background image

14

103414

UNVENTED PROPANE/LP GAS FIREPLACE

CGFP28P and CGFP28PT

20"

24

1

/2

"

27

1

/2

"

30"

2

 

1/2

"

6"

8"

10"

Propane
Supply Tank

External Regulator

Vent Pointing Down

Figure 30 - External Regulator With Vent
Pointing Down

 CAUTION: Use only new,

black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of 1/2"
diameter or greater to allow
proper gas volume to fireplace. If
pipe is too small, undue loss of
pressure will occur.

 CAUTION: Use pipe joint seal-

ant that is resistant to liquid pe-
troleum (LP) gas.

Install sediment trap in supply line as shown
in Figure 31, page 15. Locate sediment trap
where it is within reach for cleaning. Locate
sediment trap where trapped matter is not
likely to freeze. A sediment trap traps mois-
ture and contaminants. This keeps them
from going into fireplace gas controls. If
sediment trap is not installed or is installed
wrong, fireplace may not run properly.

Installation must include a manual shutoff
valve, union, and plugged 1/8" NPT tap.
Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from
fireplace (see Figure 31, page 15).

Check your building codes for any special
requirements for locating manual shutoff
valve to fireplaces.

Apply pipe joint sealant lightly to male
threads. This will prevent excess sealant
from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.

INSTALLATION

Continued

Mantel Clearances for Built-In
Installation

If placing mantel above built-in fireplace,
you must meet minimum clearance between
mantel shelf and top of fireplace opening.

Figure 29 - Minimum Mantel Clearances
for Built-In Installation

Mantel Shelf

INSTALLING GAS PIPING TO
FIREPLACE LOCATION

NOTICE: A qualified service per-
son must connect fireplace to
gas supply. Follow all local codes.

 CAUTION: Never connect

heater directly to the propane
supply. This heater requires an
external regulator (not supplied).
Install the external regulator be-
tween the heater and propane
supply.

Installation Items Needed

Before installing fireplace, make sure you
have the items listed below.

• external regulator (supplied by installer,

see Figure 30)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• manual shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

• approved flexible gas line with gas con-

nector (if allowed by local codes) (not
provided)

*  An A.G.A. design-certified manual shutoff
valve with 1/8" NPT tap is an acceptable
alternative to test gauge connection. Pur-
chase the optional A.G.A. design-certified
manual shutoff valve from your dealer. See
Accessories, page 32.

The installer must supply an external regu-
lator. The external regulator will reduce
incoming gas pressure. You must reduce
incoming gas pressure to between 11 and 14
inches of water. If you do not reduce incom-
ing gas pressure, heater regulator damage
could occur. Install external regulator with
the vent pointing down as shown in Figure
30. Pointing the vent down protects it from
freezing rain or sleet.

If your installation does not meet the above
minimum clearances, you must:

• raise the mantel to an acceptable height,

OR

• remove the mantel.

Note:
All Vertical
measurements
are from top of
fireplace
opening to
bottom of
mantel shelf.
All measure-
ments are in
inches.

Summary of Contents for Comfort Glow CGFP28P

Page 1: ...or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury or property damage Re fer to this manual for correct installationandoperationalpro ce...

Page 2: ...ld fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 9 This fireplace is des...

Page 3: ...les on the bottom tray Lift the carton off the fire box Remove packing 2 Locate two screws above top corners of the fireplace screen Remove and discard these screws Lift fireplace screen up and pull o...

Page 4: ...fuel burning appli ances in your home buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceiling...

Page 5: ...Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of B...

Page 6: ...nto adjoining room see op tion 3 Figure 3 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts Figure 4...

Page 7: ...in reach of a 120 volt grounded electrical out let orinstallanelectricaloutletwithinreach of the blower power cord For built in in stallation an outlet accessory GA3555 is available see Accessories pa...

Page 8: ...lign the holes in top mounting tabs of blower with holes in wall of wrapper see Fig ure 9 Using two 8 screws provided mount blower and tighten screws firmly 5 Route terminals end of power cord through...

Page 9: ...Wire Green Wire Black Wire White Wire Blue Wire To Switch and Cover Assembly Figure 14 Wiring Diagram If any of the original wire as supplied with the appliance must be replaced it must be replaced w...

Page 10: ...et aside noting the prop erly mounted location of each 3 Remove screws that attach log base as sembly to fireplace Carefully lift up log base assembly and remove from fire place takingcaretopullflexib...

Page 11: ...r the power cord will exit the left side or the right side of the firebox In stall 1 plastic bushing provided into the 1 5 hole in the floor support bracket on the exit side see Figure 19 Install the...

Page 12: ...antel Make sure all pieces fit prop erly Remove mantel 5 Mark floor and base or wall for gas line entrance Make sure there is enough clearance between heater and mantel for gas line IMPORTANT Make sur...

Page 13: ...6 17 3 4 Continued Figure 26 Rough Opening for Installing in Wall 1 Frame in rough opening Use dimen sions shown in Figure 26 for the rough opening If installing in a corner use dimensions shown in Fi...

Page 14: ...mumclearancebetween mantel shelf and top of fireplace opening Figure 29 Minimum Mantel Clearances for Built In Installation Mantel Shelf INSTALLING GAS PIPING TO FIREPLACE LOCATION NOTICE A qualified...

Page 15: ...ea Reattach log base assembly to fireplace with screws removed in step 2 NOTICE Most building codes do not permit concealed gas con nections A flexible gas line is provided to allow accessibility from...

Page 16: ...e see Fig ure 34 2 Open propane supply tank valve 3 Make sure control knob of fireplace is in the OFF position 4 Check all joints from manual shutoff valve to thermostat gas valve see Fig ure 35 Apply...

Page 17: ...4 Figure 36 Installing Rear Log Figure 39 Installing Top Log Figure 40 Installing Fireplace Screen WARNING You must operate this fireplace with the fireplace screen in place Make sure fire place scre...

Page 18: ...ng the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on...

Page 19: ...uding near the floor If you smell gas STOP Follow B in the safety in formation above If you don t smell gas go to the next step Figure 43 Control Knob and Ignitor But ton Location Ignitor Button Contr...

Page 20: ...replace off see To Turn Off Gas to Appliance page 18 Thermostat con trolled models or column 1 this page Manually controlled models see Troubleshooting pages 22 through 24 Figure 48 Incorrect Front Bu...

Page 21: ...center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the direc tions on the can If you don t follow direc tionso...

Page 22: ...ich allows thermocouple to cool causing pilot flame to go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple dam...

Page 23: ...ter a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed from line Have gas line checked by lo cal propane gas company 3 Obse...

Page 24: ...h fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas l...

Page 25: ...Portable Heater Parts 342 N County Rd 400 E Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Parts Department FBD 1349 Adams St Bowling Green KY 42103 3414 502 846 1199 1 800 654 8534 F...

Page 26: ...AS FIREPLACE CGFP28P and CGFP28PT ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY VARIABLE MANUALLY CONTROLLED MODEL CGFP28P 27 8 9 8 8 19 13 12 8 6 3 4 1 2 7 7 1 7 2 10 18 23 16 11 26 14 6 6 6 6 21 15...

Page 27: ...1 06 Ignitor Cable 1 14 103410 01CK Firebox Bottom 1 15 098867 10 Gas Regulator 1 16 101004 01 Front Burner Injector 1 17 102445 01 Piezo Ignitor 1 18 101007 01 Crossover Tube 1 19 099387 05 Pilot Tub...

Page 28: ...LP GAS FIREPLACE CGFP28P and CGFP28PT ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY THERMOSTAT CONTROLLED MODEL CGFP28PT 18 6 27 8 9 8 8 19 13 12 3 4 1 2 7 7 1 7 2 10 16 11 26 14 5 6 6 6 6 22 25 23 1...

Page 29: ...acket 1 10 101330 05 Front Burner Assembly 1 11 100999 02 Rear Burner Assembly 1 12 102257 08CJ Base Assembly 1 13 098271 06 Ignitor Cable 1 14 103410 01CK Firebox Bottom 1 15 098867 10 Gas Regulator...

Page 30: ...30 103414 UNVENTED PROPANE LP GAS FIREPLACE CGFP28P and CGFP28PT ILLUSTRATED PARTS BREAKDOWN FIREPLACE 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13 CGFP28P CGFP28PT...

Page 31: ...8 01CK Right Front Side 1 4 102759 01CK Left Front Side 1 5 101514 01CK Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CJ Firebox Wrapper 1 9 103412 01CK Louver Door 1 10...

Page 32: ...ries MediumStainedOak Veneer Mantel features moldings fluted sides and medallion Available in walnut finished or unfinishedhardwood readytostainorpaint Shown with optional base accessory Dimensions H...

Page 33: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 34: ...costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY A...