background image

124434-01
Rev. A
09/08

NOT A UPC

124434 01

DESA Heating, LLC

2701 Industrial Drive
Bowling Green, KY 42101
www.desatech.com
1-866-672-6040

WARRANTY

kEEP ThIS WARRANTY

DESA hEATINg, LLC LIMITED WARRANTIES

New Products

Standard Warranty:

 DESA Heating, LLC warrants this new product and any parts thereof to be free from 

defects in material and workmanship for a period of one (1) year from the date of first purchase from an 

authorized dealer provided the product has been installed, maintained and operated in accordance with 

DESA Heating, LLC’s warnings and instructions.

For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from 

the date of first purchase.

Factory Reconditioned Products

Limited Warranty:

 DESA Heating, LLC warrants factory reconditioned products and any parts thereof 

to be free from defects in material and workmanship for 30 days from the date of first purchase from an 

authorized dealer provided the product has been installed, maintained and operated in accordance with 

DESA Heating, LLC’s warnings and instructions.

Terms Common to All Warranties

The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under 
this warranty the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, 

and only when installed by a qualified installer in accordance with all local codes and instructions furnished 

with this product.

This warranty covers the cost of part(s) required to restore this product to proper operating condition and 
an allowance for labor when provided by a DESA Heating, LLC Authorized Service Center or a provider 
approved by DESA Heating, LLC. Warranty parts must be obtained through authorized dealers of this prod

-

uct and/or DESA Heating, LLC who will provide original factory replacement parts. Failure to use original 

factory replacement parts voids this warranty.
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty 
repairs, unless expressly covered by this warranty, are not reimbursable under this warranty and are the 
responsibility of the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, 
improper installation, lack of proper maintenance, tampering, or alteration(s).

This is DESA Heating, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty 

excludes any and all other warranties, express or implied, written or verbal and limits the duration of any 

and all implied warranties, including warranties of merchantability and fitness for a particular purpose to one 
(1) year on new products and 30 days on factory reconditioned products from the date of first purchase. 
DESA Heating, LLC makes no other warranties regarding this product.
DESA Heating, LLC’s liability is limited to the purchase price of the product, and DESA Heating, LLC shall 

not be liable for any other damages whatsoever under any circumstances including indirect, incidental, or 

consequential damages.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of 

incidental or consequential damages, so the above limitation or exclusion may not apply to you. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 

For information about this warranty contact:

Model (

located on product or identification tag

) _____________________________

Serial No. (

located on product or identification tag

) __________________________

Date Purchased  __________________________

Keep receipt for warranty verification.

Summary of Contents for MAEF26

Page 1: ...the optional accessories listed in these in structions Use of optional accessories not specifically tested for this heater could void the heater warranty and or result in a safety hazard This firepla...

Page 2: ...illows bedding papers clothes and curtains away from front of heater 3 This heater is hot when in use To avoid burns do not let bare skin touch hot surfac es The grill directly in front of heater outl...

Page 3: ...age 12 for other trim options and cause a risk of fire However if you have to use an extension cord the cord should be No 14AWG minimum size and rated not less than 1875 WATTS 17 Always use ground fau...

Page 4: ...s Heater Flame Ember Backlight Power Figure 2 Product Identification Product Identification Heat Vents ON OFF Power Button Log Front Glass Back Glass Heater Button Flame Button Ember Button Backlight...

Page 5: ...cated 120 volt grounded outlet CAUTION The unit s power supply cord must be connected to a properly grounded and pro tected 120 volt outlet Always use ground fault protection where required by the ele...

Page 6: ...ireplace for wiring it is best to hire a professional to do this step in order to prevent personal injury To reduce the risk of fire do not run the power cord under rugs carpets etc Arrange the power...

Page 7: ...unded outlet 4 Push fireplace insert so that the trim is against the finished mantle or wall sur face Notice When the front is installed it will cover the gap betweentheheaterandframing cabinet finish...

Page 8: ...ill shut off when room reaches ap proximately 86 F 30 C Medium will shut off when room reaches approximately 79 F 26 C Low will shut off when room reaches ap proximately 72 F 22 C Note Fanonheaterwill...

Page 9: ...er Blower 1 Remove screws from around top panel of firebox see Figure 10 2 There are several wires attached to the top panel Carefully lift top panel 3 Disconnect heater blower wires from main circuit...

Page 10: ...nd discard transformer 5 Place new transformer against inside of firebox surround and replace screws removed in step 3 6 Reconnect transformer wires to control board see Wiring Diagram page 12 7 Repla...

Page 11: ...back screen Glass 1 The glass is cleaned in the factory dur ing assembly During shipment instal lation handling etc the glass surface may collect dust particles These can be removed by buffing lightly...

Page 12: ...ITE D Syn MOTOR LED V33 MODEL MF500 REMOTE SENSOR THERMOSTAT LED EMBER STRIP LED BACKLIGHT STRIP TRANSFORMER 120V 60HZ 12V 12V 700MA TF1 TF P N F801 0015 9000 Rev A 26 32 36 FIREPLACE MAIN CONTROL BOA...

Page 13: ...switch by turning main power switch off and waiting 5 minutes then turning it back on or reset circuit breaker 1 Inspect wiring for loose connections 2 Call a qualified service techni cian to replace...

Page 14: ...www desatech com 124434 01A 14 1 17 5 6 7 5 19 13 8 9 4 10 12 11 2 18 3 14 15 16 20 Parts Model MAEF26...

Page 15: ...20 120927 29 Top stainless steel 1 PARTS AVAILABLE NOT SHOWN 120927 17 Wire Flame Effect 1 120927 18 Wire Ember Bed 1 120927 19 Wire Backlight 1 120927 23 Thermocouple 1 Replacement Parts Note Use onl...

Page 16: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...