background image

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

TB-3034

 Page 2 of 6

© 2013 DESCO INDUSTRIES, INC.

Employee Owned

Packaging

19276 COMBO TESTER X3

1  Combo Tester X3

1  Dual Foot Plate

1  Power Adapter, 12VDC, N. America

1  Foot Plate Cord, 6'

1  Ground Cord

1  Certificate of Calibration

19277 COMBO TESTER X3 WITH STAND

1  Combo Tester X3

1  Dual Foot Plate

1  Power Adapter, 12VDC, N. America

1  Foot Plate Cord, 6'

1  Ground Cord

19255

 Test Stand

2  Socket Head Screws, 1/4-20 x 3/4"

2  Pan Head Screws, 10-32 x 5/8"

2  Nuts, 10-32

4  Pan Head Screws, #4 x 3/4"

1  Certificate of Calibration

Features and Components

C.  Single-Wire Wrist Strap Jack:

 Insert your single-wire 

wrist cord here to test your wrist strap.

D.  Wrist Strap Status LEDs:

 Displays the wrist strap test 

results.

E.  Dual-Wire Wrist Strap Jack:

 Insert your dual-wire wrist 

cord here to test your wrist strap.

F.  12VDC Power Jack:

 Connect the included power 

adapter here to power the Combo Tester X3.

G.  Steady-State Test Switch:

 Place and hold your finger 

here to begin the test.

H.  Relay Terminal:

 Can be integrated with electronic door 

locks, lights, buzzers, etc.  It is capable of switching up to 1A 

@ 30VDC or .5A @ 125VAC.
Terminals 1 & 2 = Normally Closed

Terminals 2 & 3 = Normally Open
NOTE: All tests must pass in order for the relay to activate.

I.  Buzzer Volume Adjustment:

 Turn the trimpot clockwise 

to increase the buzzer volume and counter-clockwise to 

decrease the volume.

J.  Ground Jack:

 Insert the banana plug end of the 

included ground cord to this jack.  Connect the ring terminal 

end of the cord to equipment ground.  This connection will 

remove any static charge from the user before the test.

NOTE: Failure to correctly ground the Combo Tester X3 may 

result in damage not covered under warranty.

K.  Foot Plate Jack:

 Connect one end of the foot plate 

cable cord and the other end to the dual foot plate.

Installation

TESTER CONFIGURATION

The resistance limits for footwear and wrist strap tests are 

controlled by the DIP switches located on the left side of 

the Combo Tester X3.  Use the following tables for the DIP 

switch settings and their corresponding test values.

Footwear Resistance

DIP switches 1 and 2 control the HIGH test limit.

A

B

C

D

E

F

G

H

I

J

K

Figure 2.  Desco Combo Tester X3 features and 

components

A.  Test Limit DIP Switch:

 Use this DIP switch to configure 

the resistance limits of the tester.  See the section titled 

“Tester Configuration” for more information.

B.  Footwear Status LEDs:

 Displays the footwear test 

results.

1 2 3

Switch 1 Switch 2 HIGH Limit Resistance

ON

ON

10 Megohms (1 x 10

7

)

OFF

OFF

35 Megohms (3.5 x 10

7

)

ON

OFF

100 Megohms (1 x 10

8

)

OFF

ON

1 Gigohm (1 x 10

9

)

Switch 3 Switch 4 LOW Limit Resistance

ON

OFF

100 Kilohms (1 x 10

5

)

OFF

ON

750 Kilohms (7.5 x 10

5

)

default setting

DIP switches 3 and 4 control the LOW test limit.

Summary of Contents for 19276

Page 1: ...ods and equipment used for process monitoring and measurements The test equipment selected shall be capable of making the measurements defined in the Compliance Verification Plan Per ANSI ESD S1 1 section 6 1 3 Frequency of Functional Testing The wrist strap system should be tested daily to ensure proper electrical value Per ESD Handbook ESD TR20 20 section 5 3 2 4 2 Additional User Wrist Strap Te...

Page 2: ...r for the relay to activate I Buzzer Volume Adjustment Turn the trimpot clockwise to increase the buzzer volume and counter clockwise to decrease the volume J Ground Jack Insert the banana plug end of the included ground cord to this jack Connect the ring terminal end of the cord to equipment ground This connection will remove any static charge from the user before the test NOTE Failure to correct...

Page 3: ...4 Use the guide located on the bottom of the foot plate to route the cord out of the side This will prevent the foot plate cord from being accidentally tripped and unplugged 5 Insert the ground cord s banana plug into the ground jack located at the bottom of the tester Connect ground cord s ring terminal to equipment ground This connection will remove any static charge from the user before the tes...

Page 4: ... before the test NOTE Failure to correctly ground the Combo Tester X3 may result in damage not covered under warranty 7 Fit the dual foot plate into a position so that is flush with the front and top of the baseplate Secure the dual foot plate to the baseplate using the four included 4 pan head screws Figure 7 Securing the dual foot plate to the baseplate 8 Power the Combo Tester X3 using the incl...

Page 5: ...mproved by taking a short walk to build a sweat layer for better conductivity The Combo Tester X3 may also be used to test smocks or garments that feature a grounding mechanism for operators using a coil cord connection Figure 9 Bridging the test switch s contacts to initiate the test Calibration The Combo Tester X3 is calibrated to standards traceable to NIST Frequency of recalibratrion should be...

Page 6: ...ddress Desco will quote repair charges necessary to bring your unit up to factory standards Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED The express warranty will not apply to defects or damage due to accidents neglect misuse a...

Page 7: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Desco 19276 19277 19255 ...

Reviews: