Page 25 of 43
Version with P.S.C. (Pneumatic filter cleaning system)
To start using the vacuum, turn the switch (
1
) ELECTRIC PANEL POWER SUPPLY to “
I
” and press the
green button (
6
) START VACUUM. To stop the machine, press the red button (
8
) STOP VACUUM.
After a work cycle, it is possible to manually start a cleaning cycle of the filter by pressing the blue button
(
4
) FILTER CLEANING ACTIVATION. It is only possible to start cleaning when the machine is stopped,
however, the electrical control panel must be powered (white indicator light (
3
) PRESENCE OF VOLTAGE
on). Before disconnecting power from the panel, make sure that the green indicator light (
7
)
VACUUMING IN PROGRESS is off and there is no filter cleaning in progress.
Ensure that the direction of rotation of the blower matches the figure below
If the direction of rotation is not correct, insert a screwdriver into the notch inside the plug and reverse
the two poles with a rotation of 180°.
Warning!
Before switching the vacuum cleaner on again, ensure the blower has come to a
complete stop.