EX, SGX VIBRATOR MOTORS
Safety
The following WARNINGS apply to the bearing replacement procedure. Be sure to read and
understand these WARNINGS
before
proceeding.
WARNING! MOTOR HOUSING BECOMES HOT DURING OPERATION AND
MAY CAUSE SEVERE BURNS. DO NOT TOUCH MOTOR HOUSING DURING
OR IMMEDIATELY AFTER MOTOR HAS BEEN OPERATING.
WARNING! ALL OPERATING AND MAINTENANCE PERSONNEL MUST READ
AND UNDERSTAND ALL SAFETY INFORMATION IN THIS MANUAL BEFORE
WORKING WITH THE EQUIPMENT.
WARNING! HIGH VOLTAGE MAY BE PRESENT. BE SURE FUSED
DISCONNECT SUPPLYING ELECTRIC POWER TO THIS EQUIPMENT IS
OPEN. LOCK OUT AND TAG OUT POWER SUPPLY TO PREVENT
ACCIDENTAL APPLICATION OF POWER WHILE MAINTENANCE AND/OR
ADJUSTMENTS ARE IN PROGRESS.
WARNING! TO PREVENT SERIOUS EYE INJURY OR PERMANENT LOSS OF
VISION, WEAR SAFETY GLASSES DURING THIS PROCEDURE.
Bearing Replacement
The procedure below describes replacing the bearing on one end. Repeat the procedure for the
second bearing.
NOTE! Remove vibrator motor from equipment before performing bearing
replacement (refer to Motor Removal and Installation). Bearings will fail
prematurely if new bearings become contaminated during replacement.
Bearing Removal
The following procedure describes bearing removal for one side of the motor. Repeat the
procedure for bearing at opposite end.
1 -
Using a 5mm hex wrench, remove eight
socket head cap screws securing cover to
bearing housing; support cover as last screw
is removed.
2 -
Remove cover, and remove O-ring using
a dental pick or similar tool. Discard O-ring.