www.desatech.com
15
107902-01L
CLEANING
WARNING: Turn off heater
and let cool before cleaning.
CAUTION: You must keep
control areas, burner and circu
-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a
qualified service person. Heater
may need more frequent clean
-
ing due to excessive lint from
carpeting, bedding material, pet
hair, etc.
WARNING: Failure to keep
the primary air opening(s) of
the burner(s) clean may result in
sooting and property damage.
ODS/PILOT AND BURNER
Use a vacuum cleaner, pressurized air or
small, soft bristled brush to clean.
BURNER PILOT AIR INLET
The primary air inlet holes allow the proper
amount of air to mix with the gas. This pro-
vides a clean burning flame. Keep these holes
clear of dust, dirt and lint. Clean these air inlet
holes prior to each heating season. Blocked
air holes will create soot. We recommend that
you clean the unit every three months during
operation and have heater inspected yearly
by a qualified service person.
We also recommend that you keep the burner
tube and pilot assembly clean and free of dust
and dirt. To clean these parts we recommend
using compressed air no greater than 30 PSI.
Your local computer store, hardware store or
home center may carry compressed air in a
can. If using compressed air in a can, please
follow the directions on the can. If you don't
follow directions on the can, you could dam-
age the pilot assembly.
1. Shut off the unit, including the pilot. Allow
the unit to cool for at least thirty minutes.
2. Inspect burner, pilot for dust and dirt.
3. Blow air through the ports/slots and holes
in the burner.
4. Never insert objects into the pilot tube.
Figure 24 - Pilot Air Inlet Hole
Pilot Assembly
Pilot Air Inlet
CABINET
Air Passageways
Use pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap
and water mixture. Wipe the cabinet to re-
move dust.
SPECIFICATIONS
GWRP10
• 5,500/10,000 Btu/hr (Variable)
• Propane/LP Gas
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure (inches of water):
Maximum - 14" WC, Minimum - 11" WC
GWRN10
• 5,500/10,000 Btu/hr (Variable)
• Natural Gas
• Piezo Ignition
• Pressure Regulator Setting: 6" W.C.
• Inlet Gas Pressure (inches of water):
Maximum - 10.5" WC, Minimum - 7" WC
Clean the pilot assembly also. A yellow tip on
the pilot flame indicates dust and dirt in the
pilot assembly. There is a small pilot air inlet
about 2" from where the pilot flame comes out
of the pilot assembly (see Figure 24). With
the unit off, lightly blow air through the air
inlet. You may blow through a drinking straw
if compressed air is not available.