![background image](http://html1.mh-extra.com/html/desa/gw30b/gw30b_installation-instructions-manual_2485632005.webp)
-4 -
For more information, visit www.desatech.com
TOGGLE SWITCH CONNECTION
The installation of a toggle switch in this appliance allows you
to activate the gas control valve without the use of normal
household electricity. The valve operates on millivolt current
supplied by the heat generated from the sensor on the
thermopile. Refer to Surround Attachment for installing the
surround.
1. To swing down louver assembly. First pull on the upper
spring latches towards the inside of louver assembly. The
spring latches are located at each corner of the louver
assembly as shown in the preceding figure.
2. Connect the 18 GA. wires from the gas control valve to
the TOGGLE SWITCH located at the upper right corner
of the surround as shown in the figure below. (Wires and
toggle switches are supplied with the appliance).
3. The wires must be routed through the lower right side of
the insert, through both electric bushings of the insert (one
at the lower right side and the other towards the top), and
finally connected to the top toggle switch.
4. The bottom toggle switch is for the optional blower. The
wires for the blower are routed the same way as the wires
for the gas control valve. Refer to the wiring diagram on
page xx for connecting the wires to the blower.
NOTE: If any of the original wire supplied must be replaced,
use type 18 AWG-105 deg. C (25 ft. length maximum) or
equivalent.
MANTEL CLEARANCE
TOP VIEW OF FIREPLACE
BOTTOM LOUVER
GAS CONTROL VALVE
CAUTION
: Do not wire this millivolt system wall switch
to a regular 120v AC wiring.
TOGGLE SWITCH LOCATION