background image

8

104275

PROPANE/LP GAS HEATER

INSTALLATION

Continued

Installing Two Mounting Screws

Note:

 Wall anchors and mounting screws

are in hardware package. The hardware pack-
age is provided with heater.

Attaching to Wall Stud Method

For attaching mounting screw to wall stud

1.

Drill hole at marked location using 9/64"
drill bit.

2.

Insert mounting screw into wall stud.

3.

Tighten screw until 1/16" space (thick-
ness of penny) is between screwhead
and wall.

Attaching to Wall Anchor Method

Follow instructions below to attach mount-
ing screws to hollow walls (wall areas be-
tween studs) or solid walls (concrete or
masonry).

1.

Drill holes at marked locations using
5/16" drill bit. For solid walls (concrete
or masonry), drill at least 1 

1

/

4

" deep.

2.

Fold wall anchor (see Figure 6).

3.

Insert wall anchor (wings first) into
hole. Tap anchor flush to wall.

4.

For thin walls (1/2" or less), insert red
key into wall anchor. Push red key to
“pop” open anchor wings (see Figure 7).

IMPORTANT:

 Do not hammer key! For

thick walls (over 1/2" thick) or solid
walls, do not pop open wings.

5.

Tighten two screws until 1/16" space
(thickness of penny) is between
screwheads and wall (see Figure 8).

Figure 6 - Folding Anchor

Thin Walls (1/4" to 1/2" thick)

Figure 7 - Popping Open Anchor Wings
For Thin Walls

Figure 11 - Installing Bottom Mounting
Screw

1/16" Space

Thin or
Thick Wall
(thick wall
shown)

Solid
Wall

Figure 8 - Tightening Anchors

Placing Heater on Mounting
Screws

1.

Locate two keyhole slots on back panel
of heater (see Figure 9).

2.

Place large openings of slots over
screwheads. Slide heater down until
screws are in small portion of slots.

Removing Front Panel of Heater

1.

Remove two screws near bottom cor-
ners of front panel.

2.

Lift straight up on grill guard until it stops.
Grill guard will slide up about 1/4".

3.

Pull bottom of front panel forward, then
down.

Figure 9 - Location Of Keyhole Slots On
Back Panel Of Heater

Keyhole Slots

Figure 10 - Removing Front Panel Of
Heater

Installing Bottom Mounting
Screw

1.

Locate bottom mounting hole. This
hole is near bottom on back panel of
heater (see Figure 11).

2.

Mark screw location on wall.

3.

Remove heater from wall.

4.

If installing bottom mounting screw
into hollow or solid wall, install wall
anchor. Follow steps 1 through 5 un-
der Attaching To Wall Anchor Method.

If installing bottom mounting screw
into wall stud, drill hole at marked lo-
cation using 9/64" drill bit.

5.

Replace heater on wall.

6.

Insert bottom anchor screw through
back panel into bottom anchor or drilled
hole (see Figure 11).

7.

Tighten screw until heater is firmly se-
cured to wall. Do not over tighten.

Note:

 Do not replace front panel at this

time. Replace front panel after making
gas connections and checking for leaks
(see pages 9 and 10).

Summary of Contents for Comfort Glow CGP10RLA

Page 1: ...alified installer service agency or the gas supplier WARNING This is an unvented gas firedheater Itusesair oxy gen from the room in which it is installed Provisions for ad equate combustion and venti...

Page 2: ...ts controls can be dan gerous 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases 2 Do not place propane LP s...

Page 3: ...plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Ox...

Page 4: ...y iftherearedoorlesspassagewaysorventila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecom...

Page 5: ...raws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can...

Page 6: ...23 1 Section5 3 AirforCombustionand Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controll...

Page 7: ...nstalling heater next to vinyl or cloth wall coverings or operating heater where impurities such as to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may disco...

Page 8: ...11 Installing Bottom Mounting Screw 1 16 Space Thin or Thick Wall thick wall shown Solid Wall Figure 8 Tightening Anchors Placing Heater on Mounting Screws 1 Locate two keyhole slots on back panel of...

Page 9: ...pple Ground Joint Union From External Regulator 11 W C to 14 W C Pressure Equipment Shutoff Valve Sediment Trap Test Gauge Connection 3 Minimum Installsedimenttrapinsupplylineasshown in Figure 13 Loca...

Page 10: ...1 Disconnect appliance with its appliance maingasvalve controlvalve andequip ment shutoff valve from gas supply pip ingsystem Pressuresinexcessof1 2psig will damage heater regulator 2 Cap off open end...

Page 11: ...This will light pilot The pilot is attached to the front of burner If needed keep pressingignitorbuttonuntilpilotlights Ignitor Electrode WARNING When running heater set control knob at LOW or HIGH lo...

Page 12: ...r small soft bristled brush to clean CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500 hours of operation or every three months WARNING Turn off heater and let coo...

Page 13: ...his prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace...

Page 14: ...polish wax carpet cleaners or similar products POSSIBLE CAUSE 1 Burner orifice s is clogged 2 Burner orifice s diameter is too small 3 Inlet gas pressure is too low 1 Manifold pressure is too low 2 Bu...

Page 15: ...paint hair spray glues etc see IMPORTANT statement above 2 Low fuel supply 3 Gas leak SeeWarning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partia...

Page 16: ...s Pressure Is Too Low pilot will not stay lit burner s will have delayed ignition heater will not produce specified heat propane LP gas supply may be low When Gas Quality Is Bad pilot will not stay li...

Page 17: ...616 791 8270 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 www washerparts com East Coast Energy Products 707 Broadway W Long Branch NJ 07764 1542...

Page 18: ...18 104275 PROPANE LP GAS HEATER ILLUSTRATED PARTS BREAKDOWN CGP10RLA 7 2 7 1 ODS PILOT 19 18 17 16 15 14 13 10 12 9 9 11 20 7 8 6 6 5 4 3 2 1 21 22 23 23 A B...

Page 19: ...Thermocouple 1 7 2 098594 01 Ignitor Electrode 1 8 099884 02 Burner Assembly 1 9 099056 01 Injector 2 10 099390 02 Tubing Valve to plaque A 1 11 099387 05 Pilot Tubing Valve to pilot 1 12 099392 01 Tu...

Page 20: ...n Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF...