A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

CHECKING GAS
CONNECTIONS

 WARNING: Test all gas pip-

ing and connections for leaks
after installation or servicing.
Correct all leaks at once.

Figure 15 - Checking Gas Joints

Figure 14 - Equipment Shutoff Valve

Equipment
Shutoff
Valve

Open

Propane/LP
Supply Tank

Equipment
Shutoff
Valve

Control Valve Location

Closed

Pressure Testing Gas Supply
Piping System

Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)

1.

Disconnect appliance with its appliance
main gas valve (control valve) and equip-
ment shutoff valve from gas supply pip-
ing system. Pressures in excess of 1/2 psig
will damage heater regulator.

2.

Cap off open end of gas pipe where
equipment shutoff valve was connected.

3.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

4.

Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

6.

Reconnect heater and equipment
shutoff valve to gas supply. Check re-
connected fittings for leaks.

Test Pressures Equal To or Less Than 1/2
PSIG (3.5 kPa)

1.

Close equipment shutoff valve (see Fig-
ure 14).

 CAUTION: Make sure exter-

nal regulator has been installed
between propane/LP supply and
heater. See guidelines under

 Con-

necting to Gas Supply, page 9.

 WARNING: Never use an open

flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. Bubbles forming show
a leak. Correct all leaks at once.

2.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

3.

Check all joints from propane/LP sup-
ply tank to equipment shutoff valve (see
Figure 15). Apply mixture of liquid
soap and water to gas joints. Bubbles
forming show a leak.

4.

Correct all leaks at once.

Pressure Testing Heater Gas
Connections

1.

Open equipment shutoff valve (see Fig-
ure 14).

2.

Open propane/LP supply tank valve.

3.

Make sure control knob of heater is in
the OFF position.

4.

Check all joints from equipment shutoff
valve to control valve (see Figure 15).
Apply mixture of liquid soap and wa-
ter to gas joints. Bubbles forming show
a leak.

5.

Correct all leaks at once.

6.

Light heater (see Operating Heater,
pages 10 and 11). Check all other in-
ternal joints for leaks.

7.

Turn off heater (see To Turn Off Gas
To Appliance
, page 11).

8.

Replace front panel.

INSTALLATION

Continued

Summary of Contents for Comfort Glow CGP10RLA

Page 1: ...alified installer service agency or the gas supplier WARNING This is an unvented gas firedheater Itusesair oxy gen from the room in which it is installed Provisions for ad equate combustion and venti...

Page 2: ...ts controls can be dan gerous 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases 2 Do not place propane LP s...

Page 3: ...plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Ox...

Page 4: ...y iftherearedoorlesspassagewaysorventila tion grills between them WARNING This heater shall notbeinstalledinaconfinedspace or unusually tight construction unless provisions are provided foradequatecom...

Page 5: ...raws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used _________________ Btu Hr maximum the space can...

Page 6: ...23 1 Section5 3 AirforCombustionand Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controll...

Page 7: ...nstalling heater next to vinyl or cloth wall coverings or operating heater where impurities such as to bacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may disco...

Page 8: ...11 Installing Bottom Mounting Screw 1 16 Space Thin or Thick Wall thick wall shown Solid Wall Figure 8 Tightening Anchors Placing Heater on Mounting Screws 1 Locate two keyhole slots on back panel of...

Page 9: ...pple Ground Joint Union From External Regulator 11 W C to 14 W C Pressure Equipment Shutoff Valve Sediment Trap Test Gauge Connection 3 Minimum Installsedimenttrapinsupplylineasshown in Figure 13 Loca...

Page 10: ...1 Disconnect appliance with its appliance maingasvalve controlvalve andequip ment shutoff valve from gas supply pip ingsystem Pressuresinexcessof1 2psig will damage heater regulator 2 Cap off open end...

Page 11: ...This will light pilot The pilot is attached to the front of burner If needed keep pressingignitorbuttonuntilpilotlights Ignitor Electrode WARNING When running heater set control knob at LOW or HIGH lo...

Page 12: ...r small soft bristled brush to clean CLEANING BURNER PILOT AIR INLET HOLE We recommend that you clean the unit ev ery 2 500 hours of operation or every three months WARNING Turn off heater and let coo...

Page 13: ...his prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Replace ignitor 2 Replace...

Page 14: ...polish wax carpet cleaners or similar products POSSIBLE CAUSE 1 Burner orifice s is clogged 2 Burner orifice s diameter is too small 3 Inlet gas pressure is too low 1 Manifold pressure is too low 2 Bu...

Page 15: ...paint hair spray glues etc see IMPORTANT statement above 2 Low fuel supply 3 Gas leak SeeWarning statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partia...

Page 16: ...s Pressure Is Too Low pilot will not stay lit burner s will have delayed ignition heater will not produce specified heat propane LP gas supply may be low When Gas Quality Is Bad pilot will not stay li...

Page 17: ...616 791 8270 www nbmc com Washer Equipment Co 1715 Main Street Kansas City MO 64108 2195 KS MO AR 816 842 3911 www washerparts com East Coast Energy Products 707 Broadway W Long Branch NJ 07764 1542...

Page 18: ...18 104275 PROPANE LP GAS HEATER ILLUSTRATED PARTS BREAKDOWN CGP10RLA 7 2 7 1 ODS PILOT 19 18 17 16 15 14 13 10 12 9 9 11 20 7 8 6 6 5 4 3 2 1 21 22 23 23 A B...

Page 19: ...Thermocouple 1 7 2 098594 01 Ignitor Electrode 1 8 099884 02 Burner Assembly 1 9 099056 01 Injector 2 10 099390 02 Tubing Valve to plaque A 1 11 099387 05 Pilot Tubing Valve to pilot 1 12 099392 01 Tu...

Page 20: ...n Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED BY THE LAW OF...

Reviews: