background image

www.desatech.com

108998-01E

5

Control 
Shaft

Control Knob

Lock Nut

Speed 
Control 
Bracket

Lower Louver

Hearth Pan 
Flange

Bottom Front Refractory

Lower 
Flange

Pre-Installed 
Bracket 
(Direct-Vent 
Only)

Figure 7 - Attaching Speed Control to 

Direct-Vent Firebox

Control 
Knob

Control 
Shaft

Lock Nut

MODELS WITh STAMPED PANEL 
LOUVERS

Wood, B-Vent and Vent-Free Models

1.  Position speed control bracket by inserting 

flange of bracket between hearth pan and up-

per flange of louver opening, then seat bottom 

end of bracket onto lower flange of louver 

opening (see Figure 8).

2.  Mount speed control box by placing plastic 

control shaft through bottom hole on speed 

control bracket. Top screw head on control box 

will fit inside top hole on bracket (see Figure 

8). Secure speed control to bracket with lock 

nut by pushing and turning lock nut with pliers 

clockwise until it is tight against bracket.

3.  Remove knockout plug from louver panel by 

depressing top and bottom retaining clips (see 

Figure 1, page 2).

4.  Place louver panel, louvers pointing up, back 

into framed opening. Align control shaft with 

rectangular opening by sliding control bracket 

along flange (see Figure 8).

5.  Fully seat louver panel into frame opening by 

gently pressing along ends until all dimpled 

retainers have snapped in place.

6.  Place control knob, provided, onto control 

shaft (see Figure 8).

Speed 
Control

Bottom Rear 
Refractory

3.   Place the blower against the lower rear wall 

of the firebox outer wrapper with the exhaust 

port  directed  upward  and  the  thermodisc 

positioned up near the fireplace bottom. The 

thermodisc must be oriented near the fireplace 

bottom as shown in Figure 6 in order to sense 

temperature and properly operate. The blower 

will be held in position against the back wall 

by the magnets incorporated onto the blower 

housing (see Figure 6, page 4).

4.   Be certain that all wire terminals are securely 

attached to terminals on blower motor and 

thermal switch, and that the screw for the 

thermodisc bracket and green ground wire is 

tight.

5.   To mount speed controls, see 

Mounting Speed 

Control for All Direct Vent Models

 (below), 

Mounting Speed Control for All Models with 

Panel Louvers

 (column 2) or 

Mounting Speed 

Control for All Models with Stamped Face 

Louvers

 (page 5), depending on your model.

Mounting sPeed 

Control

DIRECT-VENT MODELS

1.  Mount the speed control box by placing the 

plastic  control  shaft  forward  through  the 

mounting opening on the pre-installed bracket 

(see Figure 7).

2.  While supporting the speed control in the 

vertical position, secure the control shaft by 

pushing and turning the lock nut with pliers 

until it is tight against the mounting bracket. 

Place control knob provided on the control 

shaft (see Figure 7).

Model BKt wire 

asseMBly

Continued

Figure 8 - Attaching Speed Control to 

Firebox with Panel Louvers Using Speed 

Control Bracket 109892-02

Firebox 
Face

Summary of Contents for BK

Page 1: ...ck Nut 1 11125 8 1 2 Phillips Head Screw 1 101378 01 Thermodisc Switch 100 Limit 1 104902 02 Switch Mounting Bracket 1 109892 01 Speed Control Bracket Stamped Face Models 1 109892 02 Speed Control Bracket Panel Louver Models 1 Tools Required Pliers Phillips Screwdriver Flat Blade Screwdriver If any of these pieces are missing or damaged or if the installation instructions for your fireplace or sto...

Page 2: ...rough the control access cover under the front refractory panel see Figure 1 The lower front louver panel can be removed easily see Removing Louver Panel page 3 for instructions Figure 1 Accessing Blower Compartment Controls Not Shown for Clarity B Vent Wood and Vent Free Models Front Refractory Panel Lower Louver Panel Control Access Cover Knockout Plug Figure 2 Accessing Duplex Electrical Outlet...

Page 3: ...le embossed on the edge of the panel To reinstall place louver into cavity and push gently Direct Vent Models There are two different types of direct vent lou vers spring latch and bullet style clip Spring Latch Remove louver with spring latches by simultaneously pulling both top spring latches toward the center of the appliance until they are disengaged from the locating holes Repeat for bottom s...

Page 4: ...ach and make all connections DO NOT trim excessive length away Just enable enough to make all connections securely Figure 5 Blower Model BK Magnetic Strips Exhaust Port Screw Green Ground Wire Spade Terminals Side View Firebox Bottom Air Flow Direction Blower Installed After Lower Panel Removed Blower Location Magnets Model BK wire assembly Note Speed control switches can not be installed into fil...

Page 5: ...ol shaft see Figure 8 Speed Control Bottom Rear Refractory 3 Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward and the thermodisc positioned up near the fireplace bottom The thermodisc must be oriented near the fireplace bottom as shown in Figure 6 in order to sense temperature and properly operate The blower will be held in position ag...

Page 6: ...peed control to bracket with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against bracket Figure 9 Attaching Speed Control to Firebox with Stamp Faced Louvers B36 and VB36 Models Using Speed Control Bracket 109892 01 Lock Nut Mounting Speed Control Continued 3 Remove knockout plug from louver panel by depressing top and bottom retaining clips see Figure 1 page 2...

Page 7: ...ing knob fully counterclockwise before continuing BKT Model The blower will only run when the speed control knob is in the ON position and the thermal switch senses temperature after the fireplace begins to heat up The blower speed can be adjusted by rotating the control knob To turn off turn knob fully counterclockwise until it clicks off If the blower is ON and has been running with the fireplac...

Page 8: ...108998 01 Rev E 10 05 NOT A UPC 2701 Industrial Drive P O Box 90004 Bowling Green KY 42102 9004 Technical Service Department 1 866 672 6040 www desatech com 108998 01 ...

Reviews: