background image

16

107064

UNVENTED PROPANE/LP GAS FIREPLACE

LFP33PRA

O

F

F

PIL

OT

O

N

L O

I H

AUTO
ON
OFF

LIGHTING

INSTRUCTIONS

 WARNING: You must operate

this fireplace with the fireplace
screen in place. Make sure fire-
place screen is installed before
running fireplace.

NOTICE: During initial operation
of new fireplace, burning logs will
give off a paper-burning smell.
Open damper or window to vent
smell. This will only last a few hours.

1.

STOP! Read the safety information,
column 1.

2.

Make sure equipment shutoff valve
is fully open.

3.

Set switch in OFF position.

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

FOR YOUR SAFETY

READ BEFORE

LIGHTING

OPERATING
FIREPLACE

 WARNING: Burners will come

on automatically within one
minute when the selector switch
is in the ON position after the
pilot is lit.

Figure 37 - Control Knob and Ignitor Button Location (Shown as Supplied,
No Control Options)

Control Knob

Ignitor Button

 Selector Switch in OFF Position

Flame Adjustment
Knob

4.

Press in and turn control knob clock-
wise 

  to the OFF position.

5.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, column 1. If you don’t
smell gas, go to the next step.

6.

Press in and turn control knob coun-
terclockwise  

  to the PILOT

position. Press in control knob for
five (5) seconds (see Figure 37).

Note:

 You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds or more. This will al-
low air to bleed from the gas system.

7.

With control knob pressed in, press
and release ignitor button. This will
light pilot. The pilot is attached to the
front burner. If needed, keep press-
ing ignitor button until pilot lights.

Note:

 If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure
 on page 17.

8.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
• If control knob does not pop out

when released, contact a qualified
service person or gas supplier for
repairs.

Note:

 If pilot goes out, repeat steps

4 through 8.

9.

Slightly push in and turn control
knob counterclockwise 

 to the

ON position.

10. Wait one minute and switch selector

switch to the ON position to light
burner.

11. Set flame adjustment knob to any

level between HI and LO.

 CAUTION: Do not try to adjust

heating levels by using the
manual shutoff valve.

Summary of Contents for Comfort Glow LFP33PRA

Page 1: ...justment alteration ser vice ormaintenancecancause injury or property damage Re fer to this manual for correct installationandoperationalpro cedures For assistance or ad ditional information consult a...

Page 2: ...instructions in Cleaning and Main tenance page 18 9 Before using furniture polish wax car pet cleaner or similar products turn heater off If heated the vapors from these products may create a white p...

Page 3: ...top corners of the fireplace screen Remove and discard these screws Lift fireplace screen up and pull out to remove 3 Remove protective packaging applied to logs log base assembly and fireplace 4 Chec...

Page 4: ...Unusually Tight Construction Theairthatleaksarounddoorsandwindows mayprovideenoughfreshairforcombustion and ventilation However in buildings of PRODUCT FEATURES OPERATION This vent free fireplace is...

Page 5: ...____ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual am...

Page 6: ...rovide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors orspacesopentotheoutdoors Thesespaces include attics and crawl s...

Page 7: ...crews two adjust ing plates with set screws and two shims in the hardware packet 3 Align shim under adjusting plate as shown in Figure 5 4 Slide one end of adjusting plate shim in slot on mitered edge...

Page 8: ...earth top to run flexible gas line to fireplace see Figure 8 Make sure to locate access hole so cabi net mantel will cover it when installed Note You can secure base to floor us ing wood screws Counte...

Page 9: ...see Acces sories pages 24 and 25 3 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local codes after the equipment shutoff valve The fl...

Page 10: ...ling fireplace make sure you have the items listed below external regulator supplied by installer piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connec...

Page 11: ...t is resistant to liquid pe troleum LP gas We recommend that you install a sediment trap in supply line as shown in Figure 17 Locate sediment trap where it is within reach for cleaning Install in pipi...

Page 12: ...con nected 3 Pressurize supply piping system by ei ther using compressed air or opening propane LP supply tank valve 4 Check all joints of gas supply piping system Apply mixture of liquid soap and wat...

Page 13: ...ure the front of the middle log is resting on the tabs of the grate base and the cutout area is cen tered over the burner U bend 2 Locate pegs on the bottom of back log 2 Slide these pegs into the hol...

Page 14: ...f re mote control unit following direction of arrow 2 Insert twoAAAbatteries following dia gram in battery housing area 3 Replace battery cover onto remote con trol unit Figure 31 Installing Battery i...

Page 15: ...he battery Place battery into the battery housing 3 Replace battery cover onto remote con trol unit Figure 36 Installing Battery in Hand Held Remote Control Unit Battery Cover 9 Volt Battery Terminal...

Page 16: ...or loss of life FOR YOUR SAFETY READ BEFORE LIGHTING OPERATING FIREPLACE WARNING Burnerswillcome on automatically within one minute when the selector switch is in the ON position after the pilot is li...

Page 17: ...ies pages 24 and 25 Follow instructionsincludedwiththeremotecontrol Figure 38 Pilot Ignitor Electrode Pilot Burner After lighting let pilot flame burn for about one minute Turn control knob to ON posi...

Page 18: ...cool Either remove blockage or replace burner Blocked burner flame holes will create soot CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount...

Page 19: ...ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor to base panel of log set Nut is located behind base panel 4 Replace ign...

Page 20: ...irements page 4 1 Turn control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local pro pane LP gas company 3 Observe minimum...

Page 21: ...statement above 1 Improper log placement 2 Drafts or other air currents affecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked OBSERVED PROBLEM Fireplace produces a c...

Page 22: ...ay be low When Gas Quality Is Bad pilot will not stay lit burners will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is bad If so contact your l...

Page 23: ...514 0322 1 800 397 7553 203 248 7553 Parts Department Portable Heater Parts 342 N County Rd 400 East Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 sales portableheaterparts com techs...

Page 24: ...ERIMETER BRASS TRIM Not Shown GMC36F Series Walnut Finished Birch Veneer GMC37U Series Unfinished Birch Veneer Ready to Stain or Paint Space saving corner mantels feature mold ings fluting and medalli...

Page 25: ...erated in a manually or thermostatically controlled mode Youcanturnthegaslogheateronand off without ever leaving the comfort of your easy chair BRASS TRIM ACCESSORY GA7090 Not Shown Optional with buil...

Page 26: ...NVENTED PROPANE LP GAS FIREPLACE LFP33PRA ILLUSTRATED PARTS BREAKDOWN REMOTE READY MODEL LFP33PRA 20 30 O F F P I L O T O N H I L O 11 15 29 10 9 7 6 5 1 2 4 3 8 12 7 17 16 28 18 19 24 14 13 19 23 22...

Page 27: ...rner Orifice Injector 1 11 102772 01 Burner 2 12 M11084 38 Screw 8 x 38 2 13 104236 01CK Painted Base Assy 1 14 M12461 26 Screw 10 x 32 4 15 104238 01CK Firebox Bottom 1 16 103284 03 Wiring Harness 1...

Page 28: ...28 107064 UNVENTED PROPANE LP GAS FIREPLACE LFP33PRA 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13 ILLUSTRATED PARTS BREAKDOWN FIREPLACE LFP33PRA...

Page 29: ...K Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CK Firebox Wrapper 1 9 103412 01CK Louver Door 1 10 101727 02 Screen Assembly 1 11 101348 01 Firebox Support 2 12 103207 0...

Page 30: ...elated to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY AND ALL...

Reviews: