www.desatech.com
113133-01C
15
iNsTallaTioN
Continued
Red
Red
Fan Switch
(Auto/Off/On)
Blue
Blue
Thermostat
Switch
(N.O.)
Green
White
Green
White
On
110/115
V.A.C.
Blower
Motor
Black
Off
1
2
3
Auto
Figure 20 - Wiring Diagram For Blower
Accessory Built-In Installation
3
2
1
O
F
F
P
ILO
T
O
N
H
I
L
O
Blower Bracket
Assembly
Screw
Wire Harness
Switch
Plate
Switch
Power Cord
Outlet Receptacle
(not included)
Remote/ Blower
Bracket
Clamp Connector
(not included)
3. A licensed electrician must follow the wiring
diagram to connect incoming electrical supply
to fan kit wiring harness (see Figure 20).
4. Plug power cord to outlet receptacle (not
provided) as shown in Figure 19. Wind the
extra power cord and tie with plastic wire
strap (see Figure 19). Set power cord bundle
between the remote/blower bracket and outer
casing, away from the burner.
5. Test to make sure blower is working properly.
6. Reinstall upper louver beginning with bottom
screws (see Figure 15, page 14) and close
lower louver.
Extension Cord
Use extension cord if needed. The cord must have
a three-prong, grounding plug and a three-hole re
-
ceptacle. Make sure cord is in good shape. It must
be heavy enough to carry the current needed. An
undersized cord will cause a drop in line voltage.
This will result in loss of power and overheating. Use
a No. 16 AWG cord for lengths less than 50 feet.
Figure 19 - Installing Blower Bracket Assembly
Plastic Wire Strap Wire Harness
Lower Louver Door
Figure 18 - Installing Switch Plate to
Remote/Blower Bracket
Remote/
Blower
Bracket
Switch
Plate
Screw
For Built-In Installation
WARNING: A licensed elec-
trician must connect the wiring
harness to electrical supply
following all local codes. electri
-
cian must provide a clamp on the
box cover to secure the wiring.
Wiring should be routed through
the bushing in the hole on the
outer casing of fireplace.
1. Install snap bushing from blower kit into
one hole on rear of remote/blower bracket
(see Figure 19). The other hole is for a strain
relief clamp (not supplied) to secure incoming
electrical supply.
2. Follow steps 2 through 6 in
Installing Blower
Accessory
, page 14.