Calibration

The Dual-Wire Dual Operator Monitor is calibrated to 

standards traceable to NIST. Frequency of recalibratrion 

should be based on the critical nature of those ESD 

sensitive items handled and the risk of failure for the 

ESD protective equipment and materials. In general, we 

recommend that calibration be performed annually.
Use the EMIT 

50524

 Limit Comparator for Dual-Wire 

Monitors to perform periodic testing (once every 6-12 

months) of the Dual-Wire Dual Operator Monitor. The 

Limit Comparator can be used on the shop floor within a 

few minutes virtually eliminating downtime, verifying that 

the monitor is operating within tolerances.
See 

TB-6542

 for more information.

Figure 5. EMIT 50524 Limit Comparator for Dual-Wire 

Monitors

Specifications

Input Voltage and 

Frequency

(External Adapter)

AC/DC Power Adapter
Power Input: 

100-240 VAC, 50/60 Hz
Power Output: 

12 VDC @ 0.50 A
Cable Length: 

5 ft. (1.5 m)

Operating 

Temperature

50 to 95 °F (10 to 35 °C)

Environmental 

Requirements

Indoor use only at altitudes 

less than 6500 ft. (2 km)
Maximum relative humidity 

of 80 % up to 85 °F (30 °C) 

decreasing linearly to 50 % 

@ 85 °F (30 °C)

Dimensions 

(Monitor)

4.4" x 4.7" x 2.1"

(112 mm x 119 mm x 53 mm)

Weight

(Monitor)

1.1 lbs. (0.5 kg)

Operator Test Range

1.91 megohms to 35 

megohms (default)

or

1.91 megohms to 10 

megohms (±10 %)

Worksurface Test 

Limit*

3.5 megohms (±10 %)

Operator Test Voltage

8 V (default) or 5 V

Worksurface Test 

Voltage

200 mV

Country of Origin

United States of America

*

The worksurface mat must have a dedicated 

conductive layer.Desco workstation monitors are not 

recommended for use with homogeneous matting.
ANSI/ESD S20.20 requires the use of a surface 

resistance meter for periodic verification of a 

worksurface’s resistance-to-ground (Rtg). Constant 

monitors may not be used as a substitute for this 

requirement.

Summary of Contents for 19662

Page 1: ...he operator s path to ground is between the 10 or 35 megohms2 upper limit adjustable and 1 megohm1 lower limit 1 See Operator Test Voltage section below for pass fail specs User should determine if these voltages can damage the device being handled Other lower voltage monitoring systems may need to be considered 2 See Operator Test Range section below for pass fail specs Figure 1 Desco 19662 Dual ...

Page 2: ... operator remote cable G Operator 1 Remote Jack Connect to the white operator remote cable H Monitored Mat 1 Terminal Monitors a worksurface mat for proper dissipative resistance and static charges Connect the white mat monitor cord here I Ground Terminal Common ground point for the monitor Connect to the green and yellow monitor ground cord J Monitored Mat 2 Terminal Monitors a worksurface mat fo...

Page 3: ...s will remain in the STANDBY condition until a wrist cord is plugged into the operator remote STANDBY mode is indicated by a blinking yellow operator LED 2 Plug a wrist strap cord not attached to the wristband into the monitored jack labeled WRIST STRAP MONITOR located on the remote This automatically activates the selected operator channel The corresponding operator LED should illuminate red and ...

Page 4: ... EMIT 50524 Limit Comparator for Dual Wire Monitors Specifications Input Voltage and Frequency External Adapter AC DC Power Adapter Power Input 100 240 VAC 50 60 Hz Power Output 12 VDC 0 50 A Cable Length 5 ft 1 5 m Operating Temperature 50 to 95 F 10 to 35 C Environmental Requirements Indoor use only at altitudes less than 6500 ft 2 km Maximum relative humidity of 80 up to 85 F 30 C decreasing li...

Page 5: ...e Desco com TB 3083 Page 5 of 5 2020 DESCO INDUSTRIES INC Employee Owned December 2020 Figure 6 Operator Remote dimensions Replacement remotes are available as Desco items 50525 and 50526 Limited Warranty Warranty Exclusions Limit of Liability and RMA Request Instructions See the Desco Warranty Desco com Limited Warranty aspx ...