Pos. 2
Pos. 3
Pos. 6
Pos. 4
Pos. 1
Pos. 7
Tightening torques series P, type PM,
size 15-40
Pump size
Annchor rod
Air inlet
Air valve
Piston
Centre block
Clamp band
Pos. 1
Pos. 2
Pos. 3
Pos. 4
cover, Pos. 6
Pos. 7
DL15-PM
5 Nm
-
-
6 Nm
2,5 Nm
7 Nm
DL25-PM
10 Nm
50 Nm
8 Nm
70 Nm
2,5 Nm
8 Nm
DL40-PM
25 Nm
50 Nm
8 Nm
90 Nm
2,5 Nm
10 Nm