background image

19

103414

OWNER’S MANUAL

IGNITOR

Continued

OPERATING
FIREPLACE

Continued

THERMOSTAT

CONTROL

OPERATION

1.

Follow steps 1 through 5 under Light-
ing Instructions
, page 18.

2.

Depress control knob and light pilot
with match.

3.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, page 18.

MANUAL LIGHTING

PROCEDURE

Variable Manually-Controlled
Model CGFP28P

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

 WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

FOR YOUR SAFETY

READ BEFORE

LIGHTING

You can set the thermostat control knob
to any comfort level between HI and LO.
The thermostat will gradually modulate
the heat output and flame height from
higher to lower settings, or pilot, in order
to maintain the comfort level you select.
The ideal comfort setting will vary by
household depending upon the amount
of space to be heated, the output of the
central heating system, etc.

Note:

 Selecting the HI setting will cause

the burner to remain on without modu-
lating down in most cases.

LIGHTING

INSTRUCTIONS

 WARNING: You must operate

this fireplace with the fireplace
screen in place. Make sure fire-
place screen is installed before
running fireplace.

NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell. Orange flame will also be
present. Open window to vent
smell. Operate fireplace on HI
position to burn off odor. This
will only last a few hours.

1.

STOP! Read the safety information
in previous column.

2.

Make sure manual shutoff valve is
fully open.

3.

Turn control knob clockwise 

Clockwise

to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation above. If you don’t smell
gas, go to the next step.

Figure 43 - Control Knob and Ignitor But-
ton Location

Ignitor Button

Control Knob

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately
call a qualified service technician to
inspect the appliance and to replace
any part of the control system and
any gas control which has been un-
der water.

5.

Slightly depress and turn control knob
counterclockwise 

C-clockwise

 to the PI-

LOT position. Press in control knob for
five (5) seconds (see Figure 43).

Note:

 If running fireplace for first

time, there will be air in gas line. You
may need to press in control knob for
30 seconds or longer. This will allow
air to bleed from the gas system.
• If control knob does not pop out

when released, contact a qualified
service person or gas supplier for
repairs.

6.

Continue pressing control knob in.
Press and release ignitor button. This
will light pilot. The pilot is attached
to the front burner. If needed, keep
pressing ignitor button until pilot
lights.

Note:

 If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure
, page 20.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

 If pilot goes out, repeat steps

3 through 7.

8.

Slightly depress and turn control
knob counterclockwise  

C-clockwise

 to

the HIGH position. Both burners
should light. Set control knob to de-
sired heat setting.

Figure 44 - Pilot

Thermocouple

Ignitor Electrode

Pilot Burner

Summary of Contents for Comfort Glow CGFP28P

Page 1: ...or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury or property damage Re fer to this manual for correct installationandoperationalpro ce...

Page 2: ...ld fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 9 This fireplace is des...

Page 3: ...les on the bottom tray Lift the carton off the fire box Remove packing 2 Locate two screws above top corners of the fireplace screen Remove and discard these screws Lift fireplace screen up and pull o...

Page 4: ...fuel burning appli ances in your home buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceiling...

Page 5: ...Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of B...

Page 6: ...nto adjoining room see op tion 3 Figure 3 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts Figure 4...

Page 7: ...in reach of a 120 volt grounded electrical out let orinstallanelectricaloutletwithinreach of the blower power cord For built in in stallation an outlet accessory GA3555 is available see Accessories pa...

Page 8: ...lign the holes in top mounting tabs of blower with holes in wall of wrapper see Fig ure 9 Using two 8 screws provided mount blower and tighten screws firmly 5 Route terminals end of power cord through...

Page 9: ...Wire Green Wire Black Wire White Wire Blue Wire To Switch and Cover Assembly Figure 14 Wiring Diagram If any of the original wire as supplied with the appliance must be replaced it must be replaced w...

Page 10: ...et aside noting the prop erly mounted location of each 3 Remove screws that attach log base as sembly to fireplace Carefully lift up log base assembly and remove from fire place takingcaretopullflexib...

Page 11: ...r the power cord will exit the left side or the right side of the firebox In stall 1 plastic bushing provided into the 1 5 hole in the floor support bracket on the exit side see Figure 19 Install the...

Page 12: ...antel Make sure all pieces fit prop erly Remove mantel 5 Mark floor and base or wall for gas line entrance Make sure there is enough clearance between heater and mantel for gas line IMPORTANT Make sur...

Page 13: ...6 17 3 4 Continued Figure 26 Rough Opening for Installing in Wall 1 Frame in rough opening Use dimen sions shown in Figure 26 for the rough opening If installing in a corner use dimensions shown in Fi...

Page 14: ...mumclearancebetween mantel shelf and top of fireplace opening Figure 29 Minimum Mantel Clearances for Built In Installation Mantel Shelf INSTALLING GAS PIPING TO FIREPLACE LOCATION NOTICE A qualified...

Page 15: ...ea Reattach log base assembly to fireplace with screws removed in step 2 NOTICE Most building codes do not permit concealed gas con nections A flexible gas line is provided to allow accessibility from...

Page 16: ...e see Fig ure 34 2 Open propane supply tank valve 3 Make sure control knob of fireplace is in the OFF position 4 Check all joints from manual shutoff valve to thermostat gas valve see Fig ure 35 Apply...

Page 17: ...4 Figure 36 Installing Rear Log Figure 39 Installing Top Log Figure 40 Installing Fireplace Screen WARNING You must operate this fireplace with the fireplace screen in place Make sure fire place scre...

Page 18: ...ng the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on...

Page 19: ...uding near the floor If you smell gas STOP Follow B in the safety in formation above If you don t smell gas go to the next step Figure 43 Control Knob and Ignitor But ton Location Ignitor Button Contr...

Page 20: ...replace off see To Turn Off Gas to Appliance page 18 Thermostat con trolled models or column 1 this page Manually controlled models see Troubleshooting pages 22 through 24 Figure 48 Incorrect Front Bu...

Page 21: ...center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the direc tions on the can If you don t follow direc tionso...

Page 22: ...ich allows thermocouple to cool causing pilot flame to go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple dam...

Page 23: ...ter a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed from line Have gas line checked by lo cal propane gas company 3 Obse...

Page 24: ...h fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas l...

Page 25: ...Portable Heater Parts 342 N County Rd 400 E Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Parts Department FBD 1349 Adams St Bowling Green KY 42103 3414 502 846 1199 1 800 654 8534 F...

Page 26: ...AS FIREPLACE CGFP28P and CGFP28PT ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY VARIABLE MANUALLY CONTROLLED MODEL CGFP28P 27 8 9 8 8 19 13 12 8 6 3 4 1 2 7 7 1 7 2 10 18 23 16 11 26 14 6 6 6 6 21 15...

Page 27: ...1 06 Ignitor Cable 1 14 103410 01CK Firebox Bottom 1 15 098867 10 Gas Regulator 1 16 101004 01 Front Burner Injector 1 17 102445 01 Piezo Ignitor 1 18 101007 01 Crossover Tube 1 19 099387 05 Pilot Tub...

Page 28: ...LP GAS FIREPLACE CGFP28P and CGFP28PT ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY THERMOSTAT CONTROLLED MODEL CGFP28PT 18 6 27 8 9 8 8 19 13 12 3 4 1 2 7 7 1 7 2 10 16 11 26 14 5 6 6 6 6 22 25 23 1...

Page 29: ...acket 1 10 101330 05 Front Burner Assembly 1 11 100999 02 Rear Burner Assembly 1 12 102257 08CJ Base Assembly 1 13 098271 06 Ignitor Cable 1 14 103410 01CK Firebox Bottom 1 15 098867 10 Gas Regulator...

Page 30: ...30 103414 UNVENTED PROPANE LP GAS FIREPLACE CGFP28P and CGFP28PT ILLUSTRATED PARTS BREAKDOWN FIREPLACE 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13 CGFP28P CGFP28PT...

Page 31: ...8 01CK Right Front Side 1 4 102759 01CK Left Front Side 1 5 101514 01CK Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CJ Firebox Wrapper 1 9 103412 01CK Louver Door 1 10...

Page 32: ...ries MediumStainedOak Veneer Mantel features moldings fluted sides and medallion Available in walnut finished or unfinishedhardwood readytostainorpaint Shown with optional base accessory Dimensions H...

Page 33: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 34: ...costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY A...

Reviews: