EX, SGX VIBRATOR MOTORS
7 - CAREFULLY
slide heated spacer off
motor shaft.
8 -
Using a 6mm hex wrench, remove six
socket head cap screws (M8-1.25x60)
securing bearing mount to bearing housing.
9 -
Locate two threaded holes that accept
the two M8-1.25x70 socket head jack
screws. Jack screw holes are 180 degrees
apart.
10 - Carefully
thread jack screws into
threaded holes in bearing mount, being
sure to avoid cross-threading.