background image

18

105647

UNVENTED NATURAL GAS FIREPLACE INSERT

DESA INTERNATIONAL

For more information, visit www.desatech.com

OBSERVED PROBLEM

Burner does not light after ODS/pilot is lit

Delayed ignition burner

Burner backfiring during combustion

Slight smoke or odor during initial operation

Moisture/condensation noticed on windows

Heater produces a whistling noise when
burner is lit

White powder residue forming within burner
box or on adjacent walls or furniture

Remote does not function (GHRC and
GHRCTA Series only)

REMEDY

1. Clean burner (see Cleaning and Mainte-

nance, page 21) or replace burner orifice

2. Contact local natural gas company
3. Replace burner orifice
4. Reconnect leads (see Wiring Diagram,

page 20)

5. Replace battery in transmitter and re-

ceiver

1. Contact local natural gas company
2. Clean burner (see Cleaning and Mainte-

nance, page 21) or replace burner orifice

1. Clean burner (see Cleaning and Mainte-

nance, page 21) or replace burner orifice

2. Replace damaged burner
3. Replace gas control

1. Check burner for dirt and debris. If

found, clean burner (see Cleaning and
Maintenance
, page 21)

2. Replace gas control
3. Problem will stop after a few hours of

operation

1. Refer to Air for Combustion and Venti-

lation requirements (page 4)

1. Turn control knob to LO position and

let warm up for a minute

2. Operate burner until air is removed from

line. Have gas line checked by local
natural gas company

3. Observe minimum installation clear-

ances (see page 8)

4. Clean burner (see Cleaning and Mainte-

nance, page 21) or replace burner orifice

1. Turn heater off when using furniture pol-

ish, wax, cleaners, or similar products

1. Replace 9-volt batteries in receiver and

remote control

TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. Burner orifice clogged

2. Inlet gas pressure is too low
3. Burner orifice diameter is too small
4. Thermopile leads disconnected or im-

properly connected

5. Burners will not come on in remote po-

sition

1. Manifold pressure is too low
2. Burner orifice clogged

1. Burner orifice is clogged or damaged

2. Damaged burner
3. Gas regulator defective

1. Not enough air

2. Gas regulator defective
3. Residues from manufacturing processes

and logs curing

1. Not enough combustion/ventilation air

1. Turning control knob to HI position

when burner is cold

2. Air in gas line

3. Air passageways on heater blocked

4. Dirty or partially clogged burner orifice

1. When heated, vapors from furniture pol-

ish, wax, carpet cleaners, etc. turn into
white powder residue

1. Battery is not installed. Battery power

is low

www.desatech.com

Summary of Contents for Vanguard VI33NR

Page 1: ...st be performed by a qualified installer service agency or the gas supplier WARNING Improperinstallation adjustment alteration service or maintenance can cause injury orpropertydamage Refertothis manu...

Page 2: ...ues 7 To prevent the creation of soot follow the instructions in Cleaning and Main tenance page 21 8 Before using furniture polish wax car pet cleaner or similar products turn heater off If heated the...

Page 3: ...sert 5 Check all items for any shipping dam age If damaged promptly inform dealer where you bought fireplace insert REMOTE CONTROL ACCESSORIES There are four optional remote controls that can be purch...

Page 4: ...ace Adjoining rooms are communicating only iftherearedoorlesspassagewaysorventila tion grills between them PRODUCT FEATURES OPERATION This vent free fireplace insert is clean burn ing Itrequiresnoouts...

Page 5: ...Btu Hr Total ___________________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space c...

Page 6: ...thin 12 of the ceiling and one within 12 of the floor Connecttheseitemsdirectlytotheoutdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces Follow the National Fuel Gas Code NFP...

Page 7: ...all local codes WARNING Never install the fireplace insert in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from...

Page 8: ...holding edges of brass trim together tighten both set screws on the adjusting plate with slotted screwdriver 14 Repeat for other side 15 Line up holes in brass trim with holes on side panels of firep...

Page 9: ...flexible gas line to gas supply See Connecting Fireplace Insert to Gas Supply page 10 6 Plug electrical cord into electrical out let installed in step 2 7 Carefully place fireplace insert into masonr...

Page 10: ...ture and contaminants This keeps them from going into fireplace insert gas controls If sediment trap is not installed or is installed wrong fireplace may not run properly Installation must include an...

Page 11: ...of liquid soap and water to gas joints Bubbles forming show a leak 4 Correct all leaks at once Pressure Testing Fireplace Insert Gas Connections 1 Open equipment shutoff valve see Figure 20 2 Open ma...

Page 12: ...see Figure 23 IMPORTANT Make sure log does not cover any burner ports 2 Install fireplace insert screen by slip ping notches of fireplace insert screen over screws on front of fireplace insert see Fig...

Page 13: ...3 Replace battery cover onto remote con trol unit Figure 29 Installing Battery in Hand Held Remote Control Unit GHRC Series Battery Cover 9 Volt Battery Terminal Wires Remote Control Unit Battery Hou...

Page 14: ...umn 1 2 Make sure equipment shutoff valve is fully open 3 Set switch to OFF position 4 Press in and turn control knob clock wise to the OFF position 5 Wait five 5 minutes to clear out any gas Then sme...

Page 15: ...r 1 Turn control knob clockwise to the OFF position 2a SetselectorswitchintheOFFposition 2b If Using Optional Hand Held Re mote Set remote selector switch in the OFF position to keep from drain ing ba...

Page 16: ...the temperature setting being turned up or down IMPORTANT The hand held re mote control unit must be near the heater Do not keep the hand held remote control unit too close to the heater The thermosta...

Page 17: ...alve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located...

Page 18: ...ion 1 Refer to Air for Combustion and Venti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line che...

Page 19: ...most fireplaces If noise is excessive contact qualified ser vice person 1 Open window and ventilate room Stop using odor causing products while fire place insert is running 2 Locate and correct all l...

Page 20: ...factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If theycan tsupplyoriginalreplacementpart s call DESA International at 1 866 672 6040 forreferralinformation WhencallingDES...

Page 21: ...esoot We recommendthatyoucleantheuniteverythree months during operation and have heater in spected yearly by a qualified service person Wealsorecommendthatyoukeeptheburner tube and pilot assembly clea...

Page 22: ...LACE INSERT DESA INTERNATIONAL For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL VI33NR 17 27 4 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1 5 9 28 14 13 25...

Page 23: ...ner 2 9 M11084 38 Screw 8 x 38 2 10 104236 01CK Painted Base Assy 1 11 M12461 26 Screw 10 x 32 4 12 104238 01CK Firebox Bottom 1 13 103284 03 Wiring Harness 1 14 098265 02 Elbow Male 1 15 103782 01 Va...

Page 24: ...IREPLACE INSERT DESA INTERNATIONAL For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN FIREPLACE INSERT VI33NR 11 14 8 8 14 9 3 14 9 9 2 1 7 10 14 12 5 14 13 15 23 4 6 6 17 16 18 1...

Page 25: ...ebox Hood 1 8 101348 01 Firebox Support 2 9 099230 02 Shoulder Screw 4 10 101872 03 Firebox Top 1 11 101346 01CK Outer Base 1 12 105232 01CK Firebox Wrapper 1 13 101614 02 Cover and Switch Assembly 1...

Page 26: ...W Purchase these fireplace insert accessories fromyourlocaldealer Iftheycannotsupply theseaccessories callDESAInternational s Sales Department at 1 866 672 6040 for information You can also write to...

Page 27: ..._________________________________________ _______________________________________________________________________________________________ ______________________________________________________________...

Page 28: ...relatedtorepairingadefectiveheaterwillbetheresponsibilityoftheowner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AN...

Reviews: