Desa SL-5326 User Manual Download Page 3

3

598-1274-00

TEST AND ADJUSTMENT

 

Turn on the circuit breaker and light switch.

Motion

Motion

The detector is most sensitive to motion across its fi eld 
of view.

  Loosen the clamp screw in the 

sensor ball joint and gently 
rotate the sensor.

  Walk through the coverage 

area noting where you are 
when the lights turn on (also, 
the LED will fl ash several times 
when motion is detected). Move 
the sensor head up, down, or 
sideways to change the cover-
age area. 

Keep the sensor at 

least 1" (2.5 cm) away from 
the lamps.

  Adjust the RANGE as needed. 

RANGE set too high may 
increase false triggering.

 

Secure the sensor head by 
tightening the clamp screw.

 

Do not overtighten the screw.

  Set the amount of TIME you want the lights to stay 

on after motion is detected (1, 5, or 20 minutes).

  Set the 2-L

EVEL

 Lighting switch to the  amount of 

time after dusk you want the lights on at low level 
(Off, 3, 6 Hrs., Dusk-to-Dawn).

SPECIFICATIONS

Range ............................. Up to 70 ft. (21 m); 100 ft.

(30.5 m) with Range Boost. 

 

[varies with surrounding tem-
perature]

Sensing Angle ................ Up to 240°
Electrical Load ................ Up  to  300 Watt Maximum 

Incandescent [Up to 150 
Watt maximum each lamp 
holder.]

Power Requirements ...... 120 VAC, 60 Hz
Operating Modes ............ TEST, AUTO and MANUAL 

MODE

Time Delay ..................... 1, 5, 20 minutes
2-Level Lighting Timer .... 3, 6 hours, Dusk-to-Dawn

DESA Specialty Products reserves the right to discon-
tinue products and to change specifi cations at any 
time without incurring any obligation to incorporate 
new features in products previously sold.

NOTE:

  Sensor has a 1 

1

/

2

 minute warm up period 

before it will detect motion. When fi rst turned 
on, wait 1 

1

/

2

 minutes.

Bottom of Sensor

 

Avoid aiming the control at:

•  Objects that change temperature rapidly, such as 

heating vents and air conditioners.

 These heat 

sources could cause false triggering.

•  Areas where 

pets or traffi c

 may trigger the control.

•  

Nearby large, light-colored objects

 refl ecting light 

may trigger the shut-off feature. Do not point other 
lights at the sensor.

70 ft.

(21 m)

8 ft. 

(2.4 m)

240°

Clamp 
Screw

Ball 
Joint

Aim Sensor 

Down for Short 

Coverage

Aim Sensor 

Higher for Long 

Coverage

 

Least Sensitive 

 Most Sensitive

Sensor

  Warning - Risk of fi re. Do not aim the lamps 

at a combustible surface within 3 ft. (1 m).

 Maximum 

Range  Maximum

  

Coverage 

Angle

B

O

O

S

T

MAX

MIN

RANGE

ON - TIME

DUAL BRITE

TEST 1  5  2 0

MINUTES

OFF  3  6   DUSK TO

HOUR   DAWN

100 ft.

(30.5 m)
Boosted

  Turn the RANGE control to the mid position, 2-Level 

Lighting to OFF and the ON-TIME control to the 
TEST position.

Summary of Contents for SL-5326

Page 1: ... 5 or 20 minute position Manual mode only works at night because daylight returns the sensor to AUTO Flip the light switch off for one second thenbackontotogglebetweenAUTO and MANUAL MODE Manual mode works only with the ON TIME switch in the 1 5 or 20 position Move ON TIME Switch to 1 5 or 20 minutes Mode Switching Summary Flip light switch off for one second then back on MANUAL MODE AUTO TEST If ...

Page 2: ...the clamp screw when done Then rotate the sensor head clockwise 180 so the controls face down Controls Wall Mount Eave Mount For under eave installation the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock Mounting Strap Mounting Bolt Controls Controls Clamp Screw Rubber Plug MOUNT THE LIGHT CONTROL Align the Light Control co...

Page 3: ...equirements 120 VAC 60 Hz Operating Modes TEST AUTO and MANUAL MODE Time Delay 1 5 20 minutes 2 Level Lighting Timer 3 6 hours Dusk to Dawn DESA Specialty Products reserves the right to discon tinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold NOTE Sensor has a 1 1 2 minute warm up period before it will d...

Page 4: ...CIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR NOT FORESEEABLE Some states or provinces do not allow the exclusion or limitation o...

Page 5: ...bertora Portalámparas Características Prende la luz cuando detecta movimiento Apaga la luz automáticamente Temporizador del alumbrado de 2 niveles La fotocélula mantiene la luz apagada durante el día LED indica que se ha detectado movimiento durante el día o la noche Si se confunde mientras cambia de fases apague la electricidad por un minuto y préndala de nuevo Después del tiempo de calibración e...

Page 6: ...puede pasar por el agujero en el centro de la placa cubertora El extremo pequeño va luego dentro de las ranuras de la lámina de montaje Pase todos los cables del aparato por los agujeros grandes del empaque como se muestra Conecte los cables de la caja de empalme con los cablesdelaparatodeluz comosemuestra Tuérazalos juntos y asegúrelos con un conector de cables INSTALE EL CONTROL DE LUZ Pongaelpe...

Page 7: ...5 20 minutos Temporizador del alumbrado de 2 niveles Apagado 3 6 horas del atardecer al amanecer DESA Specialty Products se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligación de tener que incorporar nuevas características en los productos vendidos con anterioridad NOTA El detector tiene un período de cerca de 1 1 2 minu...

Page 8: ...Compruébelo cuando comience la obscuridad 5 Alambrado incorrecto si ésta es una nueva instalación 6 Noestáapuntandocorrectamen te Apunte de nuevo el detector para proteger el área deseada 1 ElControldeLuzpuedeestarins talado en un lugar relativamente oscuro 2 El Control de Luz está en fase de Prueba Fijeelinterruptordelcon trol a la posición de TIEMPO 1 El Control de Luz puede estar detectando ani...

Reviews: