background image

For information, write: DESA International, P.O. Box 90004

Bowling Green, Kentucky 42102-9004 ATTN: Customer Service Department

When writing, always include model number and serial number.

099156-01
Rev. D
12/92

DESA International warrants this product and any parts thereof, to be free from defects in materials and workmanship for
six (6) months from the date of first purchase when operated and maintained in accordance with instructions. This warranty
is extended only to the original retail purchaser, when proof of purchase is provided.

This warranty covers only the cost of parts and labor required to restore the product to proper operating condition.
Transportation and incidental costs associated with warranty repairs are not reimbursable under this warranty.

Warranty service is available only through authorized dealers and service centers.

This warranty does not cover defects resulting from misuse, abuse, negligence, accidents, lack of proper maintenance,
normal wear, alteration, modification, tampering, contaminated fuels, repair using improper parts, or repair by anyone other
than an authorized dealer or service center. Routine maintenance is the responsibility of the owner.

THIS EXPRESS WARRANTY IS GIVEN IN LIEU OF ANY OTHER WARRANTY EITHER EXPRESSED OR
IMPLIED, INCLUDING WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR-
POSE.

DESA International assumes no responsibility for indirect, incidental or consequential damages. Some states do not allow
the exclusion or limitation of incidental or consequential damages, or limitations or exclusions may not apply to you. This
Limited Warranty gives you specific legal rights and you may also have other rights which vary from state to state.

WARRANTY AND REPAIR SERVICE

LIMITED WARRANTY

KEEP THIS WARRANTY

This warranty does not cover discoloration due to operation of heater. We reserve the right to amend these specifications
at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty,
expressed or implied.

WARRANTY SERVICE

Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be pre-
sented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so,
DESA International will repair or replace the heater without charge.

REPAIR SERVICE

Return your heater to your nearest authorized service center. Repairs not covered by the warranty will be billed at
standard prices. Each Service Center is independently owned and operated. We reserve the right to amend these specifi-
cations at any time without notice.

2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004

Model

Serial No.

Date of Purchase

Summary of Contents for RCP275

Page 1: ...COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PRO VIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION AND OR CARBON MONOXIDE POISONING ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUC TIONS MANUAL LABEL...

Page 2: ...WARNING NOT FOR HOME OR RECREATIONAL VEHICLE USE The heater is designed for use as a construction heater The primary purpose of construction heaters is to provide temporary heating of buildings under construc tion alteration or repair and to provide temporary emergency heat Properly used the heater provides safe economical heating Products of combustion are vented into the area being heated We can...

Page 3: ...Keep heater away from strong drafts water spray rain or dripping water Never attach duct work to heater Neverblockairinlet bottomofshell orairoutlet aroundtopofshell ofheater Keep children and animals away from heater Locate heater on stable and level surface if heater is hot or operating Minimum heater clearances from combustibles Sides 4 feet Top 6 feet 2 inches Install and use heater with care ...

Page 4: ...KING Figure 1 Product Identification Shell Top Thermocouple Pilot Automatic Control Valve Inlet Connector Base Hose Regulator Assembly Note Debris Shield Not Shown THEORY OF OPERATION The Fuel System The hose regulator assembly attaches to the propane gas supply This provides fuel to the heater The Ignition System The piezo ignitor lights the pilot fuel supply The pilot fuel supply is lit manually...

Page 5: ...e needed in colder weather Your local propane gas dealer will help you select the proper supply system Average Temperature F At Tank Location 60 40 32 20 10 0 Number Of Tanks 2 2 3 3 3 3 SPECIFICATIONS Rating BTU Hr Fuel Fuel Consumption Gallons Hour Pounds Hour Supply Pressure To Regulator Maximum Minimum for input adjustment Regulator Outlet Pressure Weight Pounds Shipping Weight Pounds Size L x...

Page 6: ...nting down Pointing vent down protects regulator from weather damage Supply Valve POL Fitting Hose Regulator Vent pointing down 3 Connect hose to the inlet connector Tighten firmly using 9 16 wrench IMPORTANT Use extra hose or piping if needed Install extra hose or piping between hose regulator assembly and propane tank You must use the regulator supplied with heater even if propane tank has one H...

Page 7: ... heater To Start Heater 1 Follow all installation ventilation and safety information 2 Locate heater on stable and level surface Make sure strong drafts do not blow on heater WARNING Fully close main burner valve before lighting pilot If not severe burns can occur Do this by turning valve handle towards the OFF position until it stops 3 Open propane supply valve on propane tank s slowly Note If no...

Page 8: ...ers over three high if more than one heater is being stored Secure heaters with rope or strap after stacking 1 Store propane tank s in safe manner Refer to Chapter 5 of Standard for Storage and Handling of Liquified Petroleum Gases ANSI NFPA 58 Follow all local codes Always store propane tanks outdoors 2 Place plastic cover caps over brass fittings on inlet connector and hose regulator assembly 3 ...

Page 9: ...al minutes to purge air with automatic control valve button depressed 4 Replace pilot orifice 5 Adjust ignitor electrode gap to 120 Check wire lead for damage Replace piezo ignitor and or ignitor electrode as necessary 1 Relight hold automatic control valve button in 45 seconds 2 Check propane tank s for proper gas supply 3 Tighten connection or replace thermocouple 4 Replace automatic control val...

Page 10: ...uest along with a self addressed stamped envelope to the address listed on the back page of this manual Be sure to include the model number of the heater SERVICE PUBLICATION Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s either contact your nearest Parts Central or call DESA International s Technical Service Department at 1 800 323 ...

Page 11: ...11 099156 NOTES ...

Page 12: ...NCLUDING WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PUR POSE DESA International assumes no responsibility for indirect incidental or consequential damages Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations or exclusions may not apply to you This Limited Warranty gives you specific legal rights and you may also have other right...

Reviews: