background image

NOT A UPC

110749 01

110749-01
Rev. E
09/08

DESA Heating, LLC
2701 Industrial Drive

Bowling Green, KY 42101
www.desatech.com

1-866-672-6040

Warranty

KeeP tHis Warranty

desa Heating, llC liMited Warranties

New products

standard Warranty:

 DESA Heating, LLC warrants this new product and any parts thereof to be free from 

defects in material and workmanship for a period of four (4) years from the date of first purchase from an 
authorized dealer provided the product has been installed, maintained and operated in accordance with 
DESA Heating, LLC’s warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from 
the date of first purchase.

Factory Reconditioned products

limited Warranty:

 DESA Heating, LLC warrants factory reconditioned products and any parts thereof 

to be free from defects in material and workmanship for 30 days from the date of first purchase from an 
authorized dealer provided the product has been installed, maintained and operated in accordance with 
DESA Heating, LLC’s warnings and instructions.

terms common to All Warranties

The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under 
this warranty the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, 
and only when installed by a qualified installer in accordance with all local codes and instructions furnished 
with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and 
an allowance for labor when provided by a DESA Heating, LLC Authorized Service Center or a provider 

approved by DESA Heating, LLC. Warranty parts must be obtained through authorized dealers of this prod-

uct and/or DESA Heating, LLC who will provide original factory replacement parts. Failure to use original 
factory replacement parts voids this warranty.
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty 
repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the 
responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, 

improper installation, lack of proper maintenance, tampering, or alteration(s).

This is DESA Heating, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty 
excludes any and all other warranties, express or implied, written or verbal and limits the duration of any 
and all implied warranties, including warranties of merchantability and fitness for a particular purpose to four 
(4) years on new products and 30 days on factory reconditioned products from the date of first purchase. 
DESA Heating, LLC makes no other warranties regarding this product.

DESA Heating, LLC’s liability is limited to the purchase price of the product, and DESA Heating, LLC shall 

not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or 
consequential damages.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of 
incidental or consequential damages, so the above limitation or exclusion may not apply to you. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 
For information about this warranty contact:

Model (

located on product or identification tag

) _____________________________

Serial No. (

located on product or identification tag

) __________________________

Date Purchased  __________________________

Keep receipt for warranty verification.

Summary of Contents for V50S

Page 1: ...s fired unvented decorative room heater Not to exceed 40 000 Btu Hr Do not build a wood fire Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fi...

Page 2: ...operty damage Refer to this manual for correct in stallation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNIN...

Page 3: ...sed or stored under dusty conditions 6 Do not use this firebox to cook food or burn paper or other objects 7 Turn unit off and let cool before servicing Only a qualified service person should service...

Page 4: ...ner Your firebox features a concrete refractory brick liner As with all concrete liners this liner may develop slight cracks when exposed to heat These cracks will not affect the perfor mance of the f...

Page 5: ...rectly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space Adjoining rooms are communicating only if there are...

Page 6: ...tion air from the outdoors and vents to the outdoors Example Gas water heater __________ Btu Hr Vent free fireplace _________ Btu Hr Total _________ Btu Hr 4 Compare the maximum Btu Hr the space can s...

Page 7: ...ills or ducts You must provide two perma nent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the outdoors These spa...

Page 8: ...flooring firebox should be installed on a metal or wood panel extending the full width and depth of enclosure D Clearances from the bottom of firebox to the floor is 0 Installation Figure 4 Minimum C...

Page 9: ...emove mantel Built In Firebox Installation Built in installation of this firebox involves installing firebox into a framed in enclosure Installation Continued This makes front of firebox flush with wa...

Page 10: ...ke louvered slots Installation Continued Figure 7 Attaching Firebox to Wall Studs Nailing Flanges Nails or Wood Screws Figure 8 Installing Cabinet Mantel Mantel May Vary From Illustration Cabinet Mant...

Page 11: ...s Line and Equipment Shutoff Valve Model May Vary From Illustration Knockout Locations Knock Out One Hole Gas Line Hole Locate recessed knockout in one of the fire brick sidewall liners see Figures 10...

Page 12: ...FIREPLACE HOOD AND SCREEN 1 Attach hood to firebox using screws pro vided see Figure 12 2 Insert each rod through all rings located at top of screen 3 Insert first rod into rear hole in left side of...

Page 13: ...alling DESA Heating LLC have ready model and serial numbers of your heater the replacement part number You may have further questions about installa tion operation or troubleshooting If so con tact DE...

Page 14: ...www desatech com 110749 01E 14 Parts Models V50H V50S and VFB50NC 1 1 1 2 3 4 5 7 28 9 10 6 11 12 13 29 31 8 16 17 18 19 33 34 19 26 25 25 23 38 32 36 37 35 20 21 22 14 24 30 6...

Page 15: ...111428 02 Bottom Rear Refractory Red 1 111512 02 Bottom Rear Refractory H Bone 1 22 111423 01 Right Refractory 1 111423 02 Right Refractory Red 1 111507 02 Right Refractory H Bone 1 23 111424 01 Left...

Page 16: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Reviews: