36
8
Instructions for the Sequence Controller
8.1 General
The sequence controller can be programmed by using the WEB-Interface or by the inte-
grated numeric keypad, whereby the programming choices on the keypad are more lim-
ited.
The sequence controller can be operated as a stand-alone unit or it can be operated by a
PLC.
8.2 Operating Elements
Figure 11:
Operating Elements
8.2.1 Functional Display (LEDs)
The LED’s located below the display notify the user about the operating status of the se-
quence controller:
Color
Description
Meaning
yellow Power
all voltage are O.K.
blue ready
the sequence controller is ready
green Status
last screw assembly was O.K.
red Status
last screw assembly was not O.K.
Table 14:
LEDs
function keys
functional display
menu- and cursor keys