1. Installation
1.1 Introduction
Your Desert Aire CM3540 controller is designed for precise monitoring and control of air
temperature and relative humidity (RH) within a conditioned environment.
This CM3540 control system is easy to install and operate. The controller features an
internal display terminal (IDT). This display allows viewing and adjustment of the unit’s
sensors and set points. It also indicates the operating status of major components inside
of the dehumidifier. The CM3540 controller also has the ability to control auxiliary equipment
such as a customer supplied exhaust blower, outdoor air damper, and auxiliary heating
devices for optimum energy efficiency.
Most sensors and inputs have been factory-installed and wired inside of the dehumidifier.
In most cases, only connection to a remote condenser, electrical power connection and an
Ethernet connection to the facilities computer network are required. An additional sensor,
included in the control assembly, needs to be mounted in the return air duct or the zone
to be conditioned. This device senses the conditioned zone air temperature and relative
humidity to control the LW dehumidifier. Also, units with surface temperature sensors will
require additional wiring.
The control system includes a web page which allows a virtual display terminal to be
accessed from any device on the computer network. Simply browse to the IP address
assigned to the dehumidifier, enter the appropriate credentials,
[user - Desert-Aire, password - 18485] and select the DISPLAY tab. Logging is also available
from this web page.
The CM3540 controller also features optional building automation access. This includes
options for network connect ability including LONWORKS, BACnet IP, BACnet MS/TP,
ModBus RTU and ModBus IP.
1.2
Sensor Installation
The CM3540 control system is normally provided with a unit mounted combination relative
humidity and temperature sensor. This sensor provides accurate control without the problems
associated with wall mounted sensors, such as faulty readings due to hot spots or drafts.
1.2.1 Unit Mounted Sensor
This sensor is factory mounted in the return air duct upstream of any outdoor air
intakes.
Desert Aire - CM3540 Manual
Summary of Contents for CM3540 Series
Page 2: ...2 ...
Page 5: ...5 Product Warning for the State of California Desert Aire CM3540 Manual ...
Page 6: ...6 Desert Aire CM3540 Manual ...
Page 12: ...12 Desert Aire CM3540 Manual ...
Page 29: ...29 Figure 28 Figure 29 Figure 30 Desert Aire CM3540 Manual ...
Page 44: ...44 Desert Aire CM3540 Manual ...
Page 48: ...48 Figure 60 To return to the Home screen press the Esc key Desert Aire CM3540 Manual ...