background image

www.desatech.com

116646-01H

4

SaFETy 

Continued

8.  Have venting system inspected annually by 

a qualified service person. If needed, have 
venting system cleaned or repaired. See 

Cleaning and Maintenance

, page 30. 

9.  Do not use this fireplace to cook food or 

burn paper or other objects.

10. This appliance, when installed, must be 

electrically grounded in accordance with 
local  codes  or,  in  the  absence  of  local 

Figure 1 - Direct-Vent Fireplace with Millivolt Ignition

Glass Door Assembly

ON/OFF/REMOTE Switch 
(Optional Installation)

Log Set

Lava Rock

Glowing 
Embers

Upper Louver Panel

Lower Louver Panel

Flue Collar

Nailing Flange

Grate Assembly

Piezo Ignitor

Control Valve

Blower Switch (Optional Installation)

lOCal CODES

codes, with the 

National Electrical Code, 

ANSI/NFPA 70

.

11. Do not use fireplace if any part has been 

under water. Immediately call a qualified 
service person to arrange for replacement 
of the unit.

12. Do not operate fireplace if log is broken. 
13. Provide adequate clearances around air 

openings.

pRODUCT IDENTIFICaTION

Install and use fireplace with care. Follow all 
local  codes. In the absence  to local  codes, 
use the current 

National Fuel Gas Code ANSI 

Z223.1/NFPA 54*

.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

pRODUCT FEaTURES

These are a few facts that can help you under

-

stand and enjoy your direct-vent fireplace:
•  The venting system may be routed to the 

outside of your home in several ways. It may 
vent through the roof (vertical) or it may vent 
to an outside/exterior wall (horizontal). The 
vent  pipe  installation  is  very  important  to 
allow for proper operation. You must follow 
the  venting  instructions  very  carefully  for 
either vertical or horizontal applications.

•  This fireplace may be installed in any room 

of your house provided all local codes and 
these installation instructions are followed.

•  This fireplace does not require electricity 

to operate.

•  Only  the  blower  requires  electricity  if 

installed. If you plan to install the blower 
at a later date, outlet must be wired at the 
bottom of the fireplace when framing.

•  A piezo ignitor and ceramic electrode create 

sparks to ignite the pilot light. It does not 
require any matches, batteries or any other 
sources of ignition to light the pilot.

•  Each time you turn on your fireplace, you 

may notice some amount of condensation 
on  the  inside  of  the  fireplace  glass. This 
is  normal  and  will  disappear  after  10-20 
minutes of operation.

•  Your  direct-vent  gas  fireplace  system 

(fireplace and venting) is a balanced and 

Summary of Contents for "TUDOR" CGDV32NR

Page 1: ...ore or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switc...

Page 2: ...oduc tive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble op erate or service this fireplace Improper use of this fireplace cancauseseriousinjuryordeath from bu...

Page 3: ...Keep the appliance area clear and free from combustible ma terials gasoline and other flam mable vapors and liquids Do not place clothing or other flammable material on or near fireplace Never place a...

Page 4: ...rican National Standards Institute Inc 1430 Broadway New York NY 10018 National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 Product Features These are a few facts that can help y...

Page 5: ...irectly against wall or framing material See framing details on page 6 If you plan on installing a television or enter tainment center recessed above your fire place it is recommended that you maintai...

Page 6: ...All minimum clearances must be met For available accessories for this fireplace see Accessories on page 37 If you are using a separate combustible mantel piece refer to Figure 6 for proper installati...

Page 7: ...000 and 50 000 12 30 cm in Canada if between 10 000 and 100 000 12 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada...

Page 8: ...are tested and approved for use with DESA direct vent pipe components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue...

Page 9: ...ipes Push pipe sections together and twist one section clockwise approximately one quarter turn until sections are fully locked see Figure 8 Note Horizontal runs of vent must be supported every three...

Page 10: ...ior fascia material 7 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before connecting horizontal run to vent cap see Figure 12 Carefully move fireplace with vent as...

Page 11: ...or every 12 of run toward termination is required NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cau...

Page 12: ...installation where pipe vents horizontally through wall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION...

Page 13: ...n for Venting Using Two 90 Elbows Venting with Two 90 Elbows Horizontal H1 Vertical V Horizontal H1 Horizontal H2 5 min 2 max 6 max 6 min 4 max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20 max 8 ma...

Page 14: ...clearance space If area above ceiling is a living space install firestop below framed hole Firestop should be installed with no less than 3 nails per side see Figure 20 2 Assemble desired lengths of p...

Page 15: ...24 show four different configurations for vertical termination Venting Installation Continued Figure 21 Vertical Venting Configuration Using Two 90 Elbows with Two Horizontal Runs Vertical Round High...

Page 16: ...e Figure 25 and a round horizontal termination be used Figure 25 Recommended 12 Extension for High Altitude Installation 45 Starter Elbow 12 Extension Parts list for venting kits and components DESA H...

Page 17: ...h HTS 58 RF 58 Flat Roof Flashing PF58 927 Flex Pipe Section 9 to 24 PF58 1236 Flex Pipe Section 12 to 36 PF58 1854 Flex Pipe Section 18 to 54 VKF58 927 Flex Kit Includes Flex Pipe Wall Section 9 to 2...

Page 18: ...Wiring Diagram Decal 12 in Front of Blower Speed Control Control Shaft Locknut Control Knob Switch Bracket Blower Plug In Duplex Outlet Located underneath firebox floor against lower right outside wal...

Page 19: ...Thermal Switch Bracket Power Cord Air Flow Direction Magnetic Strips Figure 30 Blower Wiring Diagram for Thermostat Controlled Models Blower Wiring Diagram CAUTION Label all wires prior to disconnecti...

Page 20: ...ming gas pressure to between 11 and 14 of water If you do not reduce incoming gas pressure Figure 31 External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulato...

Page 21: ...Bubblesformingshow a leak Correct all leaks at once PRessure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnectfireplaceanditsindividualequip ment shutoff valve...

Page 22: ...to gas valve see Figure 35 or Figure 36 Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operation page 26 Check all o...

Page 23: ...emote control unit see Figure 40 2 Attach terminal wires to battery Place battery into battery housing 3 Replace battery cover onto remote control unit Figure 40 Installing Battery in Hand Held Remote...

Page 24: ...inued Figure 42 Removing Replacing Glass Door Lock Unlock Glass Frame Assembly Screw Hinge Latch Installing Optional Brick liner Model BL32D WARNING If fireplace has been running turn off and un plug...

Page 25: ...as instructed Do not modify logs Only use logs supplied with fireplace Open louvers remove screen unlock door latches and open glass door See steps 1 and 2 of Removing Glass Door page 24 Install logs...

Page 26: ...UR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance is equi...

Page 27: ...se lower louver panel O F F PILOT LO IH O N Piezo Ignitor Gas Control Knob Variable Control Knob Figure 51 Control Valve Operation Continued TO TURN OFF GAS TO APPLIANCE 1 Open lower louver panel 2 Se...

Page 28: ...rn on the hand held remote control 2 Press AUTO button to select this mode 3 Set the desired room temperature by pressing the TEMP or buttons 4 Press the POWER and LOCK buttons together to turn off th...

Page 29: ...nd turn gas control knob back to PILOT The pilot will remain lit IMPORTANT To turn pilot off turn gas control knob on heater to the OFF position Operating optional blower accessory Locate blower contr...

Page 30: ...Fireplace may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc GLASS DOOR WARNING Handle glass door panel with care Do not strike slam or otherwise abuse...

Page 31: ...t bristled brush to remove excess dust dirt or lint logs If you remove logs for cleaning refer to Installing Logs Lava Rock and Glowing Embers page 25 to properly replace logs Use a vacuum cleaner to...

Page 32: ...utoff valve closed 2 Gas control knob not in PILOT position 3 Gas control knob not pressed in while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP models only 6...

Page 33: ...pressure is too low 2 Burner porting or orifice clogged 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective 1 Residues from manufac turing processes and logs curing REME...

Page 34: ...talla tion REMEDY 1 Turn gas control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local propane LP or natural gas company 3...

Page 35: ...Installing Logs Lava Rock and Glowing Embers page 25 2 Clean out air holes at burn er inlets Periodically repeat as needed 3 Remove blockage or re place burner 4 Have the vent system in spected inclu...

Page 36: ...t propane LP gas supply might be low pro pane LP units only You may feel your gas pressure is too low If so contact your local gas supplier Technical Service You may have further questions about insta...

Page 37: ...conveniently A wall mount docking station is included Wall mounted thermostat control kit gwmt1 Allowseasywallaccessfor thermostatic opera tion of your fireplace Wall mounted on off switch gwmS2 Allow...

Page 38: ...46 01H 38 6 7 21 18 19 10 13 2 12 20 8 22 2 22 6 22 4 22 5 22 3 22 1 1 14 9 11 17 15 4 5 16 3 Parts Models V T32N A V T32NB A V T32NR A V T32NRB A V T32P A V T32PB A V T32PR A V T32PRB A CGDV32NR CGDV...

Page 39: ...40 41 1 10 108890 01 108890 01 Burner Base Gasket 1 11 109082 03 109082 03 Heat Shield 1 12 108897 01 108897 01 Rear Refractory Brick Panel B Models Only 1 13 108901 01 108901 01 Right Refractory Bri...

Page 40: ...h com 116646 01H 40 3 2 1 13 14 18 15 16 4 5 7 8 6 9 12 10 11 17 19 PARTS Burner assembly Models V T32N A V T32NB A V T32NR A V T32NRB A V T32P A V T32PB A V T32PR A V T32PRB A CGDV32NR CGDV32PR and C...

Page 41: ...104506 02 Orifice Propane LP 55 1 12 104509 02 Aluminum Tubing Assy 1 13 26808 Valve Bracket 1 14 26827 Switch Bracket 1 15 108886 01 Base Grate Assembly 1 16 108891 01 Burner 1 17 108084 02 Pilot As...

Page 42: ...____ _____________________________________________________ _____________________________________________________ _____________________________________________________ _________________________________...

Page 43: ...____ _____________________________________________________ _____________________________________________________ _____________________________________________________ _________________________________...

Page 44: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Reviews: