A. Test Jacks:

 The shielded black test lead’s male 

SMA connector connects into the meter's female SMA 

connector, and the red test lead’s banana plug connects 

into the meter's banana jack.

B. Exponent LEDs: 

These LEDs indicate the surface 

resistance exponent value. They are color coded for 

resistance decade quick checks.

Exponent

Color

<3, 3

Yellow

4, 5, 6, 7, 8, 9, 10 Green
11, 12, >12

Red

(i.e. 8 = 10

 ohms or 100,000,000 ohms).

C. OLED Display:

 Displays the temperature, relative 

humidity, battery life, test voltage and resistance 

measurement.

D. Power Switch: 

Slide the switch to the left to power 

the meter OFF. Slide the switch to the right to power the 

meter ON.

E.  Black Pushbuttons: 

Each black pushbutton 

corresponds to the prompts on the bottom-left and 

bottom-right of the display. These buttons are used to 

access the Settings and Memory Recall menus and 

scroll up and down between menu options.

F.  Red Pushbutton:

 Corresponds to the prompts 

located in the bottom-center of the display. This button 

is used to perform tests and select menu options. Press 

and hold this button when in the Settings and Memory 

Recall menus to exit and return to the home screen. 

G. Battery Compartment:

 Open this compartment to 

install the four AA alkaline batteries needed to power 

the meter. Replace the batteries once the battery icon 

on the display is empty.

Home / Test Results Screen

H

J

L

I

K

Figure 5. Home / Test Results screen

H. Battery Life Indicator:

 Displays the approximate life 

of the meter's 4 AA alkaline batteries.

I.  Relative Humidity:

 Displays the relative humidity.

J.  Test Voltage:

 Displays the test voltage used to 

complete the measurement.

K. Temperature:

 Displays the ambient temperature.

L.  Resistance Measurement:

 Displays the resistance 

measurement in ohms (Ω).

Settings Menu

M

N

Figure 6. Settings menu

O

P

Q

M. Firmware Revision:

 Displays the meter's firmware 

revision.

N. Temperature:

 Sets the unit of measurement for 

temperature to either Fahrenheit (ºF) or Celsius (ºC).

O. Stabilization Mode:

 Sets the meter's electrification 

period setting to either Auto and Fixed Stabilization.
Auto - Enables a 15-second electrification period when 

the measured resistance is 1 x 10

10

 ohms or greater to 

maintain test accuracy.
Fixed - Complies with ANSI/ESD S4.1 and enables a 

15-second electrification period when the measured 

resistance is 1 x 10

6

 ohms or greater.

P. Beep:

 Enables and disables the audible beep when 

the meter's pushbuttons are pressed.

Q. Erase all memory:

 Erases all stored measurement 

transactions saved in the meter's memory.

Summary of Contents for Statguard Flooring D19290

Page 1: ...STM97 1 Floor Materials and Footwear Resistance Measurement in Combination with a Person A Compliance Verification Plan shall be established to ensure the Organization s fulfillment of the technical requirements of the ESD Control Program Plan Process monitoring measurements shall be conducted in accordance with a Compliance Verification Plan that identifies the technical requirements to be verifi...

Page 2: ...O INDUSTRIES INC Employee Owned Features and Components Digital Surface Resistance Meter Figure 3 Statguard Flooring D19290 Digital Surface Resistance Meter Figure 2 Statguard Flooring D19290 Digital Surface Resistance Meter Kit Figure 4 Digital Surface Resistance Meter features and components C B D E E G F A ...

Page 3: ...ings and Memory Recall menus to exit and return to the home screen G Battery Compartment Open this compartment to install the four AA alkaline batteries needed to power the meter Replace the batteries once the battery icon on the display is empty Home Test Results Screen H J L I K Figure 5 Home Test Results screen H Battery Life Indicator Displays the approximate life of the meter s 4 AA alkaline ...

Page 4: ...ctrode placements include Most commonly used area of a surface Most worn area Center of surface Furthest area from a grounded point If the surface to be measured has sections i e floor tiles garment panels place the 5 pound electrodes on different sections for Rtt measurements Clean the material s surface for test lab measurements but do not clean the surface for materials that are already install...

Page 5: ...5 pound electrodes and place the electrodes on the most commonly used area of the surface Use the 10 electrode spacer to space them 10 apart from each other The electrodes should also be 2 away from any edge and 3 away from any grounded point If the most used area is not obvious use two points near the center of the surface 4 Push the red pushbutton to perform a measurement Should the 15 second el...

Page 6: ...n cleaning instructions Per ANSI ESD S4 1 Worksurfaces The test specimens and electrodes shall be cleaned twice with a minimum 70 isopropanol water solution using a clean low linting cloth each time Note The item should then be conditioned for 72 hours minimum Figure 13 Measuring the Resistance Point to Point Rtt of floor materials Specifications Resistance Ranges 1 x 103 to 1 x 106 ohms 10 Volts ...

Reviews: