![DERRICK EX Maintenance & Operation Manual Download Page 34](http://html.mh-extra.com/html/derrick/ex/ex_maintenance-and-operation-manual_2485506034.webp)
EX, SGX VIBRATOR MOTORS
28
01 May 09
Trouble
Possible Cause
Corrective Action
Loose hardware
Check security of all external and internal
hardware. Tighten as required.
Excessive noise
Defective bearing
Replace both bearings in accordance with
Bearing Replacement.
Motor turns too
slowly
Incorrect supply
voltage or line
frequency
Check that supply voltage and line frequency
agree with motor data plate. Frequency must
be within ±1Hz.
No electric power to
one motor
Check that supply voltage is connected to both
motors.
Motors not
synchronized (dual
motors only)
Incorrect electrical
connections
Confirm that electrical connections are in
accordance with the instructions in this section.
* Derrick vibrator motors run with higher surface temperatures than standard industrial motors.
Refer to the maximum temperature rise indicated on the motor data plate attached to the motor
case or the motor data sheet included in this manual.