2.  YOKE AND ACCESSORIES ASSEMBLY 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3.  POWER AND DMX DAISY CHAIN 

 
 
 

The LED LEONARDO 40W permits both POWER and DMX DAISY CHAIN. 
In fact each Fixture is respectively equipped with: 
 
For DMX: 

 

1 XLR5 pin Panel Mount Male (DMX IN) 

 

1 XLR5 pin Panel Mount Female (DMX OUT) 

 
For Mains Supply 

 

1 20A Powercon NAC3MPA BLUE (POWER IN) 

 

1 20A Powercon NAC3MPB WHITE (POWER OUT) 

 
It is recommended to Daisy Chain a Max of 12 fixtures, even if the limitations 
imposed by DMX Standards are for an higher q.ty of units and even if the 
Powercon Connections are rated for 20A max.  

 
 
 
 

 

4. SAFETY INSTRUCTIONS 

 

 

Professional use: 

This luminaire has been designed for professional use and must be operated by 

qualified personnel only. 

Not for residential use. 

 

Grounding:  WARNING

: THIS LUMINAIRE MUST BE GROUNDED 

 

WARNING:

  Disconnect Power CORDS before  

 

any maintenance work or opening the FUSE HOLDER.  
Risk of serious injury. 

 

 

Electrical connections

IMPORTANT 

The cores in this mains lead are colored in accordance with the 

following code: 

 Europe America 
Ground 

Green & yellow

 

Green or green & yellow

 

Neutral 

Blue

 

White

 

Live 

Brown

 

Black

 

 

In case the colors of the cores do not correspond to the colors of the connection points on your plug, please 
proceed as follows: 

  the green or green and yellow core must be connected to the connection point marked with the letter E or 

with the symbol  

or colored in green or in green - yellow; 

Summary of Contents for LED MAGIS 40W

Page 1: ...and leadership in design innovation and manufacturing of lighting products for the professional Entertainment Industry means you can depend upon the quality of this product The LED MAGIS 40W is a compact highly efficient Fresnel lens spotlight using a LED ARRAY combined with the DE SISTI Patented optical system to optimize the photometric performances of LED ARRAYS when utilized in combination wit...

Page 2: ...rated for 20A max 4 SAFETY INSTRUCTIONS Professional use This luminaire has been designed for professional use and must be operated by qualified personnel only Not for residential use Grounding WARNING THIS LUMINAIRE MUST BE GROUNDED WARNING Disconnect Power CORDS before any maintenance work or opening the FUSE HOLDER Risk of serious injury Electrical connections IMPORTANT The cores in this mains ...

Page 3: ...ALLY FLAMMABLE SURFACE 5 INSTALLATION INSTRUCTIONS The following procedure should be adopted Before connecting the luminaire to the electrical mains ensure that A Earth line is present on the power socket B The mains voltage is within the rated range of the luminaire see technical data on the rating label C The front safety shield is present and in good condition It consists of a Fresnel lens made...

Page 4: ...D Fresnel has the facility to block the LOCAL DIMMING SETTING and maintain it when the POWER is turned first OFF and than ON again This allows for the LIGHT to be TUNED and FOCUSED locally and its dimming level can be blocked so that for instance a system lighting a SET can be operated by a remote switch or simple brakers by TURNING POWER ON The relevant menu to access this function is CTRL to ent...

Page 5: ...nd Circuit BASE 1 will be the Fine Dimming the third CIRCUIT BASE 2 will be the STROBE Of course the 16 bits function is useful if the corresponding circuits on the DMX LIGHTING BOARD are also set at 16 bits WARNING if the LED FRESNEL is set at 16 bits but more units are having a consecutive unitary address for instance first fixture set at Address 1 second fixture set at Address 2 and so forth th...

Page 6: ...t damp cloth 4 Check the condition of the safety shield see chapter Installation Instructions before every use 5 Check Power supply cable and DMX control cable proper conditions 10 SAFETY STANDARDS Europe The product conforms the Applicable European Directives Standards Low Voltage Directive 73 23 EEC as amended by 93 68 EEC EMC Directive 89 336 EEC as amended by 92 31 EEC by 93 68 EEC Europen Sta...

Reviews: