This Manual is applicable to the following products
Revised March 29th 2012
LD 300 starting from S.N. ____
Pag 2
.
2. YOKE AND ACCESSORIES ASSEMBLY
3. POWER AND DMX DAISY CHAIN
The LED LEONARDO 40W permits both POWER and DMX DAISY CHAIN.
In fact each Fixture is respectively equipped with:
For DMX:
1 XLR5 pin Panel Mount Male (DMX IN)
1 XLR5 pin Panel Mount Female (DMX OUT)
For Mains Supply
1 20A Powercon NAC3MPA BLUE (POWER IN)
1 20A Powercon NAC3MPB WHITE (POWER OUT)
It is recommended to Daisy Chain a Max of 12 fixtures, even if the limitations
imposed by DMX Standards are for an higher q.ty of units and even if the
Powercon Connections are rated for 20A max.
4. SAFETY INSTRUCTIONS
Professional use:
This luminaire has been designed for professional use and must be operated by
qualified personnel only.
Not for residential use.
Grounding: WARNING
: THIS LUMINAIRE MUST BE GROUNDED
WARNING:
Disconnect Power CORDS before
any maintenance work or opening the FUSE HOLDER.
Risk of serious injury.
Electrical connections
:
IMPORTANT
The cores in this mains lead are colored in accordance with the
following code:
Europe America
Ground
Green & yellow
Green or green & yellow
Neutral
Blue
White
Live
Brown
Black
In case the colors of the cores do not correspond to the colors of the connection points on your plug, please
proceed as follows:
the green or green and yellow core must be connected to the connection point marked with the letter E or
with the symbol
or colored in green or in green - yellow;