UNVENTED PROPANE/LP GAS FIREPLACE

CGFP28P and CGFP28PT

42"

16"

Figure 23 - Placing Hearth Base Acces-
sory Against Wall

Figure 22 - Location of Nailing Flanges

Nailing
Flanges

INSTALLATION

Continued

INSTALLATION
CLEARANCES

Note: Clearances are the same if
using optional cabinet mantel or built-
in installation.

  WARNING: Maintain the mini-

mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining wall.

Carefully follow the instructions below. This
will ensure safe installation.

Minimum Wall and Ceiling
Clearances (see Figure 21)

A. Clearances from the side of the fire-

place opening to any combustible wall
should not be less than 16 inches for a
cabinet mantel or 12 inches for a cor-
ner installation.

B. Clearances from the top of the fireplace

opening to the ceiling should not be less
than 42 inches.

Note:

 The instructions below show installa-

tion using the GMC11F/GMC12U/
GMC13F series cabinet mantel and the
GC3333F/GC3334U/GC3335F series
hearth base accessories (see Accessories,
page 32). A brass trim kit is included with
each mantel accessory. The hearth base ac-
cessory shown is optional for this installa-
tion. You can install fireplace and cabinet
mantel directly on the floor.

1.

Assemble cabinet mantel, brass trim
kit, and hearth base. Assembly instruc-
tions are included with each accessory.

2.

If installing an optional blower acces-
sory (see Accessories, page 32). Install
a properly grounded 120 volt, three
prong electrical outlet at fireplace lo-
cation if outlet is not there. If possible,
locate outlet so cabinet mantel will
cover it when installed (see Figure 24).

3.

Break off nailing flanges (see Figure
22) with hammer or pliers.

4.

Place mantel and base in desired loca-
tion. Place heater in front opening of
mantel. Make sure all pieces fit prop-
erly. Remove mantel.

5.

Mark floor and base or wall for gas line
entrance. Make sure there is enough
clearance between heater and mantel
for gas line. 

IMPORTANT:

 Make sure

there are no electrical lines where gas
piping will go through floor or wall.

 WARNING: For conventional

installation, it is recommended
you use the cabinet mantel or
hearth base specified in this
manual. Surface clearances may
not be sufficient with other cabi-
net mantels and hearth bases.
This may create a fire hazard. See
Accessories, page 32, for correct
mantels and hearth bases.

CONVENTIONAL FIREPLACE
INSTALLATION

Figure 21 - Minimum Clearance to Wall
and Ceiling

MINIMUM
CLEARANCE
Side Wall - 16 "
Ceiling - 42"
Floor - 0"

Electrical Outlet

Hearth Base

Flexible Gas
Line

Gas Line
Access
Hole

6.

Place hearth base accessory against
wall at installation location. Cut an ac-
cess hole in hearth base top to run flex-
ible gas line to fireplace (see Figure 24).
Make sure to locate access hole so cabi-
net mantel will cover it when installed.

Note:

 You can secure base to floor us-

ing wood screws. Countersink screw
heads and putty over.

7.

Install gas piping to fireplace location.
This installation includes an approved
flexible gas line (if allowed by local
codes) after the manual shutoff valve.
The flexible gas line must be the last
item installed on the gas piping. See In-
stalling Gas Piping to Fireplace Loca-
tion
, page 14.

8.

Carefully place fireplace on top of
hearth base (Figure 24, page 13). Be
careful not to scratch or damage hearth
base. 

Note:

 You can secure fireplace to

hearth or floor. Open louver door. Lo-
cate screw holes in bottom of base.
Secure with wood screws through these
holes and into hearth or floor.

Conventional installation of this fireplace
involves installing fireplace along with the
corner, face, or cabinet mantel and hearth
base accessories against a wall in your home.
Follow the instructions below to install the
fireplace in this manner.

Summary of Contents for Comfort Glow CGFP28P

Page 1: ...or the gas supplier WARNING Improper installa tion adjustment alteration ser vice or maintenance can cause injury or property damage Re fer to this manual for correct installationandoperationalpro ce...

Page 2: ...ld fall into the control area of fireplace 8 You must operate this fireplace with the fireplace screen in place Make sure fireplace screen is in place before run ning fireplace 9 This fireplace is des...

Page 3: ...les on the bottom tray Lift the carton off the fire box Remove packing 2 Locate two screws above top corners of the fireplace screen Remove and discard these screws Lift fireplace screen up and pull o...

Page 4: ...fuel burning appli ances in your home buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceiling...

Page 5: ...Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of B...

Page 6: ...nto adjoining room see op tion 3 Figure 3 Follow the National Fuel Gas Code NFPA 54 ANS Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts Figure 4...

Page 7: ...in reach of a 120 volt grounded electrical out let orinstallanelectricaloutletwithinreach of the blower power cord For built in in stallation an outlet accessory GA3555 is available see Accessories pa...

Page 8: ...lign the holes in top mounting tabs of blower with holes in wall of wrapper see Fig ure 9 Using two 8 screws provided mount blower and tighten screws firmly 5 Route terminals end of power cord through...

Page 9: ...Wire Green Wire Black Wire White Wire Blue Wire To Switch and Cover Assembly Figure 14 Wiring Diagram If any of the original wire as supplied with the appliance must be replaced it must be replaced w...

Page 10: ...et aside noting the prop erly mounted location of each 3 Remove screws that attach log base as sembly to fireplace Carefully lift up log base assembly and remove from fire place takingcaretopullflexib...

Page 11: ...r the power cord will exit the left side or the right side of the firebox In stall 1 plastic bushing provided into the 1 5 hole in the floor support bracket on the exit side see Figure 19 Install the...

Page 12: ...antel Make sure all pieces fit prop erly Remove mantel 5 Mark floor and base or wall for gas line entrance Make sure there is enough clearance between heater and mantel for gas line IMPORTANT Make sur...

Page 13: ...6 17 3 4 Continued Figure 26 Rough Opening for Installing in Wall 1 Frame in rough opening Use dimen sions shown in Figure 26 for the rough opening If installing in a corner use dimensions shown in Fi...

Page 14: ...mumclearancebetween mantel shelf and top of fireplace opening Figure 29 Minimum Mantel Clearances for Built In Installation Mantel Shelf INSTALLING GAS PIPING TO FIREPLACE LOCATION NOTICE A qualified...

Page 15: ...ea Reattach log base assembly to fireplace with screws removed in step 2 NOTICE Most building codes do not permit concealed gas con nections A flexible gas line is provided to allow accessibility from...

Page 16: ...e see Fig ure 34 2 Open propane supply tank valve 3 Make sure control knob of fireplace is in the OFF position 4 Check all joints from manual shutoff valve to thermostat gas valve see Fig ure 35 Apply...

Page 17: ...4 Figure 36 Installing Rear Log Figure 39 Installing Top Log Figure 40 Installing Fireplace Screen WARNING You must operate this fireplace with the fireplace screen in place Make sure fire place scre...

Page 18: ...ng the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on...

Page 19: ...uding near the floor If you smell gas STOP Follow B in the safety in formation above If you don t smell gas go to the next step Figure 43 Control Knob and Ignitor But ton Location Ignitor Button Contr...

Page 20: ...replace off see To Turn Off Gas to Appliance page 18 Thermostat con trolled models or column 1 this page Manually controlled models see Troubleshooting pages 22 through 24 Figure 48 Incorrect Front Bu...

Page 21: ...center may carry com pressed air in a can You can use a vacuum cleaner in the blow position If using com pressed air in a can please follow the direc tions on the can If you don t follow direc tionso...

Page 22: ...ich allows thermocouple to cool causing pilot flame to go out This prob lem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple dam...

Page 23: ...ter a few hours of operation 1 Turn control knob to LO position and let warm up for a minute 2 Operate burners until air is removed from line Have gas line checked by lo cal propane gas company 3 Obse...

Page 24: ...h fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas l...

Page 25: ...Portable Heater Parts 342 N County Rd 400 E Valparaiso IN 46383 9704 All States 219 462 7441 1 800 362 6951 Parts Department FBD 1349 Adams St Bowling Green KY 42103 3414 502 846 1199 1 800 654 8534 F...

Page 26: ...AS FIREPLACE CGFP28P and CGFP28PT ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY VARIABLE MANUALLY CONTROLLED MODEL CGFP28P 27 8 9 8 8 19 13 12 8 6 3 4 1 2 7 7 1 7 2 10 18 23 16 11 26 14 6 6 6 6 21 15...

Page 27: ...1 06 Ignitor Cable 1 14 103410 01CK Firebox Bottom 1 15 098867 10 Gas Regulator 1 16 101004 01 Front Burner Injector 1 17 102445 01 Piezo Ignitor 1 18 101007 01 Crossover Tube 1 19 099387 05 Pilot Tub...

Page 28: ...LP GAS FIREPLACE CGFP28P and CGFP28PT ILLUSTRATED PARTS BREAKDOWN LOG BASE ASSEMBLY THERMOSTAT CONTROLLED MODEL CGFP28PT 18 6 27 8 9 8 8 19 13 12 3 4 1 2 7 7 1 7 2 10 16 11 26 14 5 6 6 6 6 22 25 23 1...

Page 29: ...acket 1 10 101330 05 Front Burner Assembly 1 11 100999 02 Rear Burner Assembly 1 12 102257 08CJ Base Assembly 1 13 098271 06 Ignitor Cable 1 14 103410 01CK Firebox Bottom 1 15 098867 10 Gas Regulator...

Page 30: ...30 103414 UNVENTED PROPANE LP GAS FIREPLACE CGFP28P and CGFP28PT ILLUSTRATED PARTS BREAKDOWN FIREPLACE 1 2 3 4 15 10 11 9 18 6 17 12 16 16 16 7 8 16 16 5 14 16 13 13 13 CGFP28P CGFP28PT...

Page 31: ...8 01CK Right Front Side 1 4 102759 01CK Left Front Side 1 5 101514 01CK Cover 1 6 101784 01 Snap in Magnet 2 7 103411 01CK Louver Hood 1 8 101838 03CJ Firebox Wrapper 1 9 103412 01CK Louver Door 1 10...

Page 32: ...ries MediumStainedOak Veneer Mantel features moldings fluted sides and medallion Available in walnut finished or unfinishedhardwood readytostainorpaint Shown with optional base accessory Dimensions H...

Page 33: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 34: ...costs related to repairing a defective heater will be the responsibility of the owner TOTHEFULLEXTENTALLOWEDBYTHELAWOFTHEJURISDICTIONTHATGOVERNSTHESALEOFTHEPRODUCT THIS EXPRESS WARRANTY EXCLUDES ANY A...

Reviews: