background image

www.desatech.com

111099-01C

12

OPTIONAL GAS LINE 

INSTALLATION

Continued

  CAUTION:  All  gas  piping 

and connections must be tested 

for  leaks  after  the  installation 

is  completed.  After  ensuring 

that the gas valve is on, apply 

soap  and  water  solution  to  all 

connections and joints. Bubbles 

forming  show  a  leak.  Correct 

all leaks at once. DO NOT USE 

AN  OPEN  FLAME  FOR  LEAK 

TESTING AND DO NOT OPER-

ATE ANY APPLIANCE IF A LEAK 

IS DETECTED. LEAK TESTING 

SHOULD BE DONE BY A QUALI-

FIED SERVICE PERSON.

Note: 

A  DESA  hood  must  be  installed  when 

using an unvented gas log set (see 

Accessories

 

on page 16).

  WARNING:  Do  not  oper-

ate an unvented gas log set in 

this fireplace with the chimney 

removed.

If you install a decorative gas appliance (vented 

gas log), the decorative gas appliance must comply 

with the 

Standard for Decorative Gas Appliance 

for Installation in Solid Fuel Burning Fireplaces, 

ANS Z21.60, Z21.84 or RG 2-72

 and shall also be 

installed in accordance with the 

National Fuel Gas 

Code, ANSI 7223NFPA 54 latest edition

.

Seal 
Opening 
with 
Refractory 
Cement

Outside of 
Fireplace

Gas 
Line 
Conduit

Repack 
Insulation

Incoming 
1/2" Black 
Iron Pipe

Side 
Firebrick 
Finished 
Side

Provide Enough Threaded 
End for Fitting Connection

Figure 20 - Gas Line Installation

 WARNING: To avoid the risk of 

damaging the fireplace materials 

and increasing the risk of spread-

ing a fire, do not use the fireplace 

to cook or warm food.

  WARNING:  If  the  fireplace 

has been used for wood burning, 

the firebox and chimney must be 

cleaned  of  soot,  creosote  and 

ashes  be  a  qualified  chimney 

cleaner.  Creosote  will  ignite  if 

heavily heated.

  WARNING:  When  using  a 

decorative  vented  gas  log,  the 

damper must be removed or per-

manently locked in the fully open 

position and the glass doors must 

be in the fully open position.

Doors Fully Closed

Fireplace Front

Doors

Fully Opened

Fireplace Front

OPERATION AND 

MAINTENANCE 

GUIDELINES

GLASS DOORS

Glass doors are optional with the fireplace. When 

the fireplace is in operation, doors must be fully 

opened or fully closed position only or a fire hazard 

may be created (see Figure 21).

Figure 21 - Glass Doors

Summary of Contents for VS42 Series

Page 1: ...g approved to ANS Z21 60 Z21 84 or RGA 2 72 standards or for use with a vent free gas log heater approved toANS Z21 11 2 standard A DESA hood must be installed when using a vent free log heater see Accessories page 16 This wood burning fireplace complies with UL127 CAN ULS S610 M87 standard as a FACTORY BUILT APPLIANCE FOR CANADA The authority having jurisdiction such as the municipal building depa...

Page 2: ...f any component part not manufac tured or approved by DESAin combination with a DESA fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local building codes as to the particular requirements concerned with the installation of all factory built fireplaces WARNING Do not install a fireplaceinsertinthisboxunless the manuf...

Page 3: ...NOT LESS THAN 12 1 AIRSPACE TO COMBUSTIBLE COMBUSTIBLE WALL BOARD 0 TO MATERIAL NO COMBUSTIBLE MATERIAL ON FACE SIDEWALL TERMINATION SQUARE CHASE TOP GAS LINE KNOCK OUT AIR KIT KNOCK OUTS ROUND TOP TERMINATION GAS LINE KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE 8 125 12 625 14 25 45 25 41 48 42 24 8 39 16 25 29 5 2 5 10 625 1 12 2 5 8 125 6 75 10 625 12 25 48 0 625 36 22 5 ...

Page 4: ...inimum Maximum Chimney Height for Outdoor Installation The minimum height of the chimney measured from the base of the fireplace to the flue gas outlet of the termination is 8 feet minimum of 4 feet of chimney pipe sections required for outdoor installation FRAMING 1 Frame the opening for the fireplace using the dimensions shown in Figures 1 and 2 2 If the fireplace is to be installed directly on carp...

Page 5: ...tension from shifting and seal gap between the fireplace frame and hearth extension with a non combustible material see Figure 3 WARNING Hearthextension is to be installed only as shown in Figure 3 FIREPLACE INSTALLATION Continued Figure 3 Hearth Extension Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember Protector Ember Protector Seal Gap Hearth ...

Page 6: ...ed end up Press down on each pipe section until the lances securely engage the hem on the fire placestarter Thewirewillassuretheproperspacing between the inner and outer pipe sections VENTING INSTALLATION OPTIONAL OUTSIDE AIR KIT MODEL AK4 AK4F The installation of an outside air kit should be per formed during the rough framing of the fireplace due to the nature of it s location Outside combus tion ...

Page 7: ...pipe between supports return elbow or 12S 8DM is 6 of angle run Maximum of two 6 angle run sections per chimney system see Figure 7 4 All pipe connections between the offset and return must be secured with two screws on the outer pipe only see Figure 9 page 8 Do not penetrate the inner stainless OFFSET RISE CHIMNEY LENGTH A B 48 36 24 18 12 4 3 8 16 3 8 ELBOW SET ONLY 9 3 4 25 1 2 1 12 3 4 30 3 4 ...

Page 8: ...of 8 PENETRATING THE ROOF To maintain a 1 clearance to the pipe on a roof with a pitch a rectangular opening must be cut 1 Determine the center point through which the pipe will penetrate the roof 2 Determine the center point of the roof Pitch is the distance the roof drops over a given span usually 12 A 6 12 pitch means that the roof drops 6 for each 12 one measure horizontally down from the roof...

Page 9: ...hing Cone Underlap Shingles at Bottom Overlap Shingles Top and Sides Only Figure 13 Flashing Installation Storm Collar Installation SC1 or SC2 Place storm collar over pipe and slide down until it is snug against the open edge of the flashing see Figure 14 Use SC1 for all round terminations and SC2 for all terminations with slip sections Apply waterproof caulk around the perimeter of the collar to p...

Page 10: ...re 16 Note If a decorative shroud is to be installed contact the manufacturer for specifications 10 FOOT RULE All flue gas outlet chimney terminations must extend a minimum of 3 feet in height above the highest point where it passes through the roof and must be at least 2 feet above the highest point of the roof that is within a horizontal distance of 10 feet see Figure 17 24 Min 24 Min 18 Min Typ F...

Page 11: ...add height Provide sufficient gas line into fireplace chamber for fitting connection see Figure 20 page 12 Note Secure incoming gas line to wood framing to provide rigidity for threaded end Figure 19 Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1 2 Dowel 4 Repack insulation around gas line and into sleeve op...

Page 12: ...in accordance with the National Fuel Gas Code ANSI 7223NFPA 54 latest edition Seal Opening with Refractory Cement Outside of Fireplace Gas Line Conduit Repack Insulation Incoming 1 2 Black Iron Pipe Side Firebrick Finished Side Provide Enough Threaded End for Fitting Connection Figure 20 Gas Line Installation WARNING Toavoidtheriskof damagingthefireplacematerials andincreasingtheriskofspread ingafir...

Page 13: ...for the purpose of installing a vented or vent free decorative gas appliance incorporating an automatic shutoff de viceandcomplyingwiththeStandardforDecorative GasAppliances for Installation in Vented Fireplaces ANSI Z21 60 or American Gas Association draft re quirementsforGasFiredLogLightersforWoodBurn ing Fireplaces Draft NO 4 dated August 1993 OPERATION AND MAINTENANCE GUIDELINES Continued If y...

Page 14: ...11099 01C 14 ILLUSTRATED PARTS BREAKDOWN WOODBURNING FIREPLACE MODELS S42 S42H S42R S42RH VS42 1 AND VS42H 1 9 26 16 33 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37 38 36 28 29 24 23 15 ...

Page 15: ...Pivot Clip 2 34 20090 Spring Clip 2 35 20280 Top Spacer 4 36 21171 Conduit Plate Cover 4 37 21379 Gas Conduit 2 38 21380 Gas Conduit 2 PARTS AVAILABLE NOT SHOWN 106625 01 Home Owner s Guide 1 Not a field replaceable part KEY NO PART NO DESCRIPTION QTY 9 107812 03 Left Refractory Textured White Brick 1 108169 03 Left Refractory Textured White Herringbone Brick 1 107812 02 Left Refractory Textured Re...

Page 16: ... 30 OFFSET AND RETURN ANTI DRAFT SHIELD ROUND TOP TERMINATION ONLY 30E 8DM STORM COLLAR ROOF FLASHING BI FOLD GLASS DOOR 0 TO 6 12 PITCH V6F 8DM 6 12 TO 12 12 PITCH V12F 8DM ANTIQUE BRASS FINISH GA6053 POLISHED BRASS FINISH GA6052 BLACK PAINTED FINISH GA6050 BDO42 BLACK FINISH BDO42B BRUSHED BRASS FINISH BDO42P PLATINUM FINISH ADJUSTABLE HOOD REQUIRED WHEN INSTALLING A VENT FREE GAS LOG IN THIS FI...

Page 17: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________...

Page 18: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________...

Page 19: ...______________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _______________________________________...

Page 20: ...2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 www desatech com NOT A UPC 111099 01 Rev C 09 05 111099 01 ...

Reviews: