![Deprag AST11-1 Operating Instruction Booklet Download Page 28](http://html1.mh-extra.com/html/deprag/ast11-1/ast11-1_operating-instruction-booklet_2485169028.webp)
28
7.7.1.2.2 Profinet
Figure 10:
Hardware configuration of Profinet
7.7.1.3 Software
The following modules or UDT's are required to control the AST11 via the Profibus or Pro-
finet:
Module
Name
Description
FB15
AST11
Control module for the AST11 sequence controller
This module must be loaded for each AST11 sequence controller
(with each new instance data block respectively)
DB50
IDB_AST11DP
DB instance for FB15 (e.g. Profibus)
DB51
AST11_Interface
Data module for the interface parameters of FB15
DB52
IDB_AST11PN
DB instance for FB15 (e.g. Profinet)
UDT51
AST11_Control
Data structure of the control signals
UDT52
AST11_State
Data structure of the status signals
UDT53
AST11_Data
Data structure of the screw data
Table 7: Modules and UDT's for the control