background image

14

105647

UNVENTED NATURAL GAS FIREPLACE INSERT

DESA INTERNATIONAL

For more information, visit www.desatech.com

LIGHTING

INSTRUCTIONS

OPERATING
FIREPLACE INSERT

FOR YOUR SAFETY

READ BEFORE

LIGHTING

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch;

do not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

 WARNING: You must operate

this heater with the fireplace in-
sert screen in place. Make sure
fireplace insert screen is installed
before running fireplace insert.

NOTICE: During initial operation
of new fireplace insert, burning
logs will give off a paper-burning
smell. Open damper or window
to vent smell. This will only last a
few hours.

1.

STOP! Read the safety information,
column 1.

2.

Make sure equipment shutoff valve
is fully open.

3.

Set switch to OFF position.

4.

Press in and turn control knob clock-
wise 

  to the OFF position.

5.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation. If you don’t smell gas, go
to the next step.

6.

Press in and turn control knob coun-
terclockwise  

  to the PILOT

position. Press in control knob for
five (5) seconds (see Figure 31).

 WARNING: Burners will come

on automatically within one
minute when the remote selector
switch is in the ON position after
the pilot is lit.

 CAUTION: Do not try to adjust

heating levels by using the equip-
ment shutoff valve.

Note: 

You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or more. This will al-
low air to bleed from the gas system.

7.

With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.

Note:

 If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure
 on page 15.

8.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out

when released, contact a qualified
service person or gas supplier for
repairs.

Note:

 If pilot goes out, repeat steps

4 through 8.

9.

Slightly push in and turn control
knob counterclockwise  

 to

the ON position.

10. Wait one minute and switch selector

switch to the ON position to light
burners.

11. Set flame adjustment knob to any

level between HI and LO.

O

F

F

PIL

OT

O

N

L O

I H

AUTO
OFF
ON

Figure 31 - Control Knob and Ignitor Button Location (Shown as Supplied,
No Control Options)

Control Knob

Ignitor Button

 Selector Switch

Flame Adjustment
Knob

Summary of Contents for Vanguard VI33NR

Page 1: ...st be performed by a qualified installer service agency or the gas supplier WARNING Improperinstallation adjustment alteration service or maintenance can cause injury orpropertydamage Refertothis manu...

Page 2: ...ues 7 To prevent the creation of soot follow the instructions in Cleaning and Main tenance page 21 8 Before using furniture polish wax car pet cleaner or similar products turn heater off If heated the...

Page 3: ...sert 5 Check all items for any shipping dam age If damaged promptly inform dealer where you bought fireplace insert REMOTE CONTROL ACCESSORIES There are four optional remote controls that can be purch...

Page 4: ...ace Adjoining rooms are communicating only iftherearedoorlesspassagewaysorventila tion grills between them PRODUCT FEATURES OPERATION This vent free fireplace insert is clean burn ing Itrequiresnoouts...

Page 5: ...Btu Hr Total ___________________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space c...

Page 6: ...thin 12 of the ceiling and one within 12 of the floor Connecttheseitemsdirectlytotheoutdoors orspacesopentotheoutdoors Thesespaces include attics and crawl spaces Follow the National Fuel Gas Code NFP...

Page 7: ...all local codes WARNING Never install the fireplace insert in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from...

Page 8: ...holding edges of brass trim together tighten both set screws on the adjusting plate with slotted screwdriver 14 Repeat for other side 15 Line up holes in brass trim with holes on side panels of firep...

Page 9: ...flexible gas line to gas supply See Connecting Fireplace Insert to Gas Supply page 10 6 Plug electrical cord into electrical out let installed in step 2 7 Carefully place fireplace insert into masonr...

Page 10: ...ture and contaminants This keeps them from going into fireplace insert gas controls If sediment trap is not installed or is installed wrong fireplace may not run properly Installation must include an...

Page 11: ...of liquid soap and water to gas joints Bubbles forming show a leak 4 Correct all leaks at once Pressure Testing Fireplace Insert Gas Connections 1 Open equipment shutoff valve see Figure 20 2 Open ma...

Page 12: ...see Figure 23 IMPORTANT Make sure log does not cover any burner ports 2 Install fireplace insert screen by slip ping notches of fireplace insert screen over screws on front of fireplace insert see Fig...

Page 13: ...3 Replace battery cover onto remote con trol unit Figure 29 Installing Battery in Hand Held Remote Control Unit GHRC Series Battery Cover 9 Volt Battery Terminal Wires Remote Control Unit Battery Hou...

Page 14: ...umn 1 2 Make sure equipment shutoff valve is fully open 3 Set switch to OFF position 4 Press in and turn control knob clock wise to the OFF position 5 Wait five 5 minutes to clear out any gas Then sme...

Page 15: ...r 1 Turn control knob clockwise to the OFF position 2a SetselectorswitchintheOFFposition 2b If Using Optional Hand Held Re mote Set remote selector switch in the OFF position to keep from drain ing ba...

Page 16: ...the temperature setting being turned up or down IMPORTANT The hand held re mote control unit must be near the heater Do not keep the hand held remote control unit too close to the heater The thermosta...

Page 17: ...alve damaged REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located...

Page 18: ...ion 1 Refer to Air for Combustion and Venti lation requirements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line che...

Page 19: ...most fireplaces If noise is excessive contact qualified ser vice person 1 Open window and ventilate room Stop using odor causing products while fire place insert is running 2 Locate and correct all l...

Page 20: ...factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this product If theycan tsupplyoriginalreplacementpart s call DESA International at 1 866 672 6040 forreferralinformation WhencallingDES...

Page 21: ...esoot We recommendthatyoucleantheuniteverythree months during operation and have heater in spected yearly by a qualified service person Wealsorecommendthatyoukeeptheburner tube and pilot assembly clea...

Page 22: ...LACE INSERT DESA INTERNATIONAL For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL VI33NR 17 27 4 O F F P I L O T O N H I L O 8 12 26 7 6 4 3 2 1 5 9 28 14 13 25...

Page 23: ...ner 2 9 M11084 38 Screw 8 x 38 2 10 104236 01CK Painted Base Assy 1 11 M12461 26 Screw 10 x 32 4 12 104238 01CK Firebox Bottom 1 13 103284 03 Wiring Harness 1 14 098265 02 Elbow Male 1 15 103782 01 Va...

Page 24: ...IREPLACE INSERT DESA INTERNATIONAL For more information visit www desatech com ILLUSTRATED PARTS BREAKDOWN FIREPLACE INSERT VI33NR 11 14 8 8 14 9 3 14 9 9 2 1 7 10 14 12 5 14 13 15 23 4 6 6 17 16 18 1...

Page 25: ...ebox Hood 1 8 101348 01 Firebox Support 2 9 099230 02 Shoulder Screw 4 10 101872 03 Firebox Top 1 11 101346 01CK Outer Base 1 12 105232 01CK Firebox Wrapper 1 13 101614 02 Cover and Switch Assembly 1...

Page 26: ...W Purchase these fireplace insert accessories fromyourlocaldealer Iftheycannotsupply theseaccessories callDESAInternational s Sales Department at 1 866 672 6040 for information You can also write to...

Page 27: ..._________________________________________ _______________________________________________________________________________________________ ______________________________________________________________...

Page 28: ...relatedtorepairingadefectiveheaterwillbetheresponsibilityoftheowner TO THE FULL EXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AN...

Reviews: