20 EPBx stands for EPB EPBA EPBC The weight is given without the batte...

Page 7: ...n degree 2 environment Indoor use only Accessories Optional accessories eDOCK 6158119760 Side handle 6153970160 Tracker 6158132600 Required accessories Battery pack 18 V 2 5 Ah 6158132660 Battery pack 36 V 2 5 Ah 6158132670 Battery pack charger 6158132700 ...

Page 8: ...E Usage recommendations for battery packs Ensure a longer service life of the battery pack Unplug the battery pack when the tool is not used Do not leave the battery pack on the charger when the charger power supply is off How to connect the tool to CVIMONITOR Plug a battery pack to the tool Connect eDOCK to the tool and to the USB port of the computer Respect the connection order Launch CVIMONITO...

Page 9: ...EN Installation 06 2020 9 28 How to install optional accessories Refer to the user manual dedicated to the accessory available at https www desouttertools com resource centre ...

Page 10: ...reverse button Right button Left button Validate Save Quit Pset The sound is disabled The sound is enabled The battery pack is full The battery pack is low How to disable the passwords On delivery passwords are enabled 1 by default Pset and Maintenance passwords are used to protect settings against hazardous changes A red padlock is displayed on the top line of the main screen Press this button du...

Page 11: ...disable all password protections The procedure is the same to set up a new Maintenance password Sound torque unit Sound The tool can emit sounds to alert the operator in case of problems or events that may happen during the tightening operation Sounds can be set for the following topics tightening out of tolerances calibration procedure preventive maintenance low battery hardware failure maintenan...

Page 12: ...trol with angle monitoring or Angle control with angle monitoring Target torque The torque value to reach Target angle The angle value to reach Min max torque Torque values which define the min max torque tolerances Min max angle Angle values which define the min max angle tolerances Abort angle Safety angle value to stop the tool Abort torque Safety torque value to stop the tool Start torque This...

Page 13: ... tool How to select the Pset to run Go to the main screen Select the Pset to run Press this button during 2 seconds Press this button to reach Pset Go to Enable tick the box to enable this Pset save and validate Starting the tool Fit the tool with a suitable socket Select the appropriate Pset Hold the tool by means of the handle and apply to the fastener to be tightened WARNING Risk Of Injury As t...

Page 14: ...wnshift torque 5 Pset start torque 6 Angle start 7 Min angle 8 Max angle Examples Both torque and angle within tolerances will lead to a green LED reporting Torque within tolerances and angle below tolerances will lead to red yellow status red LED For tools running in severe applications it may happen that reports are null when the battery is low ...

Page 15: ... Angle threshold 5 Pset start torque 6 Min angle 7 Target angle 8 Max angle For tools running in severe applications it may happen that reports are null when the battery is low Reporting LEDs 1 Red 2 Green 3 Yellow How to read the tightening report LED color Description Action to do Green Accept report None ...

Page 16: ...fication on tightening benches Ergostop allows a smoother tool stop to reduce the torque reaction on the operator When delivered this function is disabled Go to the main screen Press this button during 2 seconds Go to Ergostop Use the buttons to enable or disable the function save and validate How to wake up EPBA tools The tool display switches off automatically after 2 minutes of inactivity Press...

Page 17: ...ults collection and analysis Connect the tool to a PC by using the eDOCK device Launch CVI ANALYZER to collect and display the last 1000 results CVI ANALYZER CVI ANALYZER is intended to analyze and import export tightening data with results curves filters profiles Test for 90 days free of charge CVI ANALYZER 1 user 6159276960 CVI ANALYZER 5 users 6159276970 CVI ANALYZER 25 users 6159276980 ...

Page 18: ...lick Start audio test The tool emits a sound The green tick displayed indicates the function is working properly Tool identification with CVIMONITOR Click this icon Click Tool identification Go to the bottom of the screen and click Read tool A green tick indicates the reading is successful Maintenance Instructions Read before maintenance WARNING Connection Hazard The tool can start unexpectedly an...

Page 19: ...f tightenings refer to the table below depending on which occurs sooner Maintenance frequency 500 000 tightenings Service alarm on tool display An alarm can be displayed when service is required This icon is displayed One of the service levels is displayed see below When no service is required none is displayed A sound is heard It is possible to set 3 service levels Level Number of tightenings Ser...

Page 20: ...ble drift of the tool torque or after any change of tool element In the manual mode the standard procedure is executed Measurements and values are typed manually by the operator The equipment required is as follows Tool equipped with a torque transducer in line CVIMONITOR Delta measuring unit Click this icon Click Tool calibration The standard procedure is as follows 1 Select the Pset to execute 2...

Page 21: ...run during around 1 minute and will stop automatically Click Stop motor align to stop the process before the end Release the trigger Declaring fixed accessories A fixed accessory mounted on a tool must be declared in this screen Click this icon Click Tool identification Select the type of accessory and fill in the parameters Click Write to tool It is mandatory to calibrate the tool equipped with t...

Page 22: ...ection 1 Change the direction of the rotary selector 2 Verify that the rotary selector is in correct position or not damaged I205 Torque settings 1 Invalid Torque setting torque is greater than tool characteristics 2 Check Pset settings with the tool characteristics I206 Speed settings 1 Invalid speed setting speed is greater than tool characteristics 2 Check Pset settings with the tool maximum sp...

Page 23: ... problem occurs again contact your Desoutter representative for sup port E018 Torque out of range 1 The target torque value is above the tool maximum torque 2 Check Pset settings with tool characteristics E029 The battery is empty 1 The battery back is discharged The tool cannot tighten 2 Recharge the battery pack E031 Battery error 1 Abnormal battery voltage The tool cannot tighten 2 Recharge the...

Page 24: ...outter representative for support E227 Motor stalled 1 Motor stalled could be missing phase wrong motor tune or power electronics failure 2 Try once again 3 If the problem occurs again contact your Desoutter representative for support E228 Drive error 1 Software failure 2 Restart the system 3 If the problem occurs again contact your Desoutter representative for support ...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...icles Off Road General Industry Desoutter offers a comprehensive range of Solutions tools service and projects to meet the specific demands of local and global customers in over 170 countries The company designs develops and delivers innovative quality industrial tool solutions including Air and Electric Screwdrivers Advanced Assembly Tools Advanced Drilling Units Air Motors and Torque Measurement...

Reviews: