background image

10

099156

ACCESSORIES

Purchase these accessories
and parts from your local
dealer or service center. If
your dealer or service center
can not supply an accessory or
part, contact your nearest
Parts Central (listed in the
separate Authorized Service
Center booklet) or call DESA
International’s Parts Depart-
ment at 1-800-972-7879. You
can also write to the address
listed on the back page of this
manual.

Part Number

Description

LPA1020

10' Rubber Hose with Brass Fitting
U.L. listed.

LPA1030

15' Rubber Hose with Brass Fitting
U.L. listed.

LPA2010

Propane Gas Regulator
U.L. listed.

LPA3000

Hose/Regulator Assembly
U.L. listed.

LPA4000

Piezo Ignitor Kit
For matchless ignition.

LPA4010

Debris Shield
Protects valve controls from paint, plaster, and
other drying liquids.

LPA4020

Fuel Gas Connector
Connects regulator to all standard propane tanks.
U.L. and A.G.A. listed.

LPA2060

Adjusting Regulator and Gauge Assembly
Allows for reduced input operation where less
heat is needed.

You can obtain an Illustrated Parts List free of charge. Send your request along
with a self-addressed, stamped envelope to the address listed on the back page of
this manual. Be sure to include the model number of the heater.

SERVICE

PUBLICATION

Parts Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement
part(s), either contact your nearest Parts Central or call DESA International’s
Technical Service Department at 1-800-323-5190.

When calling DESA International, have ready

• your name

• how heater was malfunctioning

• your address

• purchase date

• model number of your heater

In most cases, we will ask you to return the defective part to the factory.

Parts Not Under Warranty

Contact authorized dealers of this product. If they can’t supply original replacement
part(s), either contact your nearest Parts Central or call DESA International’s Parts
Department at 1-800-972-7879.

When calling DESA International, have ready

• model number of your heater
• the replacement part number

REPLACEMENT

PARTS

!

WARNING

Use only original replacement parts. This heater must use design-
specific parts. Do not substitute or use generic parts. Improper
replacement parts could cause serious or fatal injuries. This will
also protect your warranty coverage for parts replaced under
warranty.

Summary of Contents for RCP275

Page 1: ...COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PRO VIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION AND OR CARBON MONOXIDE POISONING ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUC TIONS MANUAL LABEL...

Page 2: ...WARNING NOT FOR HOME OR RECREATIONAL VEHICLE USE The heater is designed for use as a construction heater The primary purpose of construction heaters is to provide temporary heating of buildings under construc tion alteration or repair and to provide temporary emergency heat Properly used the heater provides safe economical heating Products of combustion are vented into the area being heated We can...

Page 3: ...Keep heater away from strong drafts water spray rain or dripping water Never attach duct work to heater Neverblockairinlet bottomofshell orairoutlet aroundtopofshell ofheater Keep children and animals away from heater Locate heater on stable and level surface if heater is hot or operating Minimum heater clearances from combustibles Sides 4 feet Top 6 feet 2 inches Install and use heater with care ...

Page 4: ...KING Figure 1 Product Identification Shell Top Thermocouple Pilot Automatic Control Valve Inlet Connector Base Hose Regulator Assembly Note Debris Shield Not Shown THEORY OF OPERATION The Fuel System The hose regulator assembly attaches to the propane gas supply This provides fuel to the heater The Ignition System The piezo ignitor lights the pilot fuel supply The pilot fuel supply is lit manually...

Page 5: ...e needed in colder weather Your local propane gas dealer will help you select the proper supply system Average Temperature F At Tank Location 60 40 32 20 10 0 Number Of Tanks 2 2 3 3 3 3 SPECIFICATIONS Rating BTU Hr Fuel Fuel Consumption Gallons Hour Pounds Hour Supply Pressure To Regulator Maximum Minimum for input adjustment Regulator Outlet Pressure Weight Pounds Shipping Weight Pounds Size L x...

Page 6: ...nting down Pointing vent down protects regulator from weather damage Supply Valve POL Fitting Hose Regulator Vent pointing down 3 Connect hose to the inlet connector Tighten firmly using 9 16 wrench IMPORTANT Use extra hose or piping if needed Install extra hose or piping between hose regulator assembly and propane tank You must use the regulator supplied with heater even if propane tank has one H...

Page 7: ... heater To Start Heater 1 Follow all installation ventilation and safety information 2 Locate heater on stable and level surface Make sure strong drafts do not blow on heater WARNING Fully close main burner valve before lighting pilot If not severe burns can occur Do this by turning valve handle towards the OFF position until it stops 3 Open propane supply valve on propane tank s slowly Note If no...

Page 8: ...ers over three high if more than one heater is being stored Secure heaters with rope or strap after stacking 1 Store propane tank s in safe manner Refer to Chapter 5 of Standard for Storage and Handling of Liquified Petroleum Gases ANSI NFPA 58 Follow all local codes Always store propane tanks outdoors 2 Place plastic cover caps over brass fittings on inlet connector and hose regulator assembly 3 ...

Page 9: ...al minutes to purge air with automatic control valve button depressed 4 Replace pilot orifice 5 Adjust ignitor electrode gap to 120 Check wire lead for damage Replace piezo ignitor and or ignitor electrode as necessary 1 Relight hold automatic control valve button in 45 seconds 2 Check propane tank s for proper gas supply 3 Tighten connection or replace thermocouple 4 Replace automatic control val...

Page 10: ...uest along with a self addressed stamped envelope to the address listed on the back page of this manual Be sure to include the model number of the heater SERVICE PUBLICATION Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s either contact your nearest Parts Central or call DESA International s Technical Service Department at 1 800 323 ...

Page 11: ...11 099156 NOTES ...

Page 12: ...NCLUDING WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR POSE DESA International assumes no responsibility for indirect incidental or consequential damages Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations or exclusions may not apply to you This Limited Warranty gives you specific legal rights and you may also have other right...

Reviews: