background image

3

901915

OWNER’S MANUAL

PRODUCT
IDENTIFICATION

Figure 1 - Product Identification (HFVMR24 Shown)

OPTIONAL
PRODUCT
FEATURES

ON/OFF SAFETY VALVE/
PILOT KIT AND PROPANE/LP
CONVERSION

An optional valve/safety pilot kit with a
piezo ignitor is available for this appliance.
This system requires no matches, batteries,
or other sources to light. You must use this
optional system for LP conversion. See Ac-
cessories
, page 13.

REMOTE CONTROL READY
(MILLIVOLT) SAFETY VALVE/
PILOT KIT

An optional millivolt valve/safety pilot kit
with a piezo ignitor is available for this
appliance. This system requires no matches,
batteries, or other sources to light. This
system may be connected to a wall switch or
hand-held wireless remote control. See Ac-
cessories
, page 13.

REMOTE CONTROL
ACCESSORIES

There is an optional hand-held ON/OFF
remote control that can be purchased sepa-
rately for this log set. You must use the
millivolt valve/safety pilot kit to use remote
accessories with this appliance. See Acces-
sories
, page 13.

A wall switch is also available for this
appliance. You must use the millivolt valve/
safety pilot kit to use the wall switch with
this appliance. See Accessories, page 13.

UNPACKING

 CAUTION: Do not remove the

metal data plates from the burner
pan. The data plates contain im-
portant product information.

1.

Remove logs, hearth kit, pan materials,
and hardware from carton.

2.

Remove all protective packaging ap-
plied to logs and base for shipment.

3.

Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought the product.

LOCAL CODES

Install and use log set with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code, ANS Z223.1
, also known as NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY  10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA  02269

Grate

Burner
Pan

Burner
Manifold

Right Side
Burner

Left
Side
Burner

Hearth Kit Model: _____________________________________

Serial Number: _______________________________________

Log Set Model:  HFVMR18 or HFVMR24

Burner Inlet
Fitting

Summary of Contents for Comfort Glow RGA 2-72

Page 1: ...l for correct installation and operational procedures For assistance or additional information consult a qualified installer service agency or the gas supplier WARNING This appliance is for installati...

Page 2: ...ashes and loose paint by a qualified chimney cleaner Creosote will ignite if highly heated Inspect chimney flue for damage 5 You must operate this log set with a fire placescreeninplace Makesurefirepl...

Page 3: ...appliance See Acces sories page 13 A wall switch is also available for this appliance Youmustusethemillivoltvalve safety pilot kit to use the wall switch with this appliance See Accessories page 13 U...

Page 4: ...Side 65 000 55 000 8 dia Btu Input Natural Gas Btu Input Propane Gas Minimum Vent Opening MINIMUM FIREBOX SIZES LOG FRONT BACK SIZE WIDTH WIDTH DEPTH HEIGHT 18 28 28 16 18 24 29 3 4 29 3 4 16 18 Add 6...

Page 5: ...below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection adjustable crescent wrench or pliers sediment trap tee joint pipe wrench CAUTION Use on...

Page 6: ...6 Make sure the burner ports face downward 3 Using thread sealant resistant to the ac tion of propane LP gas on larger end of fitting screw the burner inlet fitting through hole and into burner manifo...

Page 7: ...Flame Adjustment Adjust the flame ON OFF by turning the gas shutoff valve counterclockwise to open or clockwise to close as necessary Shutting Off Appliance Turn gas shutoff valve clockwise to the OF...

Page 8: ...Log set is smoking sooting excessively Note It is natural and unavoidable for vented gas log sets to produce moderate levels of carbon soot where flames contact the logs This is especially true with p...

Page 9: ...ED PROBLEM Log Set produces a clicking ticking noise just after burner is lit or shut off Log Set produces unwanted odors Gas odor even when control knob is in OFF position Gas odor during combustion...

Page 10: ...10 901915 VENTED NATURAL GAS LOGS ILLUSTRATED PARTS BREAKDOWN HFVMR18 HFVMR24 3 6 12 10 11 10 4 7 9 5 1 8 2...

Page 11: ...atural Gas 1 4 901064 10 901064 03 Natural Gas Injector 1 5 901763 02 901763 01 Burner Manifold 1 6 901767 02 901767 01 Burner Pan 1 7 901242 01 901242 01 Damper Clamp Std Assembly 1 8 901232 01 90123...

Page 12: ...eplacement Parts on page 13 of this manual KEY PART NUMBER FOR NO 18 24 DESCRIPTION QTY 1 901656 01 901657 01 Bottom Front 1 2 2 901666 01 901667 01 Bottom Front 2 2 3 901619 01 901619 01 FS 12Y Top L...

Page 13: ...n For all models Use for firebox decoration nly SILICA SAND GA9850 Not Shown For all models Use for firebox decoration only Carton of 6 LAVA ROCK GA6067 Not Shown For all models Use for firebox decora...

Page 14: ...aol com Master Parts Dist 1251 Mound Ave NW Grand Rapids MI 49504 2672 616 791 0505 1 800 446 1446 Fax 616 791 8270 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO A...

Page 15: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 16: ...related to repairing a defective log set will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND A...

Reviews: