background image

This Manual is applicable to the following products  

 

Revised March 29th 2012 

LD 300 starting from S.N. ____ 

Pag 4

.

 

6. LOCAL MENU 

 

 

PGM PORT

  

For Firmware Upgrade

 

  FUNCTION 1

  

Scrolling UP / Increases value “function key” 

ENTER

 

Select / Confirm  

  FUNCTION 2

 

Scrolling DOWN / Decreases value “function key” 

Display 

When the push button are not used for more than 15 
seconds the display will go OFF. It will go ON again 
anytime a push button is activated. 

DMX Presence  

Shows the presence of DMX (LED lit = DMX present) 

 

DEFAULT SETTINGS ARE INDICATED IN BOLD LETTERS ON THE FOLLOWING TABLE: 

 

The following are the BASIC FUNCTIONS and COMMANDS that are provided on the LOCAL MENU of the LED 
FRESNEL. The unit is provided with a USER MENU accessible instantly on the product.  
The unit has also a SERVICE MENU that is only accessible through a PASSWORD and is reserved for QUALIFIED and 
TRAINED PERSONNEL: 

 

1st MENU  
Displayed 

(

scrolling with the

 

 and the 

 buttons)

 

2nd MENU  

Displayed 

(after pressing the 

X

 that stands for 

ENTER

)

 

Explanation of Each MENU FUNCTION 
 
 

 

 

DMX ADDRESS 

 

This Function is to SET the 

DMX address

 from 

1

 to 512 (Product is delivered with 

default settingof the DMX address at 1) 

Once the 

C001

 is displayed, act on the 

 button to increase the address to the 

desired value.  
Temporary push will increment the value by 1, if the button is kept pushed the 
increment on numbers is getting fast. 

Once the desired Address number is accomplished press 

X

 (“ENTER”) to make it 

active

 

 

 

LOCAL DIMMING CONTROL 

 

This Function is to 

LOCALLY DIM the LED INTENSITY

 from 0 to 100% (Product is 

delivered with default setting of the DIMMER at 0). 
The intensity goes in increments of 1/100% so the display will show 

000%

 with the 

dimmer at 0% and FULL with the dimmer at 100%. 
Temporary push will increment the value by 1/100, if the button is kept pushed the 
increment on numbers is getting fast. 
Once the desired Lighting Level is accomplished and it is wanted to leave that level 
and go to other functions of the MENU, press “ENTER”.

 

 

 

LOCAL OR REMOTE CONTROL SETTINGS 

 

The LED Fresnel has the facility to block the LOCAL DIMMING SETTING and 
maintain it when the POWER is turned first OFF and than ON again. 
This allows for the LIGHT to be TUNED and FOCUSED locally and its dimming level 
can be blocked, so that for instance a system lighting a SET can be operated by a 
remote switch or simple brakers by TURNING POWER ON. 
The relevant menu to access this function is CTRL, to enter in this menu press 

X

 

(“ENTER”), it is than possible to select either 

DMX

 or AUTO by acting on the 

 or 

 

button and than press 

X

 (“ENTER”) again. The machine is set to 

DMX

 as default. 

 

 

In 

DMX

 mode: the Fixture accepts DMX control….if in this mode the local 

DIMMING CONTROL is SET to a level the Light behaviour will follow the HTP 
(Highest Takes Precedence) modality, in other words it will keep the local 
DIMMING setting until the DMX level of the specific channel will be higher, from 
that level onwards the DMX level will take precedence. In this condition if the 
DMX connection is removed, the light will keep the last level….until power is 
ON. It will reset and Start at 0after Power OFF and ON again. 

 

In AUTO mode: the light will ignore any DMX control. In this mode any local 
dimming setting will be maintained and will be automatically recalled after power 
off, when turning the power on again.

 

 

 

 

TEMPERATURE 

 

This function Displays in real time the LED ARRAY Case temperature in °C.  
When pressing Enter again you exit from the temperature display. 
 
The steady state TEMPERATURE of the ARRAY reaches approx. 55°C after many 
hours of continuous operation with an ambient temperature of 25-30°C. 
 
The Thermal Handling of the LED is Automatically handled by the local electronics and 
the LED will operate until the ARRAY temperature reaches 80°C, that anyway is still 
way within the prescribed maximum nominal prescribed by the ARRAY manufacturer 
that is 105°C. 
 
In case the ARRAY temperature reaches 80°C the unit will automatically turn off. 
 
Even in extreme Ambient temperature conditions the LED ARRAY shall never reach 
the 80°C limit. 
 
The above protection threshold is there to protect the LED ARRAY from stressed 
working conditions in case some other failures or specially critical working conditions 
are causing an over-temperature. 

 

 

Summary of Contents for LED MAGIS 40W

Page 1: ...and leadership in design innovation and manufacturing of lighting products for the professional Entertainment Industry means you can depend upon the quality of this product The LED MAGIS 40W is a compact highly efficient Fresnel lens spotlight using a LED ARRAY combined with the DE SISTI Patented optical system to optimize the photometric performances of LED ARRAYS when utilized in combination wit...

Page 2: ...rated for 20A max 4 SAFETY INSTRUCTIONS Professional use This luminaire has been designed for professional use and must be operated by qualified personnel only Not for residential use Grounding WARNING THIS LUMINAIRE MUST BE GROUNDED WARNING Disconnect Power CORDS before any maintenance work or opening the FUSE HOLDER Risk of serious injury Electrical connections IMPORTANT The cores in this mains ...

Page 3: ...ALLY FLAMMABLE SURFACE 5 INSTALLATION INSTRUCTIONS The following procedure should be adopted Before connecting the luminaire to the electrical mains ensure that A Earth line is present on the power socket B The mains voltage is within the rated range of the luminaire see technical data on the rating label C The front safety shield is present and in good condition It consists of a Fresnel lens made...

Page 4: ...D Fresnel has the facility to block the LOCAL DIMMING SETTING and maintain it when the POWER is turned first OFF and than ON again This allows for the LIGHT to be TUNED and FOCUSED locally and its dimming level can be blocked so that for instance a system lighting a SET can be operated by a remote switch or simple brakers by TURNING POWER ON The relevant menu to access this function is CTRL to ent...

Page 5: ...nd Circuit BASE 1 will be the Fine Dimming the third CIRCUIT BASE 2 will be the STROBE Of course the 16 bits function is useful if the corresponding circuits on the DMX LIGHTING BOARD are also set at 16 bits WARNING if the LED FRESNEL is set at 16 bits but more units are having a consecutive unitary address for instance first fixture set at Address 1 second fixture set at Address 2 and so forth th...

Page 6: ...t damp cloth 4 Check the condition of the safety shield see chapter Installation Instructions before every use 5 Check Power supply cable and DMX control cable proper conditions 10 SAFETY STANDARDS Europe The product conforms the Applicable European Directives Standards Low Voltage Directive 73 23 EEC as amended by 93 68 EEC EMC Directive 89 336 EEC as amended by 92 31 EEC by 93 68 EEC Europen Sta...

Reviews: