NOTE: At 1 Gigohm high limit resistance, a dirty foot 

plate could result in a false pass.  Be sure to keep the 

foot plate clean particularly when using this setting.  

This setting is not suitable for relative humidity greater 

than 50%.

Wrist Strap Resistance

DIP switches 5 and 6 control the HIGH test limit.

DIP switch 5 must be ON (default setting) for the wrist 

strap test to be active.  The wrist strap test will be 

disabled if DIP switch 5 is set to OFF.
The LOW limit for the wrist strap test is set to 750 

kilohms and cannot be modified by the user.

INSTALLING THE 19276 COMBO TESTER X3

1.  Mount the tester at the desired location using the

  four mounting holes located in the corners of the

  yellow mounting plate.
2.  Set the Dual Foot Plate below the tester.
3.  Insert one end of the foot plate cord into the stereo 

  jack located at the bottom of the tester.  Insert the 

  opposite end of the cord into the stereo jack located 

  at the back of the foot plate.
4.  Use the guide located on the bottom of the foot 

  plate to route the cord out of the side.  This will 

  prevent the foot plate cord from being accidentally 

  tripped and unplugged.

5.  Insert the ground cord’s banana plug into the ground 

  jack located at the bottom of the tester.  Connect 

  ground cord’s ring terminal to equipment ground.  

  This connection will remove any static charge from 

  the user before the test.  

NOTE: Failure to correctly 

  ground the Combo Tester X3 may result in damage not 

  covered under warranty.

6.  Power the Combo Tester X3 using the included 

  power supply.

INSTALLING THE 19277 COMBO TESTER X3 WITH 

STAND

1.  Insert the pedestal to the baseplate with the 

  mounting bracket sloping toward the operator.  Be 

  sure to align the screw holes located at the base of 

  the pedestal.

2.  Use the two 1/4-20 socket cap screws to secure the 

  pedestal to the baseplate.

Figure 3.  Routing the foot plate cord through the foot 

plate’s guide

Figure 4.  Securing the pedestal to the baseplate using 

the 2 socket cap screws

3.  Route the ground and foot plate cords through the 

  pedestal.  Feed the cords from the bottom and have them 

  exit through the top.

Figure 5.  Routing the ground and foot plate cords 

throught the pedestal

Switch 5 Switch 6 HIGH Limit Resistance

OFF

OFF

wrist strap test disabled

ON

ON

10 Megohms (1 x 10

7

)

ON

OFF

35 Megohms (3.5 x 10

7

)

default setting

Summary of Contents for 19276

Page 1: ...ods and equipment used for process monitoring and measurements The test equipment selected shall be capable of making the measurements defined in the Compliance Verification Plan Per ANSI ESD S1 1 section 6 1 3 Frequency of Functional Testing The wrist strap system should be tested daily to ensure proper electrical value Per ESD Handbook ESD TR20 20 section 5 3 2 4 2 Additional User Wrist Strap Te...

Page 2: ...r for the relay to activate I Buzzer Volume Adjustment Turn the trimpot clockwise to increase the buzzer volume and counter clockwise to decrease the volume J Ground Jack Insert the banana plug end of the included ground cord to this jack Connect the ring terminal end of the cord to equipment ground This connection will remove any static charge from the user before the test NOTE Failure to correct...

Page 3: ...4 Use the guide located on the bottom of the foot plate to route the cord out of the side This will prevent the foot plate cord from being accidentally tripped and unplugged 5 Insert the ground cord s banana plug into the ground jack located at the bottom of the tester Connect ground cord s ring terminal to equipment ground This connection will remove any static charge from the user before the tes...

Page 4: ... before the test NOTE Failure to correctly ground the Combo Tester X3 may result in damage not covered under warranty 7 Fit the dual foot plate into a position so that is flush with the front and top of the baseplate Secure the dual foot plate to the baseplate using the four included 4 pan head screws Figure 7 Securing the dual foot plate to the baseplate 8 Power the Combo Tester X3 using the incl...

Page 5: ...mproved by taking a short walk to build a sweat layer for better conductivity The Combo Tester X3 may also be used to test smocks or garments that feature a grounding mechanism for operators using a coil cord connection Figure 9 Bridging the test switch s contacts to initiate the test Calibration The Combo Tester X3 is calibrated to standards traceable to NIST Frequency of recalibratrion should be...

Page 6: ...ddress Desco will quote repair charges necessary to bring your unit up to factory standards Warranty Exclusions THE FOREGOING EXPRESS WARRANTY IS MADE IN LIEU OF ALL OTHER PRODUCT WARRANTIES EXPRESSED AND IMPLIED INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH ARE SPECIFICALLY DISCLAIMED The express warranty will not apply to defects or damage due to accidents neglect misuse a...

Page 7: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Desco 19276 19277 19255 ...

Reviews: