Dual-Wire Dual Operator Monitor

Installation, Operation and Maintenance

Description

The Desco 

19662

 Dual-Wire Dual Operator Monitor 

monitors two operators and two ESD worksurfaces 

eliminating the need for periodic testing and 

record keeping of wrist straps. The Dual-Wire Dual 

Operator Monitor uses low-voltage steady state DC 

continuous-loop technology to continuously monitor 

(versus pulsed or intermittent) dual-wire wrist strap 

functionality. Independent audio and visual alarm 

conditions identify the status of the worksurfaces and 

operators. Two operator remotes with 10 foot cables are 

included for use at adjacent workstations. Each monitor 

is calibrated with accepted procedures and standards 

traceable to the National Institute of Standards and 

Technology (NIST) and includes a NIST certificate.

Dual Wire Monitor Technology

Desco dual wire dual operator monitors uses a loop 

electrical resistance technology. A +5 or +8 volt test 

signal1 is generated by the monitor and placed on one 

conductor of the dual wire wrist strap. The test voltage 

is bridged to the opposite conductor through the skin of 

the wearer of the wristband and returned to the monitor. 

Resistance is monitored with a stable continuous signal 

through one conductor, across the skin of the operator, 

and returning to the monitor through the opposite 

conductor. Desco dual wire dual operator monitors 

determine that the operator’s path-to-ground is between 

the 10 or 35 megohms2 upper limit (adjustable) and 1 

megohm1 lower limit. 

1.  See Operator Test Voltage section below for pass/

fail specs. User should determine if these voltages 

can damage the device being handled. Other 

lower voltage monitoring systems may need to be 

considered.

2.  See Operator Test Range section below for pass/fail 

specs.

 

Figure 1. Desco 19662 Dual-Wire Dual Operator Monitor

  TECHNICAL BULLETIN TB-3083 

Made in the

United States of America

ANSI/ESD S20.20 section 7.3 states “Compliance 

verification records shall be established and maintained 

to provide evidence of conformity to the technical 

requirements.” Per ANSI/ESD S1.1 Annex A.3 Daily 

(wrist strap system) testing may be omitted if constant 

monitoring used.” Per ESD Handbook ESD TR 20.20 

section 5.3.2.4.4 “Typical Test programs recommend 

that wrist straps that are used daily should be tested 

daily. However, if the products that are being produced 

are of such value that knowledge of a continuous, 

reliable ground is needed, and then continuous 

monitoring should be considered or even required.”
The Dual-Wire Dual Operator Monitor and its 

accessories are available in the following item numbers:

Item

Description

19662

Dual-Wire Dual Operator Monitor

19663

Mounting Brackets

50524

Limit Comparator

50525

Replacement Operator Remote Kit, Black

50526

Replacement Operator Remote Kit, White

19262

Replacement Power Adapter, 12 VDC

Packaging

19662

 Dual-Wire Dual Operator Monitor

1  Dual-Wire Dual Operator Monitor

1  Power Adapter, 12VDC, with interchangeable plugs

  (North America, UK/Asia, Europe)

2  Operator Remotes with Attached Cables 

  (1 Black, 1 White)

2  White Mat Monitor Cords

1  Monitor Ground Cord

1  Certificate of Calibration

19663

 Mounting Brackets

2  Mounting Brackets

4  Pan Head Screws, 8-32 x 1/8"

Summary of Contents for 19662

Page 1: ...he operator s path to ground is between the 10 or 35 megohms2 upper limit adjustable and 1 megohm1 lower limit 1 See Operator Test Voltage section below for pass fail specs User should determine if these voltages can damage the device being handled Other lower voltage monitoring systems may need to be considered 2 See Operator Test Range section below for pass fail specs Figure 1 Desco 19662 Dual ...

Page 2: ... operator remote cable G Operator 1 Remote Jack Connect to the white operator remote cable H Monitored Mat 1 Terminal Monitors a worksurface mat for proper dissipative resistance and static charges Connect the white mat monitor cord here I Ground Terminal Common ground point for the monitor Connect to the green and yellow monitor ground cord J Monitored Mat 2 Terminal Monitors a worksurface mat fo...

Page 3: ...s will remain in the STANDBY condition until a wrist cord is plugged into the operator remote STANDBY mode is indicated by a blinking yellow operator LED 2 Plug a wrist strap cord not attached to the wristband into the monitored jack labeled WRIST STRAP MONITOR located on the remote This automatically activates the selected operator channel The corresponding operator LED should illuminate red and ...

Page 4: ... EMIT 50524 Limit Comparator for Dual Wire Monitors Specifications Input Voltage and Frequency External Adapter AC DC Power Adapter Power Input 100 240 VAC 50 60 Hz Power Output 12 VDC 0 50 A Cable Length 5 ft 1 5 m Operating Temperature 50 to 95 F 10 to 35 C Environmental Requirements Indoor use only at altitudes less than 6500 ft 2 km Maximum relative humidity of 80 up to 85 F 30 C decreasing li...

Page 5: ...e Desco com TB 3083 Page 5 of 5 2020 DESCO INDUSTRIES INC Employee Owned December 2020 Figure 6 Operator Remote dimensions Replacement remotes are available as Desco items 50525 and 50526 Limited Warranty Warranty Exclusions Limit of Liability and RMA Request Instructions See the Desco Warranty Desco com Limited Warranty aspx ...

Reviews: