OWNER’S MANUAL

GRH/OV 008

BAD PILOT/LP

INSPECTING
BURNER

Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pat-
tern. Figure 19 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.

GRH/OV 007

GOOD PILOT/LP

Thermocouple

Pilot Burner

Figure 18 - Correct Pilot Flame Pattern

If pilot flame pattern is incorrect, as shown
in Figure 19

• turn heater off (see To Turn Off Gas

to Appliance, page 10)

• see  Troubleshooting, pages 12

through 14

Thermocouple

Pilot Burner

Figure 19 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 20 shows a correct burner flame
pattern. Figure 21 shows an incorrect burner
flame pattern. The incorrect burner flame
pattern shows yellow tipping of the flame. It
also shows the flame higher than 1/2 the
glass panel height.

NOTICE: Do not mistake orange
flames with yellow tipping. Dust
or other fine particles enter the
heater and burn causing brief
patches of orange flame.

 WARNING: If yellow tipping

occurs, your heater could pro-
duce increased levels of carbon
monoxide. If burner flame pat-
tern shows yellow tipping, follow
instructions at bottom of this
page.

CLEANING AND
MAINTENANCE

ODS/PILOT AND BURNER
ORIFICE

• Use a vacuum cleaner, pressurized

air, or small, soft bristled brush to
clean.

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized

air to clean.

Exterior

• Use a soft cloth dampened with a

mild soap and water mixture. Wipe
the cabinet to remove dust.

 WARNING: Turn off heater

and let cool before cleaning.

 CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
bedding material, etc.

Figure 20 - Correct Burner Flame Pattern

1/2 GLASS HEIGHT

INCORRECT FLAME PATTERN

AT HIGH POSITION

CORRECT FLAME PATTERN

AT HIGH POSITION

1/2 GLASS HEIGHT

Figure 21 - Incorrect Burner Flame Pattern

Yellow Tipping

If burner flame pattern is incorrect, as shown
in Figure 21

• turn heater off (see To Turn Off Gas

to Appliance, page 10)

• see  Troubleshooting, pages 12

through 14

Summary of Contents for CFP1000BT

Page 1: ...ne Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion must be provided Refer to page 3 of this manual This a...

Page 2: ... or drafty areas 6 This heater needs fresh outside air ven tilation to run properly This heater has an oxygen depletion sensor ODS pi lot light safety system The ODS shuts down the heater if not enough fresh air is available See Air for Combustion and Ventilation pages 3 through 5 7 Keep all air openings in the front and bottom of heater clear and free of de bris This will insure enough air for pr...

Page 3: ...n ever New materials increased insulation and new construction methods help reduce heat loss in homes Home own ers weather strip and caulk around windows and doors to keep the cold air out and the warm air in During heating months home owners want their homes as airtight as pos sible While it is good to make your home energy efficient your home needs to breathe Fresh air must enter your home All f...

Page 4: ...lume of space 50 cu ft Maximum Btu Hr the space can sup port Example 2304 cu ft volume of space 50 cu ft 46 1 or 46 100 maximum Btu Hr the space can sup port 3 Add the Btu Hr of all fuel burning ap pliances in the space Vent free heater _________ Btu Hr Gas water heater ________ Btu Hr Gas furnace ____________ Btu Hr Vented gas heater ________ Btu Hr Gas fireplace logs________ Btu Hr Other gas app...

Page 5: ...door into adjoining room see op tion 3 Figure 2 Follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation for required size of ventilation grills or ducts Figure 3 Ventilation Air from Outdoors Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by ...

Page 6: ...ative to test gauge connection The optional A G A design certified manual shutoff valve can be purchased from your dealer See Accessory page 15 LOCATING HEATER This heater is designed to be mounted on a wall WARNING Maintainthemini mumclearancesshowninFigure 4 Ifyoucan providegreaterclear ances from floor ceiling and joining wall WARNING Never install the heater in a bathroom in a recreational veh...

Page 7: ...s and wall see Figure 8 ANCHOR 1 16 Space Thin or Thick Wall thick wall shown Solid Wall Installing Bottom Mounting Screw 1 Locate bottom mounting hole This hole is near bottom on back panel of heater see Figure 11 2 Mark screw location on wall 3 Remove heater from wall 4 If installing bottom mounting screw into hollow or solid wall install wall anchor Follow steps 1 through 5 under Attaching To W...

Page 8: ... rain or sleet CAUTION Never connect heater directly to the propane LP supply This heater requires an external regulator not supplied Install the external regulator be tween the heater and propane LP supply Propane LP Supply Tank Figure 12 External Regulator With Vent Pointing Down Vent Pointing Down External Regulator Installsedimenttrapinsupplylineasshown in Figure 13 Locate sediment trap where ...

Page 9: ...heck all joints from manual shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and wa ter to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater page 9 and 10 Check the rest of the internal joints for leaks 7 Turn off heater see To Turn Off Gas to Appliance page 10 8 Replace front panel ON POSITION OFF POSITION Figure 14 Man...

Page 10: ...efer to Troubleshooting pages 12 through 14 Also contact a qualified service person or gas supplier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob If control knob does not pop up when released contact a qualified service person ...

Page 11: ...heater and burn causing brief patches of orange flame WARNING If yellow tipping occurs your heater could pro duce increased levels of carbon monoxide If burner flame pat tern shows yellow tipping follow instructions at bottom of this page CLEANING AND MAINTENANCE ODS PILOT AND BURNER ORIFICE Use a vacuum cleaner pressurized air or small soft bristled brush to clean CABINET Air Passageways Use a va...

Page 12: ...ng A Low gas pressure B Dirty or partially clogged ODS pilot 7 Thermocouple damaged 8 Control valve damaged REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Tighten nut holding piezo ignitor to heater cabinet Nut is located inside heater cabinet at top 6 Replace ignitor cable 7 Replace piezo ignitor...

Page 13: ... Have gas checked by local propane LP gas company 3 Observe minimum installation clear ances see Figure 4 page 6 4 Clean burner see Cleaning and Main tenance page 11 or replace burner ori fice POSSIBLE CAUSE 1 Burner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Manifold pressure is too low 2 Burner orifice is clogged 1 Burner orifice is clogged or dam...

Page 14: ... noise is excessive contact qualified ser vice person 1 Ventilate room Stop using odor causing products while heater is running 2 Refill supply tank 3 Locate and correct all leaks see Check ing Gas Connections page 9 1 Open window and or door for ventila tion 2 Contact local propane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 11 1 Locate and correct all leaks see Check ing G...

Page 15: ...ed this product If they cannot sup ply original replacement part s call DESA International s Technical Service Depart ment at 1 800 323 5190 for referral infor mation When contacting your dealer or DESA International have ready your name and address model number of your heater how heater was malfunctioning type of gas used propane LPor natu ral gas purchase date Usually we will ask you to return t...

Page 16: ...16 102393 PROPANE LP GAS HEATER BLUE FLAME 10 000 BTU 12 2 12 1 ODS PILOT ILLUSTRATED PARTS BREAKDOWN 10 12 11 1 2 3 4 5 6 7 9 8 10 13 14 15 16 17 18 23 24 27 14 22 20 26 25 19 25 21 VP1000BT ...

Page 17: ...098352 03BR Deflector Unit 1 10 098271 03 Ignitor Cable 1 11 098249 01 Nut M5 2 12 099059 03 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 098594 01 Ignitor Electrode 1 13 099386 02 Burner 1 14 099387 11 Pilot Tubing 1 15 098251 07 Injector 1 16 099463 01 Injector Holder 1 17 099415 02 Pressure Regulator 1 18 102863 01 Burner Tubing 1 19 102864 01 Regulator Tubing 1 20 102492 01 5 16 Mal...

Page 18: ...__________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________________________________________________________...

Page 19: ...____________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ ___________________________________________________________________________________________...

Page 20: ...iswarranty Theheater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail orbecomedamagedasaresultofmisuse accidents lackofpropermaintenanceordefectscausedbyimproperinstallation Travel diagnostic cost labor tra...

Reviews: