background image

TB-3072

 Page 4 of 6

© 2018 DESCO INDUSTRIES INC

Employee Owned

DESCO WEST 

- 3651 Walnut Avenue, Chino, CA 91710 • (909) 627-8178

DESCO EAST 

- One Colgate Way, Canton, MA 02021-1407 • (781) 821-8370 • Website: 

Desco.com

Installation onto Micastat® Laminate

Materials Needed:

14244

 Micastat® Flush Mount Ground Inserts 

14242

 Micastat® Flush Mount Insert Tool 

09857

 10mm Socket and Rivet (100 per pack) 

2  8-32 Button Cap Screws
1.  Install the two flush mount ground inserts into the 

Micastat® laminate. Space the inserts 1-5/16" apart 

from one another. 

2.  Once the ground inserts are installed, remove the 

8-32 screws that were supplied with the kits. 

3.  Place 10mm snap sockets on top of the installed 

brass ground inserts. 

4.  Screw the 10mm snap sockets into place on the 

ground inserts using the 8-32 button cap screws. 

5.  Align the two snaps underneath the Mini Monitor 

to the two snaps on the Micastat® laminate. Apply 

downward force on the monitor once aligned to 

snap the Mini Monitor into place. 

6.  Connect the power adapter to the power jack 

located on the top-side of the Mini Monitor. Route 

the wire from the supply to a nearby AC outlet 

and plug it into the outlet. Make sure the voltage 

and frequency match those listed on the power 

supply. The Mini Monitor is now powered, and the 

Micastat® laminate is now grounded.

10mm Park Snap and 10mm Operator Jack Adapter

The 

19243

 Mini Monitor includes an interchangeable 

10mm park snap and 10mm banana jack adapter for 

operators who use wrist cords with 10mm terminations. 

Use the park snaps' knurled rims to unscrew the 4mm 

park snap from the monitor and install the 10mm park 

snap to the monitor. Plug the 10mm operator jack 

adapter into the monitor's operator jack.

Installation

1.  Remove the Mini Monitor from the carton, and 

inspect for damage. 

2.  Locate an appropriate AC outlet near the Mini 

Monitor, and test it for proper wiring and grounding 

prior to use. The Desco AC Outlet Analyzer or 

similar test equipment may be used to verify the 

outlet’s functionality. Use item number 

98132

 for 

120VAC North American outlets and item number 

98131

 for 220VAC UK outlets. 

3.  Determine the mounting location of the Mini Monitor. 

It is normally installed toward the front edge of a 

workstation where its LEDs can be visible to the 

operator. Use a blade to pierce two holes 1-5/16" 

apart from one another into the worksurface mat. 

4.  Use a Phillips screwdriver to secure the two flathead 

screws and countersunk washers through the 

worksurface mat and into the two threaded 10mm 

snaps on the bottom of the Mini Monitor. 

Figure 7. Changing the park snap on the 

19243

 Mini 

Monitor

Figure 5. Securing the Mini Monitor to a worksurface mat

5.  Connect the power adapter to the power jack 

located on the top-side of the Mini Monitor. Connect 

the wire from the supply to the tested AC outlet, and 

plug it into the outlet.

NOTE: Older revision Mini Monitors do not feature 

threaded 10mm snaps on their bottom-side. They 

require the use of push and clinch snaps to secure the 

monitor to the worksurface mat.

Summary of Contents for 19258

Page 1: ...he continuous or constant monitor The test voltage creates a sine wave that the monitor circuit compares to established patterns By monitoring the distortions or shape of the sine wave Wave Distortion Technology determines if the monitored circuit is complete the operator is in the circuit and the total equivalent DC resistance is within specifications Wave Distortion Technology produces a very fa...

Page 2: ...ashers 2 Flat Head Screw 6 32 x 1 4 1 Power Adapter 24VDC North America Plug 1 Certificate of Calibration 19243 Mini Monitor Universal Power Adapter 1 Mini Monitor 2 Countersunk Washers 2 Flat Head Screw 6 32 x 1 4 1 10mm Interchangeable Park Snap 1 10mm Operator Jack Adapter 1 Power Adapter 24VDC IEC Inlet 1 Certificate of Calibration Figure 2 North American power adapter included with the 19239 ...

Page 3: ...park a wrist strap when leaving the workstation without creating a false alarm Touch the park snap and the monitor s audible alarm will disable for approximately 10 seconds Use this time to disconnect the wrist cord from the wristband and attach it to the park snap or remove the banana plug from the jack Upon returning to the workstation and disconnecting the wrist cord from the park snap the oper...

Page 4: ...ark snap and 10mm banana jack adapter for operators who use wrist cords with 10mm terminations Use the park snaps knurled rims to unscrew the 4mm park snap from the monitor and install the 10mm park snap to the monitor Plug the 10mm operator jack adapter into the monitor s operator jack Installation 1 Remove the Mini Monitor from the carton and inspect for damage 2 Locate an appropriate AC outlet ...

Page 5: ... 2 Snap the wrist cord to the wristband 3 Plug the wrist cord into the operator jack The green operator LED will illuminate This indicates that the operator is properly grounded 4 If this does not happen examine the wrist cord for continuity or damage and the wristband to ensure that it fits securely If you have dry skin apply an approved dissipative hand lotion such as Menda Reztore ESD Hand Loti...

Page 6: ... megohms 20 Operator Test Voltage 1 2V peak to peak 1 2µA open circuit Worksurface Test Voltage 5 to 7 5V open circuit Alarm Response Time 50 ms Country of Origin United States of America This cannot be verified with standard DC test equipment The continuous monitor is an impedance sensing device and the limits are determined by the magnitude and angle of the impedance The worksurface mat must hav...

Reviews: