DERRICK
®
CORP. - MOTOR DATA SHEET
JFS M:\Motor Docs\Pe-s-251.doc (Maintenance)
U:\Motor PDFs\Pe-s-251.pdf (view/print)
DOC# PE-S-251-03
Wire Code
Power
Black, White & Red
Ground
Green
Thermal Switch
Orange & Blue
1800 RPM
MODEL
:
SGX VIBRATOR - 60 HZ - (EXPLOSION PROOF TERMINAL BLOCK STYLE)
Vibrator Model
SGX-215/220-60 SGX-230/240-60 SGX-380/400-60 SGX-440-60 SGX-460/480-60 SGX-575/600-60
Voltage [Volts]
215/220
230/240
380/400 440 460/480
575/600
Phase / Frequency [Hz]
3/60 3/60 3/60 3/60 3/60 3/60
Speed [RPM]
1800 1800 1800 1800 1800 1800
Rated Horsepower [HP]
2.5 2.5 2.5 2.5 2.5 2.5
Current @ Idle / Full
Load [Amps]
4.4 / 8.7
4.1 / 8.2
2.5 / 4.9
2.1 / 4.3
2.0 / 4.1
1.6 / 3.3
Locked Rotor Current
[Amps] / Locked Rotor
Code
34.9 / F
32.6 / F
19.6 / F
17.0 / F
16.3 / F
13 / F
Fuse - Non Delay
[Amps]
25 25 15 12 12 10
Overload protection
[Amps]
10 10 6 5 5 4
Data below is common to all model
SGX-60
vibrators.
Insulation class
Ambient temperature
Operating temperature code
Maximum temperature rise
Duty
Thermal switch rating
Thermal switch type
Thermal switch temperature
Power factor - operations
Efficiency - running
Service Factor
NEMA design
Ingress Protection
Weight
Hazardous location (listed as)
Listing agency
Hazardous location (listed as)
Listing agency
F
55º C
T3C
46º C by Resistance
CONTINUOUS
Pilot Duty 720VA, 110 – 600VAC
Normally Closed
Opens @ 145º C / Closes @ 140º C
99.13
98%
1.0
TENV
IP 56
415 lbs.-(189 kg.) STEEL / 290 lbs.–(132 kg.) ALUMINUM
CLASS 1 GROUPS C,D / CLASS 2 GROUPS E,F,G
UL
EExd IIB T3
DEMKO
NOTE:
Derrick
®
vibrators are fixed load devices with no means of altering the loading or power consumption. Power factor
correction capacitors are not recommended for this motor.
02/11/05
–
Rev.
3 Page
1
of
1
37.7500
9.5000
Summary of Contents for EX