background image

2

598-1274-00

INSTALLATION

For easy installation, select an existing light with a wall 
switch for replacement.

W

IRE

 

THE

 L

IGHT

 C

ONTROL

 WARNING: Turn power off at circuit breaker.

❒ 

Remove the existing light fi xture.

  Install the mounting strap as shown using two screws 

that fi t your junction box.

  The plastic hanger can be used to hold the fi xture 

while wiring. The small end of the plastic hanger 
can be threaded through the hole in the center of 
the cover plate. The small end then goes into one 
of the slots on the mounting strap.

❒ 

Route the Light Control’s wires through the large 
gasket holes.

 

 Twist the

 

junction box wires and fi xture wires together 

as shown. Secure with wire connectors.

White

 to 

White

Black

 to 

Black

Junction box ground wire to 
green ground screw on fi xture.

Gasket

For eave mount only:

  Swing the sensor head towards the clamp screw 

joint. 

If the sensor pops out of the ball joint, loosen the 
clamp screw and push the sensor back into the ball 
joint. Tighten the clamp screw when done.

  Then rotate the sensor head clockwise 180° so the 

controls face down.

Controls

Wall Mount

Eave Mount

For under eave installation, the sensor head must 
be rotated

 as shown in the next two steps for proper 

operation and to avoid the risk of electrical shock.

Mounting 

Strap

Mounting 

Bolt

Controls

Controls

Clamp Screw

Rubber 

Plug

M

OUNT

 

THE

 L

IGHT

 C

ONTROL

  Align the Light Control cover plate and cover plate 

gasket. Secure with the mounting bolt.

 

For model SL-5318 only,

 align the three slots in 

the decorative shell with the lamp holder pins. Push 
the shell in and then twist clockwise to lock. Repeat 
for other shell.

Lock Nut

To avoid water damage and electrical shock, 
keep lamp holders 30° below horizontal.

❒ 

Adjust the lamp holders by loosening the lock nuts 
but do not rotate the lamp holders more than 180° 
from the factory setting. When screwing in the 
fl oodlamps, do not overtighten.

Keep lamps at least 
1" (2.5 cm) from the 
sensor. Do not allow 
the lamps to block 
the lens.

Lens

  Push the Rubber Plug fi rmly into place.

  If a wet location junction box was not used, caulk 

the wall plate mounting surface with silicone 
weather sealant.

Shell Slot

Summary of Contents for SL-5326

Page 1: ... 5 or 20 minute position Manual mode only works at night because daylight returns the sensor to AUTO Flip the light switch off for one second thenbackontotogglebetweenAUTO and MANUAL MODE Manual mode works only with the ON TIME switch in the 1 5 or 20 position Move ON TIME Switch to 1 5 or 20 minutes Mode Switching Summary Flip light switch off for one second then back on MANUAL MODE AUTO TEST If ...

Page 2: ...the clamp screw when done Then rotate the sensor head clockwise 180 so the controls face down Controls Wall Mount Eave Mount For under eave installation the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock Mounting Strap Mounting Bolt Controls Controls Clamp Screw Rubber Plug MOUNT THE LIGHT CONTROL Align the Light Control co...

Page 3: ...equirements 120 VAC 60 Hz Operating Modes TEST AUTO and MANUAL MODE Time Delay 1 5 20 minutes 2 Level Lighting Timer 3 6 hours Dusk to Dawn DESA Specialty Products reserves the right to discon tinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold NOTE Sensor has a 1 1 2 minute warm up period before it will d...

Page 4: ...CIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR NOT FORESEEABLE Some states or provinces do not allow the exclusion or limitation o...

Page 5: ...bertora Portalámparas Características Prende la luz cuando detecta movimiento Apaga la luz automáticamente Temporizador del alumbrado de 2 niveles La fotocélula mantiene la luz apagada durante el día LED indica que se ha detectado movimiento durante el día o la noche Si se confunde mientras cambia de fases apague la electricidad por un minuto y préndala de nuevo Después del tiempo de calibración e...

Page 6: ...puede pasar por el agujero en el centro de la placa cubertora El extremo pequeño va luego dentro de las ranuras de la lámina de montaje Pase todos los cables del aparato por los agujeros grandes del empaque como se muestra Conecte los cables de la caja de empalme con los cablesdelaparatodeluz comosemuestra Tuérazalos juntos y asegúrelos con un conector de cables INSTALE EL CONTROL DE LUZ Pongaelpe...

Page 7: ...5 20 minutos Temporizador del alumbrado de 2 niveles Apagado 3 6 horas del atardecer al amanecer DESA Specialty Products se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligación de tener que incorporar nuevas características en los productos vendidos con anterioridad NOTA El detector tiene un período de cerca de 1 1 2 minu...

Page 8: ...Compruébelo cuando comience la obscuridad 5 Alambrado incorrecto si ésta es una nueva instalación 6 Noestáapuntandocorrectamen te Apunte de nuevo el detector para proteger el área deseada 1 ElControldeLuzpuedeestarins talado en un lugar relativamente oscuro 2 El Control de Luz está en fase de Prueba Fijeelinterruptordelcon trol a la posición de TIEMPO 1 El Control de Luz puede estar detectando ani...