www.desatech.com
102414-01E
6
PARTS LIST
Item Description
Part Number
1
Burner Guard
100911-01
2
Thermocouple
100886-01
3
Regulator with Fuel Gas Connector
LPA 2025
4
Warning Plate (not shown)
101834-02
5
Burner Replacement Kit* (not shown) LPA5050
* Replace burner screens that are worn, split or broken.
HEATER INFORMATION
Btu Input
One Burner
Two Burners
HI
12,000 Btu/Hr 24,000 Btu/Hr
MED
10,000 Btu/Hr 20,000 Btu/Hr
LOW
8,000 Btu/Hr
16,000 Btu/Hr
Length of Operation
20 lb. Propane Tank
36 hours
18 hours
Operating Pressure
Maximum
15 psi
15 psi
Minimum
12 psi
12 psi
3
2
1