background image

OWNER’S OPERATION AND INSTALLATION MANUAL

MODELS: CGP20, CGP20L, AND RP30D

BLUE-FLAME VENT-FREE

PROPANE/LP GAS HEATER

®

Save this manual for future reference.

RP30D

CGP20

CGP20L

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited
by state or local codes.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. (I.E. Installation of this product is

permitted after the manufactured (mobile) home is sited)

This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases.

WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.

— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.

— WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s in-
structions.

• If you cannot reach your gas supplier, call the fire

department.

— Installation and service must be performed by a quali-
fied installer, service agency, or the gas supplier.

WARNING: Improper installation,
adjustment, alteration, service, or
maintenance can cause injury or
property damage. Refer to this
manual for correct installation and
operational procedures. For as-
sistance or additional information
consult a qualified installer, ser-
vice agency, or the gas supplier.

WARNING: This is an unvented
gas-fired heater. It uses air (oxy-
gen) from the room in which it is
installed. Provisions for adequate
combustion and ventilation air
must be provided. Refer to 

Air for

Combustion and Ventilation sec-
tion on page 3 of this manual.

Summary of Contents for CGP20

Page 1: ...apors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building...

Page 2: ...g WARNING ICON G 001 WARNINGS DANGER Carbon monoxide poisoning may lead to death WARNING Anychangetothis heater or its controls can be dan gerous 2 Do not place propane LP supply tank s inside any str...

Page 3: ...space Adjoining rooms are communicating only iftherearedoorlesspassagewaysorventila tion grills between them WARNING This heater shall not be installed in a confined space unless provisions are pro vi...

Page 4: ...gas heater ________ Btu Hr Gas fireplace logs ________ Btu Hr Other gas appliances ____ Btu Hr Total ____ Btu Hr Example Gas water heater 40 000 Btu Hr Vent free heater 20 000 Btu Hr Total 60 000 Btu...

Page 5: ...Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two per manent openings one within 12 of the ceiling and one within 12 of the floor Connect these items...

Page 6: ...onnection see Figure 13 page 9 sediment trap tee joint pipe wrench AnA G A design certified manual shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Pur chase the op...

Page 7: ...nchor method For attaching mounting bracket to hollow walls wall areas between studs or solid walls concrete or masonry 1 Drill holes at marked locations using 5 16 drill bit For solid walls concrete...

Page 8: ...st gauge hook up NPT tap must be upstream from heater see Figure 13 page 9 Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe...

Page 9: ...em Pressures in excess of 1 2 PSIG will damage heater regulator 2 Cap off open end of gas pipe where manual shutoff valve was connected 3 Pressurize supply piping system by ei ther using compressed ai...

Page 10: ...s appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions ex actly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to...

Page 11: ...flame pattern and burner flame pattern often PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pat tern Figure 19 shows an incorrect pilot flame pattern The incorrect pilot flame is not touchi...

Page 12: ...tionlooseatcon trol valve 5 Pilotflamenottouchingthermocouple which allows thermocouple to cool causing pilot flame to go out This problemcouldbecausedbyoneorboth of the following A Low gas pressure B...

Page 13: ...n heater blocked 4 Dirty or partially clogged burner ori fice Continued REMEDY 1 Contactlocalpropane LPgascompany 2 Clean burner see Cleaning and Main tenance page 15 or replace burner orifice 1 Clean...

Page 14: ...rtially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Notenoughc...

Page 15: ...propane LP gas supply may be low When gas quality is bad pilot will not stay lit burner will produce flames and soot heater will backfire when lit Youmayfeelyourgaspressureistoolowor gas quality is ba...

Page 16: ...placementpartsandaccessories Whencall ing a Parts Central ask for the Parts Depart ment Baltimore Electric 1348 Dixwell Avenue Hamden CT 06514 1 800 397 7553 203 248 7553 Parts Department Portable He...

Page 17: ...AL SHUTOFFVALVE GA5010 For all models Manual shutoff valve with 1 8 NPT tap FLOOR MOUNTING STAND 20 000 Btu Hr Models CGP20L GA4500L Ivory CGP20 GA4500 Earthtone For locating heater on the floor away...

Page 18: ...103569 VENT FREE PROPANE LP GAS HEATER BLUE FLAME CGP20 CGP20L AND RP30D 1 2 4 5 6 7 8 8 9 10 11 12 15 17 19 21 22 23 24 20 27 26 18 14 16 25 3 13 ODS PILOT 10 1 10 2 ILLUSTRATED PARTS BREAKDOWN RP30...

Page 19: ...1 098514 01 Thermocouple 1 10 2 098594 01 Ignitor Electrode 1 11 103447 01 Burner 1 12 099387 05 3 16 Pilot Tubing 1 13 103845 03 Injector 1 14 099066 01 Mounting Bracket 1 15 099415 06 Pressure Regul...

Page 20: ...VENT FREE PROPANE LP GAS HEATER BLUE FLAME CGP20 CGP20L AND RP30D ODS PILOT 12 1 12 2 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 17 19 27 21 23 24 25 26 22 29 28 20 16 18 15 ILLUSTRATED PARTS BREAKDOWN CGP2...

Page 21: ...M5 2 12 099059 04 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 103446 01 Burner 1 14 099387 05 3 16 Pilot Tubing 1 15 103845 01 Injector 1 16 099066 01 Mou...

Page 22: ...____________________________________________ _______________________________________________________________________________________________ ___________________________________________________________...

Page 23: ...___________________ _______________________________________________________________________________________________ ____________________________________________________________________________________...

Page 24: ...is warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance o...

Reviews: