4
1. This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases.
2. Do not place propane/LP supply tank(s) inside
any structure. Locate propane/LP supply tank(s)
outdoors (propane/LP units only).
3. If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use
any phone in your building
• immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions
• if you cannot reach your gas supplier, call the
fire department
4. This heater shall not be installed in a bedroom
or bathroom, unless installed as a vented appli
-
ance. See
Installing Damper Clamp Accessory
for Vented Operation
, page 11.
5. Before installing in a solid fuel burning
fireplace, the chimney flue and firebox must
be cleaned of soot, creosote, ashes and loose
paint by a qualified chimney cleaner. Creosote
will ignite if highly heated. A dirty chimney
flue may create and distribute soot within
the house. Inspect chimney flue for damage.
If damaged, repair flue and firebox before
operating heater.
6. Do not burn solid-fuel in a masonry or UL127
factory-built fireplace in which a vent-free
room heater is installed.
7. If fireplace has glass doors, never operate this
heater with glass doors closed. If you operate
heater with doors closed, heat buildup inside fire
-
place will cause glass to burst. Make sure there
are no obstructions across opening of fireplace.
8. To prevent the creation of soot, follow the instruc
-
tions in Cleaning and Maintenance
, page 21.
9. Before using furniture polish, wax, carpet
cleaner, or similar products, turn heater off.
If heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls and furniture.
10. This heater needs fresh, outside air ventilation
to run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff system.
The ODS shuts down the heater if enough fresh
air is not available. See
Air for Combustion and
Ventilation,
page 5. If heater keeps shutting off,
see Troubleshooting,
page 23.
11. Do not run heater
• where flammable liquids or vapors are used
or stored
• under dusty conditions
12. Do not use this heater to cook food or burn paper
or other objects.
13. Do not use heater if any part has been exposed
to or under water. Immediately call a qualified
service technician to inspect the room heater and
to replace any part of the control system and any
gas control which has been under water.
14. Do not operate heater if any log is broken. Do
not operate heater if a log is chipped (dime-
sized or larger).
15. Turn heater off and let cool before servicing,
installing, or repairing. Only a qualified service
person should install, service, or repair heater.
16. Operating heater above elevations of 4,500
feet may cause pilot outage.
17. To prevent performance problems, do not
use propane/LP fuel tank of less than 100 lb.
capacity (propane/LP units only).
18. Provide adequate clearances around air
openings.
LOCAL CODES
Install and use heater with care. Follow all local
codes. In the absence of local codes, use the lat
-
est edition of The National Fuel Gas Code ANSI
Z223.1/NFPA 54
*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note:
Where listed vented decorative logs are
required, thermostat operation is not permitted.
SAFETy INFORMATION
Continued
State of Massachusetts: The installa-
tion must be made by a licensed plumber
or gas fitter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.